WHITE BOOK - GypLyner ENCASE - British Gypsum
WHITE BOOK - GypLyner ENCASE - British Gypsum
WHITE BOOK - GypLyner ENCASE - British Gypsum
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
398<br />
<strong>GypLyner</strong> <strong>ENCASE</strong><br />
<strong>GypLyner</strong> framed structural steel encasement system<br />
!<br />
This section includes updated information, added<br />
since it was first published in July 2009. Please see<br />
the <strong>WHITE</strong> <strong>BOOK</strong> update document for details.<br />
Last updated 25/05/2012<br />
Cadbury offices,<br />
Bournville, Birmingham
<strong>GypLyner</strong> <strong>ENCASE</strong><br />
<strong>GypLyner</strong> <strong>ENCASE</strong> is a steel encasement system which provides a<br />
rapid method of cladding structural steel sections to provide up<br />
to 180 minutes fire resistance. The system will protect all<br />
universal column and beam sections with flange thicknesses<br />
between 6mm and 28mm. As described in the <strong>British</strong> <strong>Gypsum</strong><br />
FIRE <strong>BOOK</strong>, <strong>GypLyner</strong> <strong>ENCASE</strong> will also protect many joist sections,<br />
portal frames, and castellated beam sections. It can be used in<br />
any type of building where encasement to structural steel is<br />
required.<br />
Applications<br />
For the encasement of structural steel.<br />
Sector<br />
3<br />
3<br />
3<br />
Office / commercial<br />
Education<br />
Custodial<br />
B<br />
A B<br />
Gypframe<br />
GL1 Lining<br />
Channel<br />
A<br />
3<br />
3<br />
3<br />
Gypframe GL10<br />
<strong>GypLyner</strong> Steel<br />
Framing Clip<br />
Retail<br />
Healthcare<br />
High-rise multi-occupancy<br />
3<br />
3<br />
3<br />
Key facts<br />
l Quick and simple to<br />
install<br />
l Lightweight support<br />
framework constructed<br />
from <strong>GypLyner</strong><br />
components<br />
l Easy to box-out<br />
l Up to 180 minutes fire<br />
protection to structural<br />
steel<br />
Sport and leisure<br />
Industrial<br />
Auditoria<br />
30 180<br />
mins<br />
GypWall RAPID and <strong>GypLyner</strong> RAPID dB<strong>ENCASE</strong> Plus<br />
399<br />
93
<strong>GypLyner</strong> <strong>ENCASE</strong><br />
9<br />
400<br />
System components<br />
Gypframe metal products<br />
Board products<br />
GL1 Lining Channel Length<br />
GL3 Channel Connector<br />
GL10 <strong>GypLyner</strong> Steel<br />
Framing Clips<br />
GA2 Steel Angle Length<br />
Gyproc FireLine 1<br />
2400, 2700mm<br />
3000, 3600mm<br />
3200mm<br />
GFS1 Fixing Strap Length<br />
or<br />
Thickness 12.5, 15mm<br />
Width 900, 1200mm<br />
Gyproc DuraLine 1<br />
Thickness 15mm<br />
Width 1200mm<br />
Glasroc F FIRECASE<br />
Thickness 15, 20, 25, 30mm<br />
Width 600, 1200mm<br />
Glasroc F MULTIBOARD<br />
2400mm<br />
GFT1 Fixing ‘T’ Length<br />
2400mm<br />
Thickness 6, 10, 12.5mm<br />
Width 1200mm<br />
1 Moisture resistant boards are specified in intermittent wet use areas,<br />
e.g. shower cubicles.<br />
SPECSURE<br />
L I F E T I M E S Y S T E M W A R R A N T Y<br />
Fixing and finishing products<br />
Gyproc Wafer Head Drywall Screws<br />
For Gypframe metal-to-metal fixing less than<br />
0.8mm thick (‘I’ studs less than 0.6mm thick).<br />
Gyproc Drywall Screws<br />
For fixing boards to Gypframe metal framing less<br />
than 0.8mm thick (‘I’ studs less than 0.6mm thick).<br />
Glasroc F FIRECASE Screws<br />
For board-to-board fixing of Glasroc F FIRECASE, and<br />
for board-to-metal fixing of Glasroc F FIRECASE and<br />
Glasroc F MULTIBOARD.<br />
Gyproc jointing materials<br />
For seamless jointing.<br />
www.british-gypsum.com<br />
Thistle Multi-Finish or Thistle Board Finish<br />
To provide a plaster skim finish.<br />
Always use genuine branded <strong>British</strong> <strong>Gypsum</strong> components to qualify for SpecSure ® lifetime warranty<br />
or<br />
Thistle Durafinish<br />
To provide improved resistance to accidental damage.<br />
or<br />
Thistle Spray Finish<br />
<strong>Gypsum</strong> finish plaster for spray or hand application.
T 0844 800 1991 F 0844 561 8816 E bgtechnical.enquiries@bpb.com<br />
Installation overview<br />
Four-sided protection to steel columns<br />
Gypframe GL10 <strong>GypLyner</strong> Steel Framing Clips are friction-fitted at<br />
maximum 800mm centres onto the column flanges. Gypframe GL1<br />
Lining Channel is located over the clips to form the steel framework.<br />
Where lengths of Gypframe GL1 Lining Channel abut, GL10 clips are<br />
located either side to provide support. Alternatively use Gypframe<br />
GL3 Channel Connector to join the ends of Gypframe GL1 Lining<br />
Channels together. Boards are cut to width and fixed to all framing<br />
members using Gyproc Drywall Screws. Board joints on adjacent<br />
sides are staggered by a minimum 600mm. Short lengths of<br />
Gypframe GL1 Lining Channel, Gypframe GFS1 Fixing Strap, or<br />
Gypframe GFT1 Fixing ‘T’ are cut to form horizontal noggings to back<br />
board-end joints.<br />
Three-sided protection to steel columns and beams<br />
Gypframe GA2 Steel Angle is located to both sides of the wall / soffit<br />
flange and secured using appropriate fixings at 600mm centres.<br />
GL10 clips are friction-fitted at maximum 800mm centres to both<br />
edges of the bottom flange ensuring that adjacent clips are in<br />
alignment. Gypframe GL1 Lining Channel is located over the clips to<br />
form the steel framework. Where lengths of Gypframe GL1 Lining<br />
Channel abut, GL10 clips are located to either side to provide<br />
support. Alternatively use Gypframe GL3 Channel Connector to join<br />
the ends of Gypframe GL1 Lining Channels together.<br />
Boards are cut to width and fixed to all framing members using<br />
Gyproc Drywall Screws. Board joints on adjacent sides are staggered<br />
by a minimum 600mm. Noggings are installed to support board<br />
joints. Gyproc FireLine or Glasroc F MULTIBOARD boards are then<br />
screw-fixed to the framing using Gyproc fixings.<br />
Noggings of Gypframe GL1 Lining Channel are installed at 600mm<br />
centres between adjacent Gypframe GL1 Lining Channels to form<br />
supplementary framing.<br />
Boxing out<br />
If the encasement system is required to be enlarged, a ‘boxing out’<br />
method using Gypframe studs and channels can be adopted. See<br />
Construction details – 7 - 8.<br />
Additional fire protection (columns only)<br />
Where 180 minutes fire protection is required, Glasroc F FIRECASE is<br />
specified as the cladding. Glasroc F FIRECASE is fixed through to the<br />
metal framing.<br />
For full installation details, refer to the <strong>British</strong> <strong>Gypsum</strong><br />
SITE <strong>BOOK</strong>, available to download from www.british-gypsum.com<br />
For full installation details, refer to the <strong>British</strong> <strong>Gypsum</strong> SITE <strong>BOOK</strong>, available to download from www.british-gypsum.com<br />
<strong>GypLyner</strong> <strong>ENCASE</strong><br />
401<br />
9
<strong>GypLyner</strong> <strong>ENCASE</strong><br />
9<br />
402<br />
Design<br />
Planning - key factors<br />
<strong>GypLyner</strong> <strong>ENCASE</strong> steel encasement is suitable for protecting<br />
structural steel sections with a section factor A/V (Hp/A) up to<br />
260m-1 , calculated on the basis of box protection to three or four<br />
sides as required. It will protect all universal column and beam<br />
sections described in BS 4: Part 1, and many joist and castellated<br />
beam sections.<br />
Lining selection<br />
The designer should follow the procedure below to determine the<br />
thickness of cladding required:<br />
1. Ascertain whether protection is required on three or four sides of<br />
the section.<br />
2. Find out what period of fire resistance is required.<br />
3. Refer to the A/V (Hp/A) Tables 2 - 4. Locate the steel section to be<br />
protected, listed by its size and mass per metre, and read off the<br />
section factor A/V.<br />
4. Refer to Tables 5 - 8. Locate the A/V value on the vertical scale on<br />
the appropriate table. Read across the chart to the column relating<br />
to the period of fire resistance required and read off the designated<br />
thickness of the relevant cladding required to form the<br />
encasement.<br />
5. Select the type of board to be used.<br />
For castellated sections and cellular beams please refer to the<br />
Association for Specialist Fire Protection publication, ASFP Yellow<br />
Book - ‘Fire Protection for Structural Steel in buildings’ for guidance,<br />
available to download from www.asfp.org.uk<br />
For improved durability and impact resistance, the outer layer of<br />
Gyproc FireLine can be replaced with a layer of 15mm Gyproc<br />
DuraLine.<br />
Size of encasement<br />
The minimum dimension of encasement required for three or<br />
four-sided protection can be determined as shown in Table 1<br />
below. These dimensions can be increased if the encasement needs<br />
to be boxed-out to achieve a specific common dimension, or to<br />
build out beyond fixing bolts, etc. See Construction details – 7 - 8.<br />
Table 1 – The minimum dimension of encasements required for<br />
three or four sided protection<br />
Depth Size<br />
Three-sided Overall steel section depth + 25mm +<br />
the thickness of lining board<br />
Four-sided Overall steel section depth + 50mm +<br />
twice the thickness of lining board<br />
Width Size<br />
Three and Overall steel section width + 20mm +<br />
four-sided the thickness of lining board<br />
Please refer to section 3 - Basic principles of system design for general guidance<br />
www.british-gypsum.com<br />
Partition fixing<br />
Partitions and wall linings can be fixed through to the metal<br />
framework. See Construction details – 5 - 6.<br />
Additional support<br />
Where the steel section web or flange dimension exceeds 600mm,<br />
additional support will be required for the cladding. Noggings of<br />
Gypframe GL1 Lining Channel are installed at 600mm centres<br />
between adjacent Gypframe GL1 Lining Channels to form<br />
supplementary framing.<br />
Water vapour resistance<br />
Vapour control can be provided to encasements which form part of<br />
an external wall lining by using Gyproc FireLine DUPLEX as the lining.<br />
The water vapour resistance can be further improved by treating<br />
the lining surface with two coats of Gyproc Drywall Sealer. Where<br />
Glasroc F FIRECASE or Glasroc F MULTIBOARD forms the lining, vapour<br />
control can be achieved by using a suitable proprietary paint<br />
treatment.<br />
Board finishing<br />
Refer to section 13 – Finishing systems and decorative effects.
T 0844 800 1991 F 0844 561 8816 E bgtechnical.enquiries@bpb.com<br />
Table 2 – Section factor A/V (Hp/A) of Universal Beams Table 3 – Section factor A/V (Hp/A) of Universal Columns<br />
Serial size Mass / metre 3 sides 4 sides<br />
mm kg m -1 m -1<br />
914 x 419 388 45 55<br />
343 50 60<br />
914 x 305 289 60 65<br />
253 65 75<br />
224 75 85<br />
201 80 95<br />
838 x 292 226 70 80<br />
194 80 90<br />
176 90 100<br />
762 x 267 197 70 85<br />
173 80 95<br />
147 95 110<br />
686 x 254 170 75 90<br />
152 85 95<br />
140 90 105<br />
125 100 115<br />
610 x 305 238 50 60<br />
179 70 80<br />
149 80 95<br />
610 x 229 140 80 95<br />
125 90 105<br />
113 100 115<br />
101 110 130<br />
533 x 210 122 85 95<br />
109 95 110<br />
101 100 115<br />
92 110 125<br />
82 120 140<br />
457 x 191 98 90 105<br />
89 100 115<br />
82 105 125<br />
74 115 135<br />
67 130 150<br />
457 x 152 82 105 120<br />
74 115 130<br />
67 125 145<br />
60 140 160<br />
52 160 180<br />
406 x 178 74 105 125<br />
67 115 140<br />
60 130 155<br />
54 145 170<br />
406 x 140 46 160 185<br />
39 190 220<br />
356 x 171 67 105 125<br />
57 125 145<br />
51 135 165<br />
45 155 185<br />
356 x 127 39 170 195<br />
33 195 225<br />
305 x 165 54 115 140<br />
46 130 160<br />
40 150 180<br />
305 x 127 48 125 145<br />
42 140 160<br />
37 155 180<br />
305 x 102 33 175 200<br />
28 200 225<br />
25 225 260<br />
254 x 146 43 120 150<br />
37 140 170<br />
31 160 200<br />
254 x 102 28 170 200<br />
25 190 220<br />
22 215 250<br />
203 x 133 30 145 180<br />
25 165 210<br />
203 x 102 23 175 210<br />
178 x 102 19 190 230<br />
152 x 89 16 190 235<br />
127 x 76 13 195 240<br />
Serial size Mass / metre 3 sides 4 sides<br />
mm kg m -1 m -1<br />
356 x 406 634 15 20<br />
551 20 25<br />
467 20 30<br />
393 25 35<br />
340 30 35<br />
287 30 45<br />
235 40 50<br />
356 x 368 202 45 60<br />
177 50 65<br />
153 55 75<br />
129 65 90<br />
305 x 305 283 30 40<br />
240 35 45<br />
198 40 50<br />
158 50 65<br />
137 55 70<br />
118 60 85<br />
97 75 100<br />
254 x 254 167 40 50<br />
132 50 65<br />
107 60 75<br />
89 70 90<br />
73 80 110<br />
203 x 203 86 60 80<br />
71 70 95<br />
60 80 110<br />
52 95 125<br />
46 105 140<br />
152 x 152 37 100 135<br />
30 120 160<br />
23 155 205<br />
Table 4 – Section factor A/V (Hp/A) of Universal Joists<br />
Serial size Mass / metre 3 sides 4 sides<br />
mm kg m -1 m -1<br />
254 x 203 82 70 90<br />
254 x 114 37 130 155<br />
203 x 152 52 85 105<br />
152 x 127 37 90 120<br />
127 x 114 30 100 130<br />
127 x 114 27 110 140<br />
114 x 114 27 100 135<br />
102 x 102 23 105 140<br />
89 x 89 19 105 145<br />
76 x 76 13 140 185<br />
Please refer to section 3 - Basic principles of system design for general guidance<br />
<strong>GypLyner</strong> <strong>ENCASE</strong><br />
403<br />
9
<strong>GypLyner</strong> <strong>ENCASE</strong><br />
9<br />
404<br />
Performance ( Refer to section 3 - Basic principles of system design)<br />
Section factor A/V (Hp/A) m -1<br />
260<br />
240<br />
220<br />
200<br />
180<br />
160<br />
140<br />
120<br />
100<br />
80<br />
60<br />
40<br />
20<br />
EN<br />
A<br />
Table 5 – The 550°C chart to<br />
ENV 13381-4 for selecting<br />
Gyproc FireLine lining thickness<br />
C<br />
91<br />
B<br />
52<br />
A<br />
30 60<br />
Fire protection (minutes)<br />
90 120<br />
Key - Thickness of Gyproc FireLine required1 System reference D150001<br />
NB<br />
B<br />
217<br />
A = 12.5mm<br />
B = 15mm<br />
C = 25mm (12.5mm + 12.5mm)<br />
D = 30mm (15mm + 15mm)<br />
E = 45mm (15mm + 15mm + 15mm)<br />
D<br />
154<br />
C<br />
E<br />
89<br />
D<br />
52<br />
C<br />
Table 6 – The 550°C chart to<br />
BS 476: Part 21 for selecting<br />
the required Gyproc FireLine<br />
lining thickness<br />
NBS work section K10 - Plasterboard drylinings / partitions / ceilings<br />
Section factor A/V (Hp/A) m -1<br />
260<br />
240<br />
220<br />
200<br />
180<br />
160<br />
140<br />
120<br />
100<br />
80<br />
60<br />
40<br />
20<br />
A<br />
A = 12.5mm<br />
B = 15mm<br />
C<br />
195<br />
B<br />
165<br />
A<br />
Fire protection (minutes)<br />
www.british-gypsum.com<br />
SPECSURE<br />
L I F E T I M E S Y S T E M W A R R A N T Y<br />
H<br />
30 60 90 120<br />
Key - Thickness of Gyproc FireLine required1 System reference D150001<br />
C = 25mm (12.5mm + 12.5mm)<br />
D = 27.5mm (15mm + 12.5mm)<br />
E = 30mm (15mm + 15mm)<br />
D<br />
200<br />
F = 37.5 (12.5mm + 12.5mm + 12.5mm)<br />
G = 40mm (15mm + 12.5mm + 12.5mm)<br />
H = 42.5mm (15mm + 15mm + 12.5mm)<br />
For improved durability and impact resistance, the outer layer of Gyproc FireLine can be replaced with a layer of 15mm Gyproc DuraLine.<br />
1 The fire protection is based on board joints being taped and filled, or skimmed according to <strong>British</strong> <strong>Gypsum</strong>’s recommendations.<br />
SPECSURE<br />
L I F E T I M E S Y S T E M W A R R A N T Y<br />
BS<br />
C<br />
225<br />
G<br />
190<br />
F<br />
110<br />
E
T 0844 800 1991 F 0844 561 8816 E bgtechnical.enquiries@bpb.com<br />
Section factor A/V (Hp/A) m -1<br />
260<br />
240<br />
220<br />
200<br />
180<br />
160<br />
140<br />
120<br />
100<br />
80<br />
60<br />
40<br />
20<br />
BS<br />
B<br />
230<br />
A<br />
System reference D150002<br />
A = 6mm<br />
B = 10mm<br />
C = 12.5mm<br />
Table 7 – The 550°C chart to<br />
BS 476: Part 8 for selecting<br />
Glasroc F MULTIBOARD lining<br />
thickness<br />
D<br />
180<br />
30 60 90<br />
Fire protection (minutes)<br />
Key - Thickness of Glasroc F MULTIBOARD required 1<br />
D = 20mm (10mm + 10mm)<br />
E = 25mm (12.5mm + 12.5mm)<br />
F = 30mm (10mm + 10mm + 10mm)<br />
G = 37.5mm (12.5mm + 12.5mm + 12.5mm)<br />
C<br />
140<br />
B<br />
F<br />
200<br />
E<br />
180<br />
D<br />
SPECSURE<br />
L I F E T I M E S Y S T E M W A R R A N T Y<br />
150<br />
G<br />
130<br />
F<br />
120<br />
180<br />
Fire protection (minutes)<br />
NBS work section K10 - Plasterboard drylinings / partitions / ceilings<br />
Section factor A/V (Hp/A) m -1<br />
140<br />
120<br />
100<br />
80<br />
60<br />
40<br />
20<br />
BS<br />
140<br />
D<br />
90<br />
80<br />
B<br />
60<br />
A<br />
C<br />
System reference D120003<br />
Table 8 – The 550°C chart to<br />
BS 476: Part 21 for selecting<br />
Glasroc F FIRECASE lining thickness<br />
Key - Thickness of Glasroc F FIRECASE required 1<br />
A = 35mm (20mm + 15mm)<br />
B = 40mm (20mm + 20mm)<br />
C = 45mm (25mm + 20mm)<br />
D = 50mm (25mm + 25mm)<br />
1 The fire protection is based on board joints being taped and filled, or skimmed according to <strong>British</strong> <strong>Gypsum</strong>’s recommendations.<br />
SPECSURE<br />
L I F E T I M E S Y S T E M W A R R A N T Y<br />
<strong>GypLyner</strong> <strong>ENCASE</strong><br />
405<br />
9
<strong>GypLyner</strong> <strong>ENCASE</strong><br />
9<br />
406<br />
Construction details<br />
1 Four-sided column encasement - single layer<br />
2<br />
3<br />
Three-sided beam encasement - single layer<br />
1 Structural steel<br />
2 Gyproc FireLine<br />
3 Gypframe GL1 Lining Channel<br />
4 Gypframe GL10 <strong>GypLyner</strong> Steel Framing Clip<br />
3<br />
1<br />
4<br />
5<br />
2<br />
1<br />
5<br />
2<br />
4<br />
3<br />
4<br />
5<br />
6<br />
7<br />
Four-sided column encasement - double layer<br />
Three-sided beam encasement - double layer<br />
Gypframe GL1 Lining Channel nogging or Gypframe<br />
GFT1 Fixing ‘T’ board joints<br />
Gypframe GFS1 Fixing Strap<br />
Gypframe GA2 Steel Angle<br />
www.british-gypsum.com<br />
7 7<br />
3<br />
1<br />
4<br />
6<br />
2<br />
1<br />
6<br />
2<br />
4<br />
3
T 0844 800 1991 F 0844 561 8816 E bgtechnical.enquiries@bpb.com<br />
5<br />
7<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
Column encasement and partition junction<br />
Boxing out for columns up to 600mm wide using <strong>GypLyner</strong> IWL<br />
Structural steel<br />
Gyproc FireLine<br />
Gypframe GL1 Lining Channel<br />
Gypframe GL10 <strong>GypLyner</strong> Steel Framing Clip<br />
Gypframe GL1 Lining Channel nogging or Gypframe<br />
GFT1 Fixing ‘T’ board joints<br />
Gypframe GFS1 Fixing Strap<br />
1<br />
2<br />
5<br />
9<br />
8<br />
10<br />
4<br />
3<br />
10<br />
1<br />
10<br />
2<br />
6<br />
6<br />
8<br />
Beam encasement and partition junction<br />
Boxing out for columns over 600mm wide using <strong>GypLyner</strong> IWL<br />
7 Gypframe GA2 Steel Angle<br />
8 Gypframe GL1 Lining Channel nogging at 600mm centres<br />
9 Gyproc plasterboard<br />
10 Gypframe ‘C’ Studs<br />
11 Gypframe Standard Floor & Ceiling Channel<br />
12<br />
Gypframe ‘I’ Stud at 600mm centres<br />
7<br />
1<br />
5<br />
2<br />
8<br />
4<br />
2<br />
11<br />
9<br />
10<br />
10<br />
12<br />
1<br />
10<br />
8<br />
<strong>GypLyner</strong> <strong>ENCASE</strong><br />
407<br />
9