Load mask<br />
Error<br />
With this function a mask is called up via the serial port. The mask to be called<br />
must be already stored on the control. To load a mask, the following data must<br />
be sent:<br />
1. Byte 2. Byte 3. Byte 4. Byte 5. - 16. Byte 7. Byte 8. Byte<br />
HEX 01h 4Dh 4Ch 1Ah 12 Bytes 17h 04h<br />
DEC 01 77 76 26 23 04<br />
ASCII SOH 'M' 'L' SUB TEST .MSK ETB EOT<br />
Start of<br />
header<br />
Mask Laden Substitute<br />
File name of the<br />
mask e. g.<br />
'Test.msk'<br />
End of<br />
transfered<br />
block<br />
End of<br />
transfer<br />
Tab. 5<br />
Note<br />
The file name must be filled with spaces up to 8 characters ahead of the point.<br />
After error-free reception of the data the control sends the following:<br />
1. Byte 2. Byte 3. Byte 4. Byte 5. - 16. Byte 7. Byte 8. Byte<br />
HEX 01h 4Dh 4Ch 06h 12 Bytes 17h 04h<br />
DEC 01 77 76 06 23 04<br />
ASCII SOH 'M' 'L' ACK TEST .MSK ETB EOT<br />
Start of<br />
header<br />
Mask Laden Acknowledge<br />
File name of the<br />
mask e. g.<br />
'Test.msk'<br />
If the mask isn't available, the control sends the following:<br />
End of<br />
transfered<br />
block<br />
End of<br />
transfer<br />
Tab. 6<br />
1. Byte 2. Byte 3. Byte 4. Byte 5. - 16. Byte 7. Byte 8. Byte<br />
HEX 01h 30h 35h 15h 12 Bytes 17h 04h<br />
DEC 01 48 53 21 23 04<br />
ASCII SOH '0' '5' NAK TEST .MSK ETB EOT<br />
Start of<br />
header<br />
Incoming byte in<br />
hexadecimal format<br />
No acknowledg<br />
ment<br />
File name of the<br />
mask e. g.<br />
'Test.msk'<br />
If the received header is defective, the control sends the following:<br />
End of<br />
transfered<br />
block<br />
End of<br />
transfer<br />
Tab. 7<br />
1. Byte 2. Byte 3. Byte 4. Byte 5. - 16. Byte 7. Byte 8. Byte<br />
HEX 01h 30h 31h 15h 12 Bytes 17h 04h<br />
DEC 01 48 49 21 23 04<br />
ASCII SOH '0' '1' NAK TEST .MSK ETB EOT<br />
Start of<br />
header<br />
Incoming byte in<br />
hexadecimal format<br />
No acknowledg<br />
ment<br />
File name of the<br />
mask e. g.<br />
'Test.msk'<br />
End of<br />
transfered<br />
block<br />
End of<br />
transfer<br />
Tab. 8<br />
B_PM_<strong>UMC</strong><strong>112</strong>_en06.doc<br />
6-6 Communication ÖSTLING Markiersysteme GmbH