2.4.3.1.6 Control of Power Converters<br />

DRAFT<br />

In Figure 2.4.74 the general structure of a power converter is presented. There are three main<br />

components: the Power Part, the Power Converter Control and a Basic I/O-system.<br />

External<br />

Control<br />

System<br />

service and<br />

diagnosis<br />

computer<br />

Backplane with<br />

Interface System, Basic I/O<br />

USB<br />

4 x DAC<br />

Multi<br />

Function<br />

Unit<br />

Remote/Local<br />

Operation<br />

Digital Control<br />

Loop<br />

Graphical<br />

Display<br />

Sequence<br />

Control<br />

Parameters<br />

Monitoring<br />

System<br />

Expansion<br />

if applicable<br />

USI Cascade<br />

USI Control<br />

Possible Expansions<br />

Figure 2.4.74: General structure of power converters<br />

USI 1<br />

USI 2<br />

USI 3<br />

USI 6<br />

ADC Unit<br />

High Speed Acquisition of<br />

up to 4 Analogue Signals<br />

and Protection Circuits<br />

For example:<br />

the load current<br />

Acquisition of up to<br />

4 Analogue Signals<br />

Monitoring and<br />

Protection<br />

Acquisition of up to<br />

8 Digital Signals<br />

and Protection<br />

Control Unit<br />

Pulse Logic for<br />

Power Part<br />

including Protection<br />

Signals for<br />

Circuit Breakers<br />

and Contactors<br />

Further Special<br />

Function Modules<br />

Further Special<br />

Function Modules<br />

Power Converter Control<br />

Fast Analogue Signals<br />

Slow Analogue Signals<br />

Interlock Signals<br />

Firing Pulses<br />

Power Electronic Status Signals<br />

Command Signals<br />

Status Signals<br />

Power<br />

Part<br />

Power Converter<br />

The Power Converter Control is a modular system consisting of a Multifunction unit, an ADC unit<br />

for fast analogue signals and a Control unit. The Multifunction unit is the user interface for manual<br />

operation and service and diagnosis by computer or oscilloscope. It also contains the communication<br />

ports to the external accelerator control system via the basic I/O-unit, and the control loops<br />

and the control topology of the power converter are also implemented in the Multifunction unit.<br />

The ADC unit acquires fast analogue signals of the power part, for example the load current, for<br />

control, protection and documentation purposes.<br />

The Control unit generates command signals and firing pulses for the power electronics of the<br />

power part. Additionally it handles status and interlock signals and slow analogue signals for<br />

protection purposes<br />

As illustrated in Figure 2.4.75 the power converter communicate on a basic digital I/O-level in real<br />

time with a link to the external control system. This link generates the real time data of the set value<br />

for the power converter from data provided by the external control system. Thereby the communication<br />

to the external control system is not in real time. The link mentioned before is an electronic<br />

card which is not part of the power converter. However it can be integrated into the power converter.<br />