1.2 PLC operation (option)<br />

Loading a mask via PLC<br />

Conversion of<br />

binary numbers<br />

Process<br />

With this option one mask out of up to 127 masks (files with ending *.msk) can<br />

be selected and loaded via a PLC (programmable logic control).<br />

The number of the mask is transferred binary coded. The order of the masks is<br />

determined in System > Options on the tab "File selection" (see chapter 4).<br />

Binary numbers can be simply converted into decimal numbers. The value of a<br />

binary number results from summating its digits that are previously multiplied<br />

with its place value 2 i :<br />

Example: [101]2 = 1*2 2 + 0*2 1 + 1*2 0 = [5]10<br />

[1111110]2 = 1*2 6 + 1*2 5 + 1*2 4 + 1*2 3 + 1*2 2 + 1*2 1 + 0*2 0 = [126]10<br />

The number of the mask to be loaded must be pending stably at the inputs E2.0<br />

to E2.6 at least 100 ms before data transfer:<br />

Mask to<br />

load<br />

E2.6 E2.5 E2.4 E2.3 E2.2 E2.1 E2.0<br />

1 0 0 0 0 0 0 1<br />

2 0 0 0 0 0 1 0<br />

3 0 0 0 0 0 1 1<br />

4 0 0 0 0 1 0 0<br />

5 0 0 0 0 1 0 1<br />

...<br />

127 1 1 1 1 1 1 1<br />

Tab. 15<br />

If the data are pending stably the input E2.7 (data transfer) operates. For<br />

validation the control sets the output A2.0 (data transferred) until the selected<br />

mask is available for marking, but for at least 200 ms. If less masks are saved<br />

than the transferred number demands, the control sets the output A2.1 (error<br />

data transfer). This error is pending with A2.0 (data transferred), until it is<br />

acknowledged by pressing of any button at the control or by setting of the input<br />

E1.6 (acknowledge error).<br />

Note<br />

With the optional digit encoding switch number >127 are interpreted as 127. As<br />

hundreds you can only select 0 and 1.<br />

B_PM_<strong>UMC</strong><strong>112</strong>_en06.doc<br />