instance quenches or the transport from measuring place into the tunnel can produce changes in<br />

position of yoke compared to the cryostat.<br />

Due to the fact that the cryostat will need to provide stable supports for the fiducials, it was already<br />

recommended to attach great importance to the stability of the cryostat itself.<br />

Fiducialization of superconducting magnets is a challenge, that needs careful preparatory work –<br />

some points are mentioned above –, which goes far beyond a single measurement to relate some<br />

points to each other.<br />

2.4.A3.2.2 Considerations on total error budget<br />

Undoubtedly the process of fiducialization has to be at least as accurate as the positioning of the<br />

component to their nominal coordinates; actually much more accurate than that, due to the different<br />

sources of errors, which form the total error of a final magnet position within the tunnel [97].<br />

Possible sources of error:<br />

► Manufacturing<br />

► Determination of the axis / "magnetic measurements"<br />

► Relating axis to fiducials / "geometric measurements"<br />

► Deformation of cryostat / deformation of correlated fiducials<br />

► Displacement magnet versus cryostat due to transport<br />

► Residuals after least square network adjustment<br />

► Uncertainty of measurements during alignment procedure<br />

► Movement of the floor (long / short term)<br />

► etc.<br />

⇒ Total error of final magnet position within the tunnel, which can be expressed as<br />

s² = si² + sj² + sk² + sl² + ...<br />

This quadratic sum of all individual errors has to be taken into account when reflecting on positional<br />

tolerances, which are usually several times the r.m.s. again. Note that assumed errors of 0.1<br />

(0.15 / 0.2 / ...) mm for all above mentioned error sources (which does not reflect the truth in either<br />

case) yield to a total error of 0.3 (0.4 / 0.6 / ...) mm.<br />

The knowledge of a total error budget can help to derivate or re-evaluate reasonable tolerances.<br />

2.4.A3.2.3 Tolerances<br />

A high degree of accuracy is required in the spatial positioning of accelerator components. Up to<br />

now for FAIR alignment tolerances are not finalized; thus accuracy of reference points, which will<br />

be needed in the entire ring tunnel etc. to create a survey network, is not defined yet.<br />

However, tolerances can be assumed to be in a range of some hundred microns, similar to the<br />

existing machine(s). This assumption leads to the choice of the measuring technology, whose<br />

accuracy of measurement has to be at least three to five times better than the given tolerance.<br />