98 APPENDIX D. <strong>BAT</strong> SOFTWARE TOOL REFERENCE<br />

(ecol = PI) [string ]<br />

Column name to use for the energy value. <strong>The</strong> default is the energy computed in the “PI”<br />

column, but it is possible to choose another column name such as “PHA”.<br />

(weighted = INDEF) [string ]<br />

Set to boolean yes or no (or INDEF), depending on whether mask weighting should be applied<br />

to the binning operation. A value of “no” indicates that all counts should be unweighted<br />

(unity weight). A value of INDEF depends on outtype. If outtype is LC or PHA, then<br />

INDEF signifies that “yes,” weighting should be applied; for output types DPH, DPI or<br />

DPITAB, then INDEF means “no” weighting should be applied.<br />

(outunits = INDEF) [string ]<br />

Set to RATE, COUNTS or INDEF, depending on whether the output histogram units should<br />

be “count/s”, “count”, or automatically determined (INDEF). When INDEF is specified,<br />

outunit depends on outype. If outtype is LC or PHA, then INDEF signifies “RATE;” for<br />

output types DPH, DPI or DPITAB, then INDEF means “COUNTS.” Note that not all<br />

combinations are meaningful.<br />

(timepixr = -1.0) [real ]<br />

Determines the reference point of each time bin for light curves only. A value of 0.0 (0.5)<br />

indicates that the TIME column refers to the start (center) of each time bin. A special<br />

value of -1 (the default) specifies that timepixr=0.0 for uniformly binned light curves and<br />

timepixr=0.5 for non-unformly binned light curves. This parameter does not have any affect<br />

for spectra, images or DPHs.<br />

(maskwt = NONE) [string ]<br />

Mask weight map file. This file should contain a mask weight image for the detector plane,<br />

and if given, overrides any mask weighting found in the infile.<br />

(tstart = INDEF) [string ]<br />

Start time of the accumulation, in seconds, expressed in Mission Elapsed Time. Default value<br />

(INDEF) implies using the TSTART/TSTOP keywords from the input file.<br />

(tstop = INDEF) [string ]<br />

Stop time of the accumulation, in seconds, expressed in Mission Elapsed Time. Default value<br />

(INDEF) implies using the TSTART/TSTOP keywords from the input file.<br />

(snrthresh = 6.0) [real ]<br />

For the constsnr binning method, the signal to noise ratio to require for each time bin. If<br />

there is more than one energy bin selected, the threshold refers to the signal to noise ratio<br />

for the sum of all energy bins.<br />

(detmask = “NONE”) [string ]<br />

Name of a detector quality map file. This should be an image file with the same dimensions<br />

as the detector plane map. A pixel value of 0 indicates the detector is enabled for imaging,<br />

and a non-zero value indicates disabled. A default value of NONE implies all detectors are<br />

on, except for the <strong>BAT</strong> detector gap regions.<br />

(tcol = “TIME”) [string ]<br />

Name of TIME column in input file.