National Calculation Methodology (NCM) - Scottish Government
National Calculation Methodology (NCM) - Scottish Government
National Calculation Methodology (NCM) - Scottish Government
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
ID Category Construction Name<br />
518 Pitched roof,<br />
horizontal insulation<br />
Pitched roof (SCO) 1997-<br />
2001<br />
U-value κm1 κm2 Metal-<br />
[W/m 2 K] [kJ/m 2 K] [kJ/m 2 K] cladding<br />
0.25 12 12 NO<br />
519 Solid ground floor Ground floor (SCO) pre-<br />
1975<br />
1.14 22.5 92.5 NO<br />
520 Suspended floor Suspended ground floor<br />
(SCO) 1975-1981<br />
1 22.5 92.5 NO<br />
521 Suspended floor Suspended ground floor<br />
(SCO) 1982-1990<br />
0.6 22.5 22.5 NO<br />
522 Suspended floor Suspended ground floor<br />
(SCO) 1991-1996<br />
0.45 22.5 22.5 NO<br />
523 Suspended floor Suspended ground floor<br />
(SCO) 1997-2001<br />
0.45 6.75 6.75 NO<br />
524 Flat roof Flat roof (SCO) pre-1975 1.14 8.55 11.17 NO<br />
525 Flat roof Flat roof (SCO) 1975-<br />
1981<br />
0.6 8.55 11.17 NO<br />
526 Flat roof Flat roof (SCO) 1982-<br />
1990<br />
0.45 8.55 8.55 NO<br />
527 Flat roof Flat roof (SCO) 1991-<br />
1996<br />
0.45 12.45 12.45 NO<br />
528 Flat roof Flat roof (SCO) 1997-<br />
2001<br />
0.45 50.9 190.9 NO<br />
529 Flat roof Flat roof (SCO) 2002-<br />
2006<br />
0.45 72 240 NO<br />
530 Pitched roof,<br />
insulation at rafters<br />
531 Pitched roof,<br />
insulation at rafters<br />
532 Pitched roof,<br />
insulation at rafters<br />
533 Pitched roof,<br />
insulation at rafters<br />
534 Pitched roof,<br />
insulation at rafters<br />
535 Pitched roof,<br />
horizontal insulation<br />
Pitched roof, insul. at<br />
rafters (SCO) 1975-1981<br />
Pitched roof, insul. at<br />
rafters (SCO) 1982-1990<br />
Pitched roof, insul. at<br />
rafters (SCO) 1991-1996<br />
Pitched roof, insul. at<br />
rafters (SCO) 1997-2001<br />
Pitched roof, insul. at<br />
rafters (SCO) 2002-2006<br />
Pitched roof (SCO) 2002-<br />
2006<br />
536 Suspended floor Semi-exposed floor<br />
(SCO) 1982-1990<br />
537 Suspended floor Semi-exposed floor<br />
(SCO) 1991-1996<br />
538 Suspended floor Semi-exposed floor<br />
(SCO) 1997-2001<br />
539 Cavity wall (partial<br />
fill)<br />
540 Cavity wall (partial<br />
fill)<br />
541 Cavity wall (partial<br />
fill)<br />
Semi-exposed wall<br />
(SCO) 1982-1990<br />
Semi-exposed wall<br />
(SCO) 1991-1996<br />
Semi-exposed wall<br />
(SCO) 1997-2001<br />
542 Solid (masonry) wall Solid wall (SCO) 1991-<br />
1996<br />
39<br />
0.6 12 12 NO<br />
0.45 12 12 NO<br />
0.45 12 12 NO<br />
0.45 12 12 NO<br />
0.25 12 12 NO<br />
0.16 12 12 NO<br />
0.7 22.5 22.5 NO<br />
0.6 22.5 22.5 NO<br />
0.6 6.75 6.75 NO<br />
0.7 47.5 173.5 NO<br />
0.6 42.84 142.8 NO<br />
0.6 42.84 142.8 NO<br />
0.45 54 180 NO