The cold connection will be manufatured by winding several cables like a cord. Housed in a<br />

flexible transfer line to facilitate the laying of cold connection within the buildings.<br />

Figure 2.4.156: Flexible Transfer line housing bus bars [107].<br />

The winding process is possible either with 7 cables or 19 cables. As an even number of cables is<br />

required for the electrical connection one of the cables will be replaced by a tube with equal outer<br />

diameter. The geometric data for both solutions are given in the following table:<br />

Table 2.4.39: Geometric data of the cold electrical connection.<br />

Number of electrical circuits 3 9<br />

Number of cable 6 18<br />

Number of tubes for returning gas 1 1<br />

Outer diameter [m] 0.143 0.163<br />

Bending radius<br />

3 bends [m] 1.8 1.9<br />

The flexible connection will be supplied on a standard cable drum (4.2m diameter). The termination<br />

of the connection will look like given in Figure 2.4.157.<br />