1.1 Table of Relays, Memory Areas and Constants<br />

Item<br />

Numbering<br />

Function<br />

Constant Decimal<br />

constants t t<br />

Hexadecimal<br />

constants t t<br />

Floating g ppoint<br />

ttype pe<br />

Notes<br />

C10/C14<br />

/C16<br />

C32/SL1 T32C<br />

(K) ( ) K−32768 to K32767 (for 16-bit operation)<br />

K−2147483648 to K2147483647 (for 32-bit operation)<br />

(H) ( ) H0 to HFFFF (for 16-bit operation)<br />

H0 to HFFFFFFFF (for 32-bit operation)<br />

(F) F−1.175494×10−38 to F−3.402823×1038 ( )<br />

F1.175494×10 −38 to F3.402823×10 38<br />

1) The points for the timer and counter can be changed by the<br />

setting of system register 5. The numbers given in the table<br />

are the numbers when system register 5 is at its default<br />

setting.<br />

2) There are two unit types, the hold type that saves the<br />

conditions that exist just before turning the power off or<br />

changing form the RUN mode to PROG. mode, and the<br />

non−hold type that resets them. For the <strong>FP</strong>0 T32C, the<br />

selection of hold type and non−hold type can be changed by<br />

the setting of system register. These areas can be spcified as<br />

hold type or non−hold type by setting system register. For the<br />

<strong>FP</strong>0 C10/C14/C16/C32/SL1, that area is fixed and allotted the<br />

numbers as shown below.<br />

Hold type and Non-hold type areas<br />

Item C10/C14/C16 C32/SL1<br />

Timer Non−hold type: All points<br />

Counter Non-hold type From the set value to C139 From the set value to C127<br />

Hold type 4 points (elapsed values) 16 points (elapsed values)<br />

(C140 to C143)<br />

C128 to C143<br />

Internal Non-hold type 976 points<br />

880 points<br />

relay<br />

(R0 to R60F)<br />

(R0 to R54F)<br />

61 words<br />

55 words<br />

(WR0 to WR60)<br />

(WR0 to WR54)<br />

Hold type 32 points (R610 to R62F) 128 points (R550 to R62F)<br />

2 words (WR61 to WR62) 8 words (WR55 to WR62)<br />

Data Non-hold type 1652 words<br />

6112 words<br />

register eg s e<br />

(DT0 to DT1651)<br />

(DT0 to DT6111)<br />

Hold type 8 words<br />

32 words<br />

(DT1652 to DT1659) (DT6112 to DT6143)<br />

<strong>CTi</strong> <strong>Automation</strong> - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net<br />

1-3