EFC RDS Fired e. Leave blank.<br />

Cumulative RDS Fired f. Leave blank.<br />

Cumulative EFC RDS g. Leave blank.<br />

Remaining Life EFC RDS h. Leave blank.<br />

Remarks i. For M1, enter boresights and zero information. For M109A6 Paladin, enter Measured Correction and AFCS offsets. Record<br />

all boresight and zero data for different type ammunition being fired. For M109A6, enter Measured Correction and AFCS offsets each<br />

time a Fire Control alignment is performed.<br />

Signature j. <strong>The</strong> person doing the boresight and zeroing signs and enters rank.<br />

Figure 5–3. Sample DA Form 2408–4 used for boresight and zero<br />

Notes:<br />

1 When DA Form 2408–4 is filled up and after the information has been transcribed to a new DA Form 2408–4, keep the old form for 90 days, and then<br />

destroy.<br />

2 When it is necessary to replace the entire weapon, forward the up-to-date DA Form 2408–4 with the unserviceable weapon.<br />

Legend for Figure 5–4;<br />

completion instructions follow.<br />

1. TUBE SERIAL NUMBER. No entry required.<br />

2. CANNON TYPE MODEL OR SERIES. Enter Gun, 25mm, M242.<br />

3. ORGANIZATION (UIC). Enter owning organization name and unit identification code.<br />

4. SPECIAL LIFE DATA. Dry fire is currently not accounted for. Entry for dry fire accountability is no longer required. If an individual unit<br />

desires to keep this information, it is its decision. Enter replace breach at 25,000 rounds and replace firing pin (PN 12524325) at 8,000<br />

rounds, and (PN 12524512) every 12,000 rounds.<br />

5. END ITEM IDENTIFICATION. Enter the vehicle identification, Model and vehicle chassis serial number. Example: M3 CFV, serial<br />

number 1245.<br />

6. RDS/EFC COMPUTATIONS. Enter all rounds that have an EFC of 1.0.<br />

7. CANNON SERIAL NUMBER. Enter serial number of receiver.<br />

8. RETUBINGS. Note this block is used for accountability of firing pins as replacement occurs. If the initial pin is in the gun, place a zero<br />

in this block. Upon first pin replacement, the zero is changed to a 1 and so on. When a pin is replaced, a note is placed in column 10i<br />

(remarks) to include date pin was changed and total rounds on weapon at the time of pin replacement. <strong>The</strong> remaining life column, 10h<br />

lower portion, has 8,000 or 12,000 placed in it at time of pin replacement to reflect the remaining life of the new pin.<br />

Figure 5–4. Sample DA Form 2408–4 used for a 25mm automatic gun<br />

DA PAM 750–8 22 August 2005<br />