Load text<br />
With this function, text fields are sent to the control via the serial port and inserted<br />
into the actual mask. After an error-free data transfer the control is "Ready<br />
to mark", the sent test can be marked.<br />
To load a text field, the following data must be sent:<br />
1. Byte 2. Byte 3. Byte 4. Byte 5. Byte 6. Byte 7. Byte 8. Byte<br />
HEX 01h 54h 44h 1Ah 30h 31h 17h 04h<br />
DEC 01 84 68 26 48 49 23 04<br />
ASCII SOH 'T' 'D' SUB '0' '1' ETB EOT<br />
Start of<br />
header<br />
Text Download <br />
Substitute<br />
No. of the text field,<br />
e. g. text field 01<br />
End of<br />
transfered<br />
block<br />
End of<br />
transfer<br />
Tab. 9<br />
If the control has received the header and is "Ready to mark", it sends the following:<br />
1. Byte 2. Byte 3. Byte 4. Byte 5. Byte 6. Byte 7. Byte 8. Byte<br />
HEX 01h 54h 44h 06h 30h 31h 17h 04h<br />
DEC 01 84 68 06 48 49 23 04<br />
ASCII SOH 'T' 'D' ACK '0' '1' ETB EOT<br />
Start of<br />
header<br />
Text Download <br />
Acknowledge<br />
No. of the text field,<br />
e. g. text field 01<br />
End of<br />
transfered<br />
block<br />
End of<br />
transfer<br />
If the control has received the header and is not ready, it sends the following:<br />
Tab. 10<br />
1. Byte 2. Byte 3. Byte 4. Byte 5. Byte 6. Byte 7. Byte 8. Byte<br />
HEX 01h ??h ??h 15h 30h 31h 17h 04h<br />
DEC 01 21 48 49 23 04<br />
ASCII SOH 'E' 'R' NAK '0' '1' ETB EOT<br />
Start of<br />
header<br />
Error Error No acknowledg<br />
ment<br />
No. of the text field,<br />
e. g. text field 01<br />
The superior control then sends the text of the text field:<br />
1. Byte 2. to n. Byte n+1. Byte<br />
HEX 02h 04h<br />
DEC 02 04<br />
ASCII STX EOT<br />
Start of text desired text (max. 50<br />
ASCII characters)<br />
End of<br />
transfered<br />
block<br />
End of transfer<br />
End of<br />
transfer<br />
Tab. 11<br />
Tab. 12<br />
B_PM_<strong>UMC</strong><strong>112</strong>_en06.doc<br />
ÖSTLING Markiersysteme GmbH Communication 6-7