Partial coding Indicates the fractional illumination of the detector array by an off-axis source.<br />
Phi For a position in the <strong>BAT</strong> field of view, the longitude of the position, as measured from the<br />
<strong>BAT</strong> X axis.<br />
PSF Point spread function, the spatial response of the instrument to an incident point source.<br />
Pulser Electronic device used to calibrate the <strong>BAT</strong> electronic pulse height scale. Periodic pulser<br />
calibration cycles are used to produce a calibration pulser map (trend product). <strong>The</strong>se maps<br />
are used to update the gain/offset map.<br />
Quadrant Rates A type of light curve produced by the <strong>BAT</strong>, which contains the count rates in<br />
each of four geographic quadrants of the detector array (also “quad rates”).<br />
Quality Map Detector map produced on the ground, which combines information about disabled/enabled<br />
detectors, and noisy detectors discovered in post-processing.<br />
SAA South Atlantic Anomaly, region of high ionizing radiation in low earth orbit. <strong>The</strong> <strong>BAT</strong> does<br />
not typically produce science data during SAA passes.<br />
Sandwich same as DM Side.<br />
Segment see Observation Segment.<br />
Snapshot Swift name for a single contiguous pointed observation at a target, usually between 5<br />
and 20 minutes in duration. See also “Observation Segment.”<br />
Spacewire communication bus connecting <strong>BAT</strong> blocks to the Image Processor.<br />
SSR Solid State Recorder, the spacecraft on-board storage system.<br />
Survey image data collected while waiting for the next GRB (in the form of DPHs).<br />
Tagged Source Radioactive 241 Am calibration source used for on-board <strong>BAT</strong> calibration.<br />
Target number a unique number assigned to Swift observations of a single object, such as a<br />
gamma-ray burst or other astrophysical object. Long or disjoint observations may be split<br />
into different observation segments with different segment numbers, but they should all have<br />
the same target number.<br />
<strong>The</strong>ta For a position in the <strong>BAT</strong> field of view, the angle between the <strong>BAT</strong> boresight and the<br />
position (i.e., co-latitude).<br />
UVOT Ultra-Violet Optical Telescope, the UV/Optical instrument aboard Swift.<br />
XRT X-Ray Telescope, the X-ray instrument aboard Swift.<br />