yoke. For the purpose of making fiducial references the outer side of the lamination should have a<br />

groove of 20 mm width (±0,02 mm) and 10 mm height which represents to the ideal beam path on<br />

the upper and lower yoke. Furthermore three fit drill-hole in the yoke surfaces, representing precisely<br />

the intersection point of the path tangents and their direction, and some reference planes,<br />

well defined relative to the pole surface, are required.<br />

The reproducibility of the position of the upper and lower yoke among each other after disassembling<br />

and reassembling must be better than 0.050 mm. Reference planes, fit drill-holes and groove<br />

have to be protected against corrosion, but not varnished. Voltage taps are placed along the coil to<br />

detect where a possible quench starts and to measure joint resistances. Voltage and current taps are<br />

connected to the high voltage socket. The wires of the temperature sensors are connected to the low<br />

voltage socket.<br />

Accurate support and stable positioning of the superconducting magnets within their cryostats is<br />

essential for the machine alignment. High flexural stiffness of the supports is therefore the basic<br />

mechanical requirement in order to guarantee that magnets are stable within 0.2 mm under variation<br />

of external forces; respectively the position of the cold mass with respect to cryostat fiducials<br />

should be reproducible to within 0.2 mm.<br />

The cryostat – wherein the magnet must move with - must be capable to be positioned in x, y, z<br />

direction independently, and to be corrected for rotation errors of the magnetic field. Three adjustable<br />

feet should support the cryostat and should provide a controlled motion in the vertical and<br />

horizontal direction. Parameter for the alignment feet are:<br />

• Adjustable range in horizontal / vertical direction: ± 20mm;<br />

• Setting resolution: 0.05 mm;<br />

• Long term stability < 0.1 mm/year;<br />

• Maximum loads on alignment feet: to be customised according to arising overall weight of<br />

cryostat incl. cold mass etc.<br />

The most important tolerances of the quadrupole iron yoke are:<br />

parallelism of contact surfaces ±20 µm<br />

coordinates of pole profile ±20 µm<br />

tolerance of remaining dimensions of lamellas 0.1 mm<br />

tolerance of width of reference groove +20 µm / 0<br />

height of burr at the lamellas max. 0.1 mm<br />

filling factor of yokes 98%<br />

tolerance of weight weight of lamella<br />

flatness of stack 0.1 mm<br />

maximum twist of stack 0.1 mm<br />

maximum height of the bur 0.1 mm<br />