SLS-Universal interface converter 3:23 RS232 RS485 RS232 RS485 DIN X01.00 SLS-500-Modbus Configuration: SLS-500-Configurator is available for programming and configuration: : - M- L+ B2 Rx2 RS232 SLS Tx2 A2 + Do not connect a module to A1 and B1 during SLS-Modbus- Converter configuration Modbus is a protocol based on Master/Slave architecture which has been developed for industrial control networking. Due to the trouble-free exchange of data between Modbus and a wide range of serial interfaces, this system has widespread consumer acceptance. Boot M- * measurement input galvanically isolated from the power supply Config/RS232 Rx1 B1 Tx1 Modbus A1 Modbus HIGH QUALITY ELECTRONICS overview Modbus converter expansion module supply voltage 24V= RS232 / modbus converter the following baud rates are available: 9600, 19200, 38400 you can choose a modbus address from ID 0x0000 - ID 0x7F SLS-500-Configurator configuration cable and SLS-500 cable are delivered with the modbus converter LED indicators for receiving (Rx) and transmission (Tx) 45mm DIN rail mount housing specification supply voltage 24V= ±10% power consumption 1W nominal settings used addresses protection class screws screw tightening torque weight dimensions 9600 baud modbus SLS-500-memory type 0x0000 to bit-variables 0x7F 0x0000 to analogous-variables } 0x7F terminals IP20 housing IP50 pozidrive 1 0,6..0,8 Nm 120g } 45 x 85 x 75mm operating conditions -15 to +55 °C non condensing ordering information part no supply input inp. galv. iso.* Gehäusetypen output outp. galv. iso.* housing types SLS-500-Modbus-Conv. 24V= - - - - C HIQUEL 2009
Accessories wind sensor cable sensor ordering information outdoor sensor rain sensor surface-contacting sensor weather station part no supply output measuring range rain sensor RM1 24Vdc/Vac relay NO/NC 30V/4A wind sensor WS1 24Vdc 0...10Vdc 0,7...40m/s temperature sensor passive cable surface -contacting sensor cable surface-contacting sensor surface-contacting sensor outdoor temperature sensor cable temperature sensor cable temperature sensor part no with silicon cable output measuring range ALTF1-PT1000 no PT1000 -10...+105°C ALTF1-PT1000-S yes PT1000 -30...+180°C ALTF2-PT1000 no PT1000 -30...+110°C ATF1-PT1000 no PT1000 -50...+90°C HTF-PT1000 no PT1000 -10...+105°C HTF-PT1000-S yes PT1000 -50...+180°C temperature sensor active part no voltage output 0..10Vdc sensor measuring range surface-contacting sensor ALTM2-U PT1000 -50..+50°C outdoor temperature sensor ATM1-U PT1000 5 ranges adjustable -50..150°C temperature sensor active part no current output 4..20mA sensor measuring range surface-contacting sensor ALTM2-I PT1000 -50..+50°C outdoor temperature sensor ATM1-I PT1000 5 ranges adjustable -50..150°C light intensity sensor part no voltage ouput 0..10Vc sensor measuring range Brightness sensor AHKF-0,5-U 0...500Lux outdoor light intensity sensor AHKF-60-U 0...60000 Lux Light intensity sensor part no current output 4..20mA sensor measuring range Brightness sensor AHKF-0,5-I 0...500Lux outdoor light intensity sensor AHKF-60-I 0...60000 Lux * At request are also other sensor types and measuring ranges available HIQUEL 2009 X01.00 HIGH QUALITY ELECTRONICS 3:24 Accessories
- Page 1 and 2: World of Automation Chapter 1: Gene
- Page 3 and 4: 2 2 DIN 11 RTC IP50 C PT100 PTC RS2
- Page 5 and 6: World of Automation Chapter 2: SLS-
- Page 7 and 8: Structured control Basically there
- Page 9 and 10: Area of use: SLS-500 Series Complet
- Page 11 and 12: Automation Process technology Machi
- Page 13 and 14: Remote overview RADIO report contro
- Page 15 and 16: SLS-500 modules overview HIQUEL 200
- Page 17 and 18: compact control SLS-510 , SLS-520 2
- Page 19 and 20: SLS-500-CAN overview system base mo
- Page 21 and 22: SLS-500-SiConfig overview Communica
- Page 23 and 24: SLS-8207 power supply 2A SLS-8207 p
- Page 25 and 26: 3 Chapter .01 .02 .03 .04 .05 .06 .
- Page 27 and 28: SLS-500-D..-16A digital I/O module
- Page 29 and 30: 3:04 in 4 3 out DIN RS485 9* 9= 81
- Page 31 and 32: SLS-500-8D digital output module 3:
- Page 33 and 34: FBR-remote room control unit part n
- Page 35 and 36: SLS-500-PT100 temperature input mod
- Page 37 and 38: SLS-500-AU analogue I/O module (vol
- Page 39 and 40: SLS-500-AU-AU analogue I/O module (
- Page 41 and 42: SLS-500-AI-AU analogue I/O module 3
- Page 43 and 44: SLS-500-SIO serial I/O interface mo
- Page 45 and 46: SLS-500-GW Gateway 3:20 DIN RS485 R
- Page 47: SLS-500-MBUS overview MBUS-MODBUS-p
- Page 51 and 52: 4 Chapter .01 .02 .03 .04 .05 .06 .
- Page 53 and 54: USBport 12xx overview 2-port RS-232
- Page 55 and 56: COMport Rep. overview Industrial RS
- Page 57 and 58: EDS-316/308/305 overview The EDS-31
- Page 59 and 60: Nport 52xx overview 2-port RS-232/4
- Page 61 and 62: World of Automation Chapter 5: Huma
- Page 63 and 64: WEB-Studio is a powerful, integrate
- Page 65 and 66: HISTAR The HISTAR design convinces
- Page 67 and 68: HISTAR-Audio HISTAR The Multimedia-
- Page 69 and 70: HTPC-670S- Compact Panel PC 5:07 X0
- Page 71 and 72: HTPC-870E Ultracompact embedded Pan
- Page 73 and 74: Histar-870E embedded PC for wall mo
- Page 75 and 76: HPC-850E Compact embedded box PC 5:
- Page 77 and 78: Histar-200 Compact wall mount monit
- Page 79 and 80: World of Automation Chapter 6: Alar
- Page 81 and 82: SMS-Master Monitor and Control via
- Page 83 and 84: SMS-Master modules supply voltage p
- Page 85 and 86: 7 Chapter .01 .02 .03 .04 .05 .06 .
- Page 87 and 88: Programming SoftWIRE and SoftwirePL
- Page 89 and 90: Compact module HI-86 minimodule Pro
- Page 91 and 92: SLS-86 system base module supply vo
- Page 93 and 94: SLS-D..-16A overview digital I/O ex
- Page 95 and 96: SLS-8D overview digital output expa
- Page 97 and 98: SLS-PTC overview PTC (thermistor) i
SLS-Universal interface converter<br />
3:23<br />
RS232<br />
RS485<br />
RS232<br />
RS485<br />
DIN<br />
X01.00<br />
SLS-500-Modbus<br />
Configuration:<br />
SLS-500-Configurator is available<br />
for programming and configuration:<br />
:<br />
-<br />
M-<br />
L+<br />
B2 Rx2<br />
RS232<br />
SLS<br />
Tx2<br />
A2<br />
+<br />
Do not connect a<br />
module to A1 and B1<br />
during SLS-Modbus-<br />
Converter configuration<br />
Modbus is a protocol based on Master/Slave<br />
architecture which has been developed for<br />
industrial control networking.<br />
Due to the trouble-free exchange of data<br />
between Modbus and a wide range of serial<br />
interfaces, this system has widespread<br />
consumer acceptance.<br />
Boot<br />
M-<br />
* measurement input galvanically isolated from the power supply<br />
Config/RS232<br />
Rx1<br />
B1<br />
Tx1<br />
Modbus<br />
A1<br />
Modbus<br />
HIGH QUALITY ELECTRONICS<br />
overview<br />
Modbus converter expansion module<br />
supply voltage 24V=<br />
RS232 / modbus converter<br />
the following baud rates are available:<br />
9600, 19200, 38400<br />
you can choose a modbus address from<br />
ID 0x0000 - ID 0x7F<br />
SLS-500-Configurator<br />
configuration cable and SLS-500 cable are<br />
delivered with the modbus converter<br />
LED indicators for receiving (Rx)<br />
and transmission (Tx)<br />
45mm DIN rail mount housing<br />
specification<br />
supply voltage<br />
24V= ±10%<br />
power consumption 1W nominal<br />
settings<br />
used addresses<br />
protection class<br />
screws<br />
screw tightening torque<br />
weight<br />
dimensions<br />
9600 baud<br />
modbus SLS-500-memory type<br />
0x0000<br />
to<br />
bit-variables<br />
0x7F<br />
0x0000<br />
to analogous-variables }<br />
0x7F<br />
terminals IP20<br />
housing IP50<br />
pozidrive 1<br />
0,6..0,8 Nm<br />
120g<br />
}<br />
45 x 85 x 75mm<br />
operating conditions -15 to +55 °C non condensing<br />
ordering information<br />
part no supply input inp. galv. iso.* Gehäusetypen<br />
output outp. galv. iso.* housing types<br />
SLS-500-Modbus-Conv. 24V= - - -<br />
- C<br />
HIQUEL 2009