Figure 2.4.29: Assembly of two half-yokes.<br />

Magnetic field measurement<br />

DRAFT<br />

Magnetic field measurements will be made by a Hall probe and a search coil. Driving machines for<br />

the search coil will be used which have similar function as those for the long-coil measurement of<br />

the HICAT dipoles at GSI. The maximum range in radial direction will be 600 mm and the arc<br />

length will be about 4100 mm, see Figure 2.4.30.<br />

Figure 2.4.30: The long-coil driving machine for magnetic field measurements.<br />