The SWIFT BAT Software Guide Version 6.3 30 ... - HEASARC - Nasa
The SWIFT BAT Software Guide Version 6.3 30 ... - HEASARC - Nasa
The SWIFT BAT Software Guide Version 6.3 30 ... - HEASARC - Nasa
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
98 APPENDIX D. <strong>BAT</strong> SOFTWARE TOOL REFERENCE<br />
(ecol = PI) [string ]<br />
Column name to use for the energy value. <strong>The</strong> default is the energy computed in the “PI”<br />
column, but it is possible to choose another column name such as “PHA”.<br />
(weighted = INDEF) [string ]<br />
Set to boolean yes or no (or INDEF), depending on whether mask weighting should be applied<br />
to the binning operation. A value of “no” indicates that all counts should be unweighted<br />
(unity weight). A value of INDEF depends on outtype. If outtype is LC or PHA, then<br />
INDEF signifies that “yes,” weighting should be applied; for output types DPH, DPI or<br />
DPITAB, then INDEF means “no” weighting should be applied.<br />
(outunits = INDEF) [string ]<br />
Set to RATE, COUNTS or INDEF, depending on whether the output histogram units should<br />
be “count/s”, “count”, or automatically determined (INDEF). When INDEF is specified,<br />
outunit depends on outype. If outtype is LC or PHA, then INDEF signifies “RATE;” for<br />
output types DPH, DPI or DPITAB, then INDEF means “COUNTS.” Note that not all<br />
combinations are meaningful.<br />
(timepixr = -1.0) [real ]<br />
Determines the reference point of each time bin for light curves only. A value of 0.0 (0.5)<br />
indicates that the TIME column refers to the start (center) of each time bin. A special<br />
value of -1 (the default) specifies that timepixr=0.0 for uniformly binned light curves and<br />
timepixr=0.5 for non-unformly binned light curves. This parameter does not have any affect<br />
for spectra, images or DPHs.<br />
(maskwt = NONE) [string ]<br />
Mask weight map file. This file should contain a mask weight image for the detector plane,<br />
and if given, overrides any mask weighting found in the infile.<br />
(tstart = INDEF) [string ]<br />
Start time of the accumulation, in seconds, expressed in Mission Elapsed Time. Default value<br />
(INDEF) implies using the TSTART/TSTOP keywords from the input file.<br />
(tstop = INDEF) [string ]<br />
Stop time of the accumulation, in seconds, expressed in Mission Elapsed Time. Default value<br />
(INDEF) implies using the TSTART/TSTOP keywords from the input file.<br />
(snrthresh = 6.0) [real ]<br />
For the constsnr binning method, the signal to noise ratio to require for each time bin. If<br />
there is more than one energy bin selected, the threshold refers to the signal to noise ratio<br />
for the sum of all energy bins.<br />
(detmask = “NONE”) [string ]<br />
Name of a detector quality map file. This should be an image file with the same dimensions<br />
as the detector plane map. A pixel value of 0 indicates the detector is enabled for imaging,<br />
and a non-zero value indicates disabled. A default value of NONE implies all detectors are<br />
on, except for the <strong>BAT</strong> detector gap regions.<br />
(tcol = “TIME”) [string ]<br />
Name of TIME column in input file.