6.3 Changing the mode 6. Enter the import options (see also Fig. 10551): - "Separator": enter the character that separates the individual texts in one line, e. g. ;. The entire text between separators is inserted into a text field of the mask. - "Active line number": enter the line number of the file with the data to be imported. Each line of the file is used as a mask. - "Strip spaces": select if you don't want to mark leading space characters. - "Delete file when done": select if the file is to be deleted after the import. 7. Select . "Preview" appears. Since the marking speed is by default set to 0 mm/s in new text fields, the text in the preview is displayed in blue colour. 8. Select Edit and enter a marking speed "V [mm/s]" > 0. 3 different modes are available at the control: • Work mode: files (projects and masks) can be loaded and marked. • Edit mode: files (projects and masks) can be loaded, changed and marked. It is also possible to create new masks and projects. • Service mode: all operating functions are possible. E. g. also system parameters can be changed. The mode of the control can be changed at any time. If the edit and/or service mode is protected with a password, (see page 4-45), the password must be entered. 1. Select Edit > Mode. "Password Dialog" appears. 2. Select the desired mode. 3. If the desired mode is protected with a password, you have to enter the password: enter password. 4. Select . Control is changed to the selected mode. B_PM_UMC112_en04.doc 4-28 Operation ÖSTLING Markiersysteme GmbH

7 System control 7.1 Reading out diagnostic data � Select System > Diagnostic. "Diagnostic" appears. Mask "Diagnostic" Fig. 10552en • Pinware Version: software version that is installed on the control. • Install Version: version of the compact flash card. • Firmware Version: software version of the motor card. • Ambient/Heat sink temperature: temperature of the ambient air in [°C] and temperature of the heat sink of the motor card in [°C]. B_PM_UMC112_en04.doc ÖSTLING Markiersysteme GmbH Operation 4-29

7 System control<br />

7.1 Reading out diagnostic data<br />

� Select System > Diagnostic.<br />

"Diagnostic" appears.<br />

Mask "Diagnostic" Fig. 10552en<br />

• Pinware Version: software version that is installed on the control.<br />

• Install Version: version of the compact flash card.<br />

• Firmware Version: software version of the motor card.<br />

• Ambient/Heat sink temperature: temperature of the ambient air in [°C] and<br />

temperature of the heat sink of the motor card in [°C].<br />

B_PM_<strong>UMC</strong><strong>112</strong>_en04.doc<br />

ÖSTLING Markiersysteme GmbH Operation 4-29