A.8. HOUSEKEEPING FILES 79<br />
A.8 Housekeeping Files<br />
A.8.1 Americium Survey DPHs<br />
Americium tagged source surveys (code “amcb,” suffix “dph”). Tagged calibration source events<br />
are segregated from normal events and binned in separate DPHs. <strong>The</strong> format is the same as the<br />
normal survey DPH, but the duration is much longer (typically 90 minutes). And since the tagged<br />
source position is fixed with respect to the detector plane, Am241 surveys can span pointings.<br />
<strong>The</strong>se are used by the <strong>BAT</strong> team to derive the absolute energy calibration of the experiment.<br />
A.8.2 Americium Block Spectra<br />
Americium block spectra (code “amcb,” suffix “fits”) are eighty-channel histograms of tagged source<br />
events reported for each of the sixteen blocks. <strong>The</strong>se are produced on the same time scale as the<br />
normal surveys (as opposed to Am241 surveys).<br />
A.8.3 Calibration Pulser Maps<br />
Calibration maps (code “cb,” suffix “dph”) contain the raw results from the pulser calibration runs<br />
used in on-board calibration. <strong>The</strong>y are used by the <strong>BAT</strong> team to check the on-board calibration.<br />
Also if a series of more than two calibrations is commanded, the resulting calibration maps can be<br />
used to determine the nonlinearity of the energy calibration.<br />
A.8.4 Detector Array Panel (DAP) Housekeeping<br />
<strong>The</strong> DAP houskeeping file (code “dp”) contains high level housekeeping values that pertain to the<br />
entire array.<br />
Layout. DAP Housekeeping EXTNAME = ‘DAP HK’<br />
Name Format [Units] Comment<br />
TIME 1D [s] Mission TIME in seconds<br />
BStatus DMRcvrOver (16,16)X DM Reciever Overflow Flags<br />
BStatus CtrlSigStat (16,16)X Control Signal Status<br />
BStatus DMRDataErr (16,16)X DM Receiver Parity/Data Code Error<br />
BStatus DataStat (16,16)X ADC Latchup / Overflow / FIFO Status<br />
BStatus DMTimeOut (16,16)X DM Timeout/Invalid Command Flags<br />
BStatus SPWStatA (16,16)X SpaceWire Status Register A<br />
BStatus SPWOverErr 16B SpaceWire Overflow Error Count<br />
BStatus SPWEOP2Err 16B SpaceWire EOP2 Error Count<br />
BStatus SPWFrmgErr 16B SpaceWire Framing Error Count<br />
BStatus SPWStatB (16,16)X SpaceWire Status Register B<br />
BStatus SPWClrRErr 16B SpaceWire Cleared Receiver Error Ct<br />
BStatus SPWClrPErr 16B SpaceWire Clear Partial Pkt Error Ct<br />
BBiasVolt IbPre 16I [uA] IbPre Bias Voltage ADC Value<br />
BBiasVolt IbSha 16I [uA] IbSha Bias Voltage ADC Value<br />
BBiasVolt IbOTA 16I [uA] IbOTA Bias Voltage ADC Value<br />
BBiasVolt IbDAC 16I [uA] IbDAC Bias Voltage ADC Value<br />
BBiasVolt IbTDB 16I [uA] IbTDB Bias Voltage ADC Value<br />
BBiasVolt IbRWB 16I [uA] IbRWB Bias Voltage ADC Value