Chapter 6<br />
<strong>BAT</strong> Analysis Issues<br />
6.1 Introduction<br />
This chapter contains various science analysis issues that may come up during analysis. In some<br />
cases, the issues represent “bugs” in the software, which are usually corrected in later software<br />
releases. In other cases, the issue may reflect a “gotcha” or other subtle problem that needs special<br />
attention.<br />
<strong>The</strong> chapter is organized into two sections. <strong>The</strong> first section contains “current” issues that<br />
may affect analysis of data in the archive today, using recently available software. Users should<br />
definitely consult this first section for any issues that might affect their data analysis.<br />
<strong>The</strong> second section contains older issues that are not likely to affect present-day analysis. This<br />
involves softare bugs that have been fixed more than a year ago, Swift Data Center problems that<br />
have been fixed, and other issues that have since been resolved.<br />
Each issue contains vital information, such as the versions of the software and which tasks it<br />
affects, the status of the issue, and a more complete narrative about the problem.<br />
6.2 Current Issues<br />
6.2.1 batoccultgti: Fails when checking the field of view only<br />
Task: batoccultgti<br />
<strong>Version</strong>: 2.3 and earlier<br />
What builds: HEASoft <strong>6.3</strong>.1 and earlier<br />
Problem: batoccultgti reports an error ”could not create ’’”<br />
Status: Workaround<br />
Updated: <strong>30</strong> Jul 2007<br />
<strong>The</strong> task batoccultgti can be used to select times when a particular source is both unocculted<br />
by the earth, and in the field of view. <strong>The</strong>re are several field of view selection criteria, including<br />
both partial coding and instrument coordinates such as IMX, IMY, and theta.<br />
However, if the user selects only instrument coordinate constraints, then batoccultgti will report<br />
the following error:<br />
ERROR: could not create ’’ at /path/name/...<br />
Task batoccultgti 2.3 terminating with status -1<br />
55