02.02.2013 Views

A750 (ST and XT) for SIMATIC PCS7 with - WinMOD

A750 (ST and XT) for SIMATIC PCS7 with - WinMOD

A750 (ST and XT) for SIMATIC PCS7 with - WinMOD

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Ò<br />

Software Testing <strong>and</strong> Process Simulation <strong>with</strong> <strong>WinMOD</strong><br />

<strong>WinMOD</strong> Ò<br />

Software <strong>for</strong> Automation Technology<br />

·<br />

·<br />

·<br />

·<br />

Planning, Development, Testing<br />

Validation <strong>and</strong> Pre-inspection<br />

Training <strong>and</strong> Presentation<br />

Consulting <strong>and</strong> Changing<br />

Test Workstation <strong>with</strong> Virtual Automation System<br />

<strong>ST</strong>EP7 / <strong>PCS7</strong><br />

PLCSIM (1)<br />

I/PI/<br />

M/DB<br />

Order No. Item<br />

W<strong>A750</strong>A<strong>ST</strong>70<br />

W<strong>A750</strong>A<strong>XT</strong>70<br />

Q/PQ/<br />

M/DB<br />

<strong>WinMOD</strong><br />

<strong>A750</strong> (1)<br />

All on a single workstation !<br />

PLCSIM (7) PLCSIM (8)<br />

I/PI/<br />

M/DB<br />

COM interface<br />

HMI<br />

WinCC<br />

ProTool<br />

Q/PQ/<br />

M/DB<br />

I/PI/<br />

M/DB<br />

<strong>WinMOD</strong> process<br />

periphery / plant simulation<br />

<strong>WinMOD</strong> Configuration <strong>A750</strong> <strong>ST</strong><br />

Configuration <strong>and</strong> driver software <strong>A750</strong> <strong>ST</strong> incl. manual<br />

(single-driver license)<br />

<strong>WinMOD</strong> Configuration <strong>A750</strong> <strong>XT</strong><br />

Configuration <strong>and</strong> driver software <strong>A750</strong> <strong>XT</strong> incl. manual<br />

(multi-driver license)<br />

Datasheet <strong>WinMOD</strong> Configuration <strong>A750</strong> - 09/2011<br />

Mewes & Partner<br />

<strong>WinMOD</strong> Configuration <strong>A750</strong><br />

Ò<br />

<strong>for</strong> <strong>SIMATIC</strong> PCS 7<br />

using S7 Simulation S7-PLCSIM<br />

Mewes & Partner GmbH · Neuendorfstr. 15 · D-16761 Hennigsdorf · Tel. :+49 (0)3302 / 2097-0 · Fax:<br />

-111 · http://www.winmod.de<br />

Q/PQ/<br />

M/DB<br />

<strong>WinMOD</strong> <strong>WinMOD</strong><br />

<strong>A750</strong> (7) <strong>A750</strong> (8)<br />

CPU<br />

<strong>WinMOD</strong><br />

HMI<br />

<strong>ST</strong>EP 7<br />

PLCSIM


<strong>WinMOD</strong> Configuration <strong>A750</strong> - Specification<br />

Use Cases<br />

Configuration <strong>A750</strong> is recommended <strong>for</strong>:<br />

�<br />

�<br />

�<br />

�<br />

Signal Transfer<br />

�<br />

�<br />

�<br />

<strong>WinMOD</strong> Configuration Software <strong>A750</strong><br />

<strong>A750</strong> import features:<br />

� I/Q <strong>and</strong> PI/PQ signal ranges are automatically configured by importing the S7<br />

hardware configuration (CFG file). In addition, all signal ranges including those<br />

of data blocks <strong>and</strong> flag memories can be configured manually.<br />

� The signal list of the automation system can be directly imported.<br />

Configuration variant <strong>A750</strong> <strong>ST</strong> (St<strong>and</strong>ard):<br />

�<br />

�<br />

Configuration variant <strong>A750</strong> <strong>XT</strong> (Extended):<br />

�<br />

�<br />

�<br />

System Requirements<br />

�<br />

�<br />

�<br />

�<br />

System interconnection of <strong>WinMOD</strong> <strong>and</strong> S7-PLCSIM, the S7 simulation by SIEMENS.<br />

Realization of partly or completely virtual automation plants including real-time<br />

process simulation.<br />

Software testing of AS programs (HMI, <strong>ST</strong>EP 7/ PCS 7).<br />

Implementation of a cost-efficent testing environment <strong>with</strong>out real AS hardware, e.g. <strong>for</strong><br />

simulation of devices <strong>and</strong> plants to train operating <strong>and</strong> maintenance personnel.<br />

Signal transfer between <strong>WinMOD</strong> <strong>and</strong> S7-PLCSIM on the same machine is accomplished<br />

using a specific COM interface.<br />

There are no modifications needed in regard to the <strong>ST</strong>EP 7 program.<br />

From <strong>WinMOD</strong> version 5.1 read <strong>and</strong> write access is provided <strong>for</strong>:<br />

- S7 I/O image memory (I/Q),<br />

- I/O peripheral image (PI/PQ),<br />

- flag memory (M), <strong>and</strong><br />

- data blocks (DB).<br />

<strong>WinMOD</strong> System Software <strong>ST</strong>.<br />

Operating <strong>with</strong> one S7-PLCSIM instance (one virtual PLC).<br />

<strong>WinMOD</strong> System Software <strong>XT</strong> required.<br />

Parallel operation using up to 8 S7-PLCSIM instances (max. 8 virtual PLCs).<br />

Automatic start option <strong>for</strong> S7-PLCSIM projects (PLC file).<br />

actual <strong>WinMOD</strong> System Software (more in<strong>for</strong>mation about System Software<br />

under www.winmod.de)<br />

<strong>WinMOD</strong> <strong>and</strong> S7-PLCSIM, both installed on the same PC.<br />

PLCSIM version 5.4 SP 3/ SP 4 (later Service Packs after approval by Mewes & Partner).<br />

Optional the <strong>SIMATIC</strong> Software environment <strong>for</strong> HMI <strong>and</strong> S7 programming.<br />

Please note also the S7-PLCSIM user manual.<br />

Subject to technical changes.<br />

Mewes & Partner GmbH<br />

Neuendorfstr. 15 · D-16761 Hennigsdorf<br />

e-mail: <strong>WinMOD</strong>@Mewes-Partner.de<br />

http://www.winmod.de<br />

Tel.: +49 (0)3302 / 2097-0<br />

Fax: +49 (0)3302 / 2097-111<br />

<strong>WinMOD</strong>_Config_<strong>A750</strong>_en.cdr © 2011 Mewes & Partner GmbH� All rights reserved. �All<br />

used product names <strong>and</strong> trade marks remain property of their respective owners.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!