Memory Me areaa<br />

(double word) w (see ee note 4)<br />

Contr trol ins nstructi tion pooint<br />

Constan C ant<br />

Item Number of<br />

points<br />

External input relay<br />

(see note 3)<br />

External output relay<br />

(see note 3)<br />

Internal relay<br />

(see note 2)<br />

Data register<br />

(see note 2)<br />

Timer/counter set<br />

value area<br />

Timer/counter<br />

elapsed value area (see<br />

note 2)<br />

Special data<br />

register<br />

6 double<br />

words<br />

6 double<br />

words<br />

31 double<br />

words<br />

830 double<br />

words<br />

72 double<br />

words<br />

72 double<br />

words<br />

56 double<br />

words<br />

Index register 1 double<br />

words<br />

1.1 Table of Relays, Memory Areas and Constants<br />

Memory area available for use<br />

Matsushita IEC<br />

DWX0−DWX11 %ID0−<br />

%ID11<br />

DWY0−DWY11 %QD0−<br />

%QD11<br />

DWR0−DWR61 %MD0.0−<br />

%MD0.61<br />

DDT0−<br />

DDT1658<br />

%MD5.0−<br />

%MD5.1658<br />

DSV0−DSV142 %MD3.0−<br />

%MD3.142<br />

DEV0−DEV142 %MD4.0−<br />

%MD4.142<br />

DDT9000−<br />

DDT9110<br />

%MD5.9000−<br />

%MD5.9110<br />

Function<br />

Code for specifying 32 external<br />

input points as a double word<br />

(32 bits) of data.<br />

Code for specifying 32 external<br />

output points as double word<br />

(32 bits) of data.<br />

Code for specifying 32 internal<br />

relay points as double word<br />

(32 bits) of data.<br />

Data memory used in a<br />

program. Data is handled in<br />

32-bit units (double word).<br />

Data memory for storing a<br />

target value of a timer and an<br />

initial value of a counter. Stores<br />

by timer/counter number.<br />

Data memory for storing the<br />

elapsed value during operation<br />

of a timer/counter. Stores by<br />

timer/counter number.<br />

Data memory for storing<br />

specific data. Various settings<br />

and error codes are stored.<br />

DI0 %MD6.0 Used as an address of<br />

memory area and constants<br />

modifier.<br />

Item Number of points<br />

Master control relay points (MCR) 32 points<br />

Number of labels (JP and LOOP) 64 labels<br />

Number of step ladders 128 stages<br />

Number of subroutines 16 subroutines<br />

Number of interrupt programs 7 programs (external: 6, internal: 1)<br />

Item Range g available for use<br />

Matsushita IEC<br />

Decimal constants K−32768 to K32767 (for 16-bit operation) −32768 to 32767 (for 16-bit operation)<br />

Hexadecimal<br />

constants<br />

K−2147483648 to K2147483647<br />

(for 32-bit operation)<br />

−2147483648 to 2147483647<br />

(for 32-bit operation)<br />

H0 to HFFFF (for 16-bit operation) 16#0 to 16#FFFF (for 16-bit operation)<br />

H0 to HFFFFFFFF (for 32-bit operation) 16#0 to 16#FFFFFFFF (for 32-bit<br />

operation)<br />

Floating point type F−1.175494×10 −38 to F−3.402823×10 38 −1.17549410E−38 to −3.402823E38<br />

F1.175494×10 −38 to F3.402823×10 38 1.17549410E−38 to 3.402823E38<br />

<strong>CTi</strong> <strong>Automation</strong> - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net<br />

1-5

Hooray! Your file is uploaded and ready to be published.

Saved successfully!