ID Category Construction Name<br />

518 Pitched roof,<br />

horizontal insulation<br />

Pitched roof (SCO) 1997-<br />

2001<br />

U-value κm1 κm2 Metal-<br />

[W/m 2 K] [kJ/m 2 K] [kJ/m 2 K] cladding<br />

0.25 12 12 NO<br />

519 Solid ground floor Ground floor (SCO) pre-<br />

1975<br />

1.14 22.5 92.5 NO<br />

520 Suspended floor Suspended ground floor<br />

(SCO) 1975-1981<br />

1 22.5 92.5 NO<br />

521 Suspended floor Suspended ground floor<br />

(SCO) 1982-1990<br />

0.6 22.5 22.5 NO<br />

522 Suspended floor Suspended ground floor<br />

(SCO) 1991-1996<br />

0.45 22.5 22.5 NO<br />

523 Suspended floor Suspended ground floor<br />

(SCO) 1997-2001<br />

0.45 6.75 6.75 NO<br />

524 Flat roof Flat roof (SCO) pre-1975 1.14 8.55 11.17 NO<br />

525 Flat roof Flat roof (SCO) 1975-<br />

1981<br />

0.6 8.55 11.17 NO<br />

526 Flat roof Flat roof (SCO) 1982-<br />

1990<br />

0.45 8.55 8.55 NO<br />

527 Flat roof Flat roof (SCO) 1991-<br />

1996<br />

0.45 12.45 12.45 NO<br />

528 Flat roof Flat roof (SCO) 1997-<br />

2001<br />

0.45 50.9 190.9 NO<br />

529 Flat roof Flat roof (SCO) 2002-<br />

2006<br />

0.45 72 240 NO<br />

530 Pitched roof,<br />

insulation at rafters<br />

531 Pitched roof,<br />

insulation at rafters<br />

532 Pitched roof,<br />

insulation at rafters<br />

533 Pitched roof,<br />

insulation at rafters<br />

534 Pitched roof,<br />

insulation at rafters<br />

535 Pitched roof,<br />

horizontal insulation<br />

Pitched roof, insul. at<br />

rafters (SCO) 1975-1981<br />

Pitched roof, insul. at<br />

rafters (SCO) 1982-1990<br />

Pitched roof, insul. at<br />

rafters (SCO) 1991-1996<br />

Pitched roof, insul. at<br />

rafters (SCO) 1997-2001<br />

Pitched roof, insul. at<br />

rafters (SCO) 2002-2006<br />

Pitched roof (SCO) 2002-<br />

2006<br />

536 Suspended floor Semi-exposed floor<br />

(SCO) 1982-1990<br />

537 Suspended floor Semi-exposed floor<br />

(SCO) 1991-1996<br />

538 Suspended floor Semi-exposed floor<br />

(SCO) 1997-2001<br />

539 Cavity wall (partial<br />

fill)<br />

540 Cavity wall (partial<br />

fill)<br />

541 Cavity wall (partial<br />

fill)<br />

Semi-exposed wall<br />

(SCO) 1982-1990<br />

Semi-exposed wall<br />

(SCO) 1991-1996<br />

Semi-exposed wall<br />

(SCO) 1997-2001<br />

542 Solid (masonry) wall Solid wall (SCO) 1991-<br />

1996<br />

39<br />

0.6 12 12 NO<br />

0.45 12 12 NO<br />

0.45 12 12 NO<br />

0.45 12 12 NO<br />

0.25 12 12 NO<br />

0.16 12 12 NO<br />

0.7 22.5 22.5 NO<br />

0.6 22.5 22.5 NO<br />

0.6 6.75 6.75 NO<br />

0.7 47.5 173.5 NO<br />

0.6 42.84 142.8 NO<br />

0.6 42.84 142.8 NO<br />

0.45 54 180 NO