Compressors / compressed air - Aircraft
Compressors / compressed air - Aircraft
Compressors / compressed air - Aircraft
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Compressed <strong>air</strong> processing<br />
Compressed <strong>air</strong> quality classes according to DIn ISo 8573<br />
The <strong>compressed</strong> <strong>air</strong> quality classed<br />
according to DIN ISO 8573-1 facilitate the<br />
definition of his requirements and the<br />
selection of the treatment components<br />
for the user. The standard is based on<br />
the indications of the manufacturer which<br />
have determined admissible limit values<br />
regarding the purity of <strong>compressed</strong> <strong>air</strong> for<br />
their systems and machines.<br />
Class<br />
0<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
Particle size<br />
in µm max.<br />
The standard DIN ISO 8573-1 defines the<br />
quality classes of the <strong>compressed</strong> <strong>air</strong><br />
regarding:<br />
oil content<br />
Determining the remaining quantities of<br />
aerosols and hydrocarbon which may be<br />
contained in the <strong>compressed</strong> <strong>air</strong>.<br />
Particle size and density<br />
Determining the size and concentration of<br />
particulates which may still be contained<br />
Particle (dirt) water (condensate) oil<br />
Particle density<br />
in mg/m³ max.<br />
Pressure dew point<br />
in °C<br />
in the <strong>compressed</strong> <strong>air</strong>.<br />
Pressure dew point<br />
Determining the temperature to which it<br />
is possible to cool down the <strong>compressed</strong><br />
<strong>air</strong> without causing that the water vapour<br />
included in the <strong>compressed</strong> <strong>air</strong> is being<br />
condensed.<br />
The pressure due point changes according<br />
to the <strong>air</strong> pressure.<br />
water content<br />
in g/m³<br />
Remaining oil<br />
content in mg/m³<br />
< 0.1 < 0.1 < -70 °C < 0.003 < 0.01<br />
0.1 0.1 -70 °C 0.003 0.01<br />
1 1 -40 °C 0.11 0.1<br />
5 5 -20 °C 0.88 1<br />
15 15 +3 °C 6 5<br />
40 40 +7 °C 7.8 25<br />
> 40 > 40 +10 °C 9.4 > 25<br />
- - > +10 °C > 9.4 -<br />
102 Built according to CE directives