1.1.7 <strong>FP</strong>10SH<br />

1.1 Table of Relays, Memory Areas and Constants<br />

Item Numbering Function<br />

Relay External input<br />

relay<br />

(X) 8,192 points (X0 to X511F) Turn on or off based on external input.<br />

Memory<br />

area<br />

External output<br />

relay<br />

Internal relay<br />

(* Note 1)<br />

Link relay<br />

(* Note 1)<br />

(Y) 8,192 points (Y0 to Y511F) Externally outputs on or off state.<br />

(R) 14,192 points (R0 to R886F) Relay which turns on or off only within<br />

program.<br />

(L) 10,240 points (L0 to L639F) This relay is a shared relay used for<br />

MEWNET link system.<br />

Timer<br />

(T) 3,072 points If a TM instruction has timed out, , the<br />

(* NNotes 1 andd 2) (T0 ( to T2999/ C3000 to C3071) ) contact t t with ith the th same number b turns t on.<br />

Counter (C)<br />

If a CT instruction has counted up, p, the<br />

(* Notes 1 and 2)<br />

contact t t with ith the th same number b turns t on.<br />

Pulse relay (P) 2,048 points (P0 to P127F) This relay is used to turn on only for one<br />

scan duration programmed with the<br />

OT" and OT# instructions.<br />

Error alarm relay (E) 2,048 points (E0 to E2047) If turned on while the unit is running,<br />

this relay stores the history in a dedicated<br />

buffer.<br />

Program this relay so that it is turned on<br />

at the time of abnormality.<br />

Special internal<br />

relay<br />

External input<br />

relay<br />

External output<br />

relay<br />

(R) 176 points (R9000 to R910F) Relay which turns on or off based on<br />

specific conditions and is used as a flag.<br />

(WX) 512 words<br />

(WX0 to WX511)<br />

(WY) 512 words<br />

(WY0 to WY511)<br />

Internal relay (WR) 887 words<br />

(WR0 to WR886)<br />

Link relay (WL) 640 words<br />

(WL0 to WL639)<br />

Data register<br />

(* Note 1)<br />

Link data register<br />

(* Note 1)<br />

Timer/Counter<br />

set value area<br />

(* Note 1)<br />

Timer/Counter<br />

elapsed value area<br />

(* Note 1)<br />

(DT) 10,240 words<br />

(DT0 to DT10239)<br />

(LD) 8,448 words<br />

(LD0 to LD8447)<br />

(SV) 3,072 words<br />

(SV0 to SV3071)<br />

(EV) 3,072 words<br />

(EV0 to EV3071)<br />

File register (FL) 32,765 , words<br />

(* Note 1)<br />

(FL0 to FL32764)<br />

Code for specifying 16 external input<br />

points as one word (16 bits) of data.<br />

Code for specifying 16 external output<br />

points as one word (16 bits) of data.<br />

Code for specifying 16 internal relay<br />

points as one word (16 bits) of data.<br />

Code for specifying 16 link relay points<br />

as one word (16 bits) of data.<br />

Data memory used in program. Data is<br />

handled in 16-bit units (one word).<br />

This is a shared data memory which is<br />

used within the MEWNET link system.<br />

Data is handled in 16-bit units (one<br />

word).<br />

Data memory for storing a target value of<br />

a timer and an initial value of a counter.<br />

Stores by timer/counter number.<br />

Data memory for storing the elapsed value<br />

during operation of a timer/counter.<br />

Stores by timer/ counter number.<br />

Data memoryy used in program. p g Data is<br />

hhandled dl d in i 16-bit 16 bit units it (one ( word). d)<br />