catalogue intelligent relays - Hiquel
catalogue intelligent relays - Hiquel catalogue intelligent relays - Hiquel
SLS-500-AI supply voltage 24V= overview analogue I/O expansion module 4 analogue inputs 0-20 mA 1 analogue output 0-10 V 4 transistor outputs (PNP) LED indicators for outputs RS485 interface 1 potentiometer pre-programmable timer functions 45mm DIN rail mount housing supply voltage power consumption output transistor spec. analogue output spec. resolution repeat accuracy precision analogue input spec. resolution input resistance protection class specification 24V= ±10% 0,5W nominal max. 800mA 24V= PNP max. 8kHz 0 - 10V= max. 2mA 12 bit 0,1% ±0,5% 0 - 20mA 10 bit 250 Ohm terminals IP20 housing IP50 screws pozidrive 1 screw tightening torque 0,6..0,8 Nm weight 120g dimensions 45 x 85 x 75mm operating conditions -15 to +55°C non condensing ordering information part no type supply input inp. galv. iso.* output outp. galv. iso.* housing types SLS-500-AI-C local 24V= 4x 0-20mA no 4x trans. PNP SLS-500-AI-D remote 24V= 4x 0-20mA no 4x trans. PNP * The ordering information for various sensors you will find on page 03:23 * measurement input galvanically isolated from power supply HIQUEL 2009 X01.00 BUS HIGH QUALITY ELECTRONICS local remote ROM + - RS485 0- 20mA + - M- L+ AI1 DO1 T L AI2 DO2 T L no no AI3 DO3 T L AI4 T DO4 L 0- 10V AO1 C1-4 C C 4 in 4 out I 4-20mA DIN RS485 SLS-500-AI analogue I/O module (current) 3:13
SLS-500-AU-AU analogue I/O module (voltage) 3:14 4 in 4 out U 0-10V DIN RS485 X01.00 BUS SLS-500-AU-AU local remote - ROM RS485 + M- L+ HIGH QUALITY ELECTRONICS overview analogue I/O expansion module supply voltage 24V= 4 analogue inputs 0-10V 4 analogue outputs 0-10V RS485 interface 1 potentiometer pre-programmable timer functions 45mm DIN rail mount housing specification supply voltage power consumption analogue output spec. resolution repeat accuracy precision analogue input spec. resolution input resistance protection class 0,5W nominal 0 - 10V= max. 2mA 12 bit 0,1% ±0,5% 0 - 10V= 10 bit 50kOhm terminals housing IP20 IP50 screws pozidrive 1 screw tightening torque 0,6..0,8 Nm weight 120g dimensions 45 x 85 x 75mm operating conditions -15 to +55°C non condensing ordering information part no type supply input inp. galv. iso.* Gehäusetypen output outp. galv. iso.* housing types SLS-500-AU-AU-C local 24V= 4x 0-10V no 4x 0-10V no C SLS-500-AU-AU-D remote 24V= 4x 0-10V no 4x 0-10V no C * The ordering information for various sensors you will find on page 03:23 * measurement input galvanically isolated from the power supply AI1 AO1 AI2 V A V A V A V A AI3 V A V A V A AO2 AO3 AI4 AO4 Ai V A T Ao T 24V= ±10% HIQUEL 2009
- Page 1 and 2: World of Automation Chapter 1: Gene
- Page 3 and 4: 2 2 DIN 11 RTC IP50 C PT100 PTC RS2
- Page 5 and 6: World of Automation Chapter 2: SLS-
- Page 7 and 8: Structured control Basically there
- Page 9 and 10: Area of use: SLS-500 Series Complet
- Page 11 and 12: Automation Process technology Machi
- Page 13 and 14: Remote overview RADIO report contro
- Page 15 and 16: SLS-500 modules overview HIQUEL 200
- Page 17 and 18: compact control SLS-510 , SLS-520 2
- Page 19 and 20: SLS-500-CAN overview system base mo
- Page 21 and 22: SLS-500-SiConfig overview Communica
- Page 23 and 24: SLS-8207 power supply 2A SLS-8207 p
- Page 25 and 26: 3 Chapter .01 .02 .03 .04 .05 .06 .
- Page 27 and 28: SLS-500-D..-16A digital I/O module
- Page 29 and 30: 3:04 in 4 3 out DIN RS485 9* 9= 81
- Page 31 and 32: SLS-500-8D digital output module 3:
- Page 33 and 34: FBR-remote room control unit part n
- Page 35 and 36: SLS-500-PT100 temperature input mod
- Page 37: SLS-500-AU analogue I/O module (vol
- Page 41 and 42: SLS-500-AI-AU analogue I/O module 3
- Page 43 and 44: SLS-500-SIO serial I/O interface mo
- Page 45 and 46: SLS-500-GW Gateway 3:20 DIN RS485 R
- Page 47 and 48: SLS-500-MBUS overview MBUS-MODBUS-p
- Page 49 and 50: Accessories wind sensor cable senso
- Page 51 and 52: 4 Chapter .01 .02 .03 .04 .05 .06 .
- Page 53 and 54: USBport 12xx overview 2-port RS-232
- Page 55 and 56: COMport Rep. overview Industrial RS
- Page 57 and 58: EDS-316/308/305 overview The EDS-31
- Page 59 and 60: Nport 52xx overview 2-port RS-232/4
- Page 61 and 62: World of Automation Chapter 5: Huma
- Page 63 and 64: WEB-Studio is a powerful, integrate
- Page 65 and 66: HISTAR The HISTAR design convinces
- Page 67 and 68: HISTAR-Audio HISTAR The Multimedia-
- Page 69 and 70: HTPC-670S- Compact Panel PC 5:07 X0
- Page 71 and 72: HTPC-870E Ultracompact embedded Pan
- Page 73 and 74: Histar-870E embedded PC for wall mo
- Page 75 and 76: HPC-850E Compact embedded box PC 5:
- Page 77 and 78: Histar-200 Compact wall mount monit
- Page 79 and 80: World of Automation Chapter 6: Alar
- Page 81 and 82: SMS-Master Monitor and Control via
- Page 83 and 84: SMS-Master modules supply voltage p
- Page 85 and 86: 7 Chapter .01 .02 .03 .04 .05 .06 .
- Page 87 and 88: Programming SoftWIRE and SoftwirePL
SLS-500-AU-AU analogue I/O module (voltage)<br />
3:14<br />
4<br />
in<br />
4 out<br />
U<br />
0-10V<br />
DIN<br />
RS485<br />
X01.00<br />
BUS<br />
SLS-500-AU-AU<br />
local<br />
remote<br />
-<br />
ROM<br />
RS485<br />
+<br />
M-<br />
L+<br />
HIGH QUALITY ELECTRONICS<br />
overview<br />
analogue I/O expansion module<br />
supply voltage 24V=<br />
4 analogue inputs 0-10V<br />
4 analogue outputs 0-10V<br />
RS485 interface<br />
1 potentiometer<br />
pre-programmable timer functions<br />
45mm DIN rail mount housing<br />
specification<br />
supply voltage<br />
power consumption<br />
analogue output spec.<br />
resolution<br />
repeat accuracy<br />
precision<br />
analogue input spec.<br />
resolution<br />
input resistance<br />
protection class<br />
0,5W nominal<br />
0 - 10V= max. 2mA<br />
12 bit<br />
0,1%<br />
±0,5%<br />
0 - 10V=<br />
10 bit<br />
50kOhm<br />
terminals<br />
housing<br />
IP20<br />
IP50<br />
screws<br />
pozidrive 1<br />
screw tightening torque 0,6..0,8 Nm<br />
weight<br />
120g<br />
dimensions<br />
45 x 85 x 75mm<br />
operating conditions -15 to +55°C non condensing<br />
ordering information<br />
part no type supply input inp. galv. iso.* Gehäusetypen<br />
output outp. galv. iso.* housing types<br />
SLS-500-AU-AU-C local<br />
24V= 4x 0-10V<br />
no<br />
4x 0-10V<br />
no<br />
C<br />
SLS-500-AU-AU-D remote 24V= 4x 0-10V<br />
no<br />
4x 0-10V<br />
no<br />
C<br />
* The ordering information for various sensors you will find on page 03:23<br />
* measurement input galvanically isolated from the power supply<br />
AI1<br />
AO1<br />
AI2<br />
V<br />
A<br />
V<br />
A<br />
V<br />
A<br />
V<br />
A<br />
AI3<br />
V A V A V A<br />
AO2<br />
AO3<br />
AI4<br />
AO4<br />
Ai<br />
V A<br />
T<br />
Ao<br />
T<br />
24V= ±10%<br />
HIQUEL 2009