DRAFT<br />
For magnets with less stringent field quality requirements (e.g. correctors and steerer magnets<br />
whose field has only to be known in the range of a percent) it is sufficient to monitor the production<br />
randomly by measuring only one or few magnets (see also section 2.4.A5.1). The different measurement<br />
methods foreseen for the different magnets are summarized in Table 2.4.41. The curvature<br />
of the used search coils for the dipoles is given in Table 2.4.42 and the radius of the rotating coil is<br />
given in Table 2.4.43.<br />
Matching Magnet Length<br />
For machines with only a few dipoles and quadrupoles (e.g. 24 pieces) the length of the magnets<br />
has to be matched. For this purpose laminations are inserted at the end of the yoke. The field of the<br />
magnet has to be remeasured after this operation.<br />
Table 2.4.41: Magnetic measurement method to apply for the different magnets.<br />
a) dipoles<br />
field strength field direction field homogeneity centre<br />
CR<br />
NESR<br />
RESR<br />
<strong>Super</strong>-FRS<br />
search coil pole shoes search coil pole shoes<br />
b) quadrupoles / correctors<br />
SIS 300<br />
HESR<br />
SIS 100<br />
CR<br />
NESR<br />
RESR<br />
<strong>Super</strong>-FRS<br />
field strength axis field direction field homogeneity<br />
rotating coil pole shoes rotating coil<br />
rotating coil pole shoes rotating coil<br />
Table 2.4.42: Search coil curvature applied for measuring the main dipoles of the different facilities.<br />
Facility Curvature of the search coil [m]<br />
<strong>Super</strong> FRS 12.5, 4.35<br />
CR 8.125<br />
NESR / RESR 8.125<br />
HEBT 62.5, 4.35<br />
Table 2.4.43: Radius of the rotating coil for the different machines for measuring quadrupoles and higher<br />
order correctors (to be adjustment after the magnet designs are fixed).<br />
Facility Radius of the rotating coil [mm]<br />
<strong>Super</strong> FRS 180 (multiplet system)<br />
CR 70, 156<br />
NESR / RESR 90, 128<br />
HEBT 52,5, 65, 156<br />