Poster<br />

Topic: General Orthopaedics<br />

Abstract number: 25025<br />

EVALUATION OF A NEW FIBRE OPTIC TECHNIQUE FOR RECORDING OF<br />

INTRAMUSCULAR PRESSURE (IMP)<br />

Jorma STYF, Andreas NILSSON, Qiuxia ZHANG<br />

Department of Orthopaedics, University of <strong>Gothenburg</strong>, Sahlgrenska University<br />

Hospital, <strong>Gothenburg</strong> (SWEDEN)<br />

We have evaluated the performance of a new fibre optic catheter to measure IMP in<br />

a human model of simulated leg compartment syndrome. IMP in the anterior tibial<br />

muscle was measured simultaneously by a fibre optic technique (Samba Sensor) and<br />

a needle-injection technique (Stryker) in 12 legs of 7 healthy subjects (age 23-37<br />

years). Through a Venflon tube (1.3 mm) an optic transducertipped fibre (diameter<br />

0.42 mm) was inserted 20 mm lateral to tibial tuberosity. The Stryker needle (1.3×64<br />

mm) was inserted 10 mm lateral or medial to the optic fibre into the same depth,<br />

verified by sonography. Abnormally elevated IMP was induced by venous obstruction<br />

of a casted leg. IMP at baseline was 4.7±1.8/6.6±2.5 mmHg (p