catalogue intelligent relays - Hiquel

catalogue intelligent relays - Hiquel catalogue intelligent relays - Hiquel

01.02.2013 Views

Surge Guard 4:09 ETHERNET DIN Surge Guard X01.00 mechanical dimensions: 85mm 72mm electrical wiring diagram: IDC/MOD-PLUG 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 Terminal Shield Shield Terminal + - 1M + - Surge Guard IDC/MOD-PLUG HIGH QUALITY ELECTRONICS overview symmetrical and asymmetrical voltage protection DIN rail mounting for cable (IDC-Connector 110+Krone type) and modular-jack-wiring as a interface between single wiring to modular-jack-wiring more options for a PoE wiring specification Line to line voltages 1:2, 3:6, 4:5, 7:8 Stand off voltage - 6,8V @ 1mA max. current 100A @ tp= 8/20µs max. power 200W @ tp= 8/20µs Line to earth (GND) volt. (1+2) : GND (3+6) : GND (4+5) : GND (7+8) : GND Stand off voltage Break down voltage Impulse break down volt. Shield : GND 70 Vdc 110 Vdc < 450V @ 100V/µs Impulse < 500V @ 1000V/µs Impulse Please note: After a disturbance the module have to be reviewed or appropriate exchanged. The full effect can only be guaranteed with a properly connected PE conductor. ordering information part no housing types special HIQUEL 2009

World of Automation Chapter 5: Human Machine Interfaces www.hiquel.com

Surge Guard<br />

4:09<br />

ETHERNET<br />

DIN<br />

Surge Guard<br />

X01.00<br />

mechanical dimensions:<br />

85mm<br />

72mm<br />

electrical wiring diagram:<br />

IDC/MOD-PLUG<br />

1 1<br />

2 2<br />

3 3<br />

4 4<br />

5 5<br />

6 6<br />

7 7<br />

8 8<br />

Terminal Shield Shield<br />

Terminal<br />

+ -<br />

1M<br />

+ -<br />

Surge Guard<br />

IDC/MOD-PLUG<br />

HIGH QUALITY ELECTRONICS<br />

overview<br />

symmetrical and asymmetrical voltage<br />

protection<br />

DIN rail mounting<br />

for cable (IDC-Connector 110+Krone type)<br />

and modular-jack-wiring<br />

as a interface between single wiring<br />

to modular-jack-wiring<br />

more options for a PoE wiring<br />

specification<br />

Line to line voltages 1:2, 3:6, 4:5, 7:8<br />

Stand off voltage<br />

- 6,8V @ 1mA<br />

max. current<br />

100A @ tp= 8/20µs<br />

max. power 200W @ tp= 8/20µs<br />

Line to earth (GND) volt. (1+2) : GND<br />

(3+6) : GND<br />

(4+5) : GND<br />

(7+8) : GND<br />

Stand off voltage<br />

Break down voltage<br />

Impulse break down volt.<br />

Shield : GND<br />

70 Vdc<br />

110 Vdc<br />

< 450V @ 100V/µs Impulse<br />

< 500V @ 1000V/µs Impulse<br />

Please note:<br />

After a disturbance the<br />

module have<br />

to be reviewed or appropriate exchanged.<br />

The full effect can only be guaranteed<br />

with a properly connected PE conductor.<br />

ordering information<br />

part no housing types<br />

special<br />

HIQUEL 2009

Hooray! Your file is uploaded and ready to be published.