ID Category Construction Name<br />

422 Vehicle access door Vehicle access door<br />

(SCO) 2002 Part J<br />

455 Suspended floor Exposed floor (SCO)<br />

1997 Part J<br />

456 Suspended floor Exposed floor (SCO)<br />

2002 Section 6<br />

457 Suspended floor Exposed floor (SCO)<br />

2007 Section 6<br />

458 Timber frame wall Timber frame wall (SCO)<br />

1997 Part J (S)<br />

459 Timber frame wall Timber frame wall (SCO)<br />

2002 Part J<br />

460 Timber frame wall Timber frame wall (SCO)<br />

2006 Section 6<br />

468 Timber frame wall Timber frame wall (SCO)<br />

1991 Part J<br />

502 Curtain wall Curtain wall (SCO) 2007<br />

Section 6 (gas heating)<br />

503 Flat roof Flat roof (SCO) 2007<br />

Section 6 (gas heating)<br />

504 Non-structural roof<br />

(metal) cladding<br />

system<br />

505 Non-structural wall<br />

(metal) cladding<br />

system<br />

506 Pitched roof,<br />

horizontal insulation<br />

Metal cladding roof<br />

(SCO) 2007 Section 6<br />

Metal cladding wall<br />

(SCO) 2007 Section 6<br />

Pitched roof (SCO) 2007<br />

Section 6<br />

507 Solid (masonry) wall Solid wall (SCO) 2007<br />

Section 6<br />

508 Solid ground floor Solid ground floor (SCO)<br />

2007 Section 6:<br />

509 Cavity wall (clear) Clear cavity wall (SCO)<br />

pre-1975<br />

510 Cavity wall (clear) Clear cavity wall (SCO)<br />

1975-1981<br />

511 Cavity wall (partial<br />

fill)<br />

512 Cavity wall (partial<br />

fill)<br />

513 Cavity wall (partial<br />

fill)<br />

514 Pitched roof,<br />

horizontal insulation<br />

515 Pitched roof,<br />

horizontal insulation<br />

516 Pitched roof,<br />

horizontal insulation<br />

517 Pitched roof,<br />

horizontal insulation<br />

Cavity wall (SCO) 1982-<br />

1990<br />

Cavity wall (SCO) 1991-<br />

1996<br />

Cavity wall (SCO) 1997-<br />

2001<br />

Pitched roof (SCO) pre-<br />

1975<br />

Pitched roof (SCO) 1975-<br />

1981<br />

Pitched roof (SCO) 1982-<br />

1990<br />

Pitched roof (SCO) 1991-<br />

1996<br />

38<br />

U-value κm1 κm2 Metal-<br />

[W/m 2 K] [kJ/m 2 K] [kJ/m 2 K] cladding<br />

1.5 4.93 4.93 NO<br />

0.45 15 15 NO<br />

0.25 15 15 NO<br />

0.22 15 15 NO<br />

0.45 12 12 NO<br />

0.3 12 12 NO<br />

0.3 12 12 NO<br />

0.45 12 12 NO<br />

1.2 4 4 NO<br />

0.16 50.9 190.9 NO<br />

0.25 7 7 YES<br />

0.25 1.4 1.4 YES<br />

0.13 12 12 NO<br />

0.25 54 180 NO<br />

0.22 36 60 NO<br />

2.4 47.5 173.5 NO<br />

1 47.5 173.5 NO<br />

0.6 47.5 173.5 NO<br />

0.45 42.84 142.8 NO<br />

0.45 42.84 142.8 NO<br />

1.14 12 12 NO<br />

0.6 12 12 NO<br />

0.45 12 12 NO<br />

0.25 12 12 NO