4-Haptic MICS<br />
4-Haptic<br />
3-Haptic<br />
Table 1: IOL-Injector <strong>Correlation</strong> Matrix<br />
IOL Diopter Range & Injector / Cartridge<br />
CT SPHERIS ® 209M<br />
0.0 to +32.0 D<br />
AT.Shooter A2-2000 / ACM2<br />
or<br />
AT.Shooter A1-2000 / VISCOJECT 1.8 Cartridge Set 1<br />
or<br />
VISCOJECT 1.8 Injector Set 1<br />
or<br />
Single Use Injector A6 / *AT.Smart Cartridge Set 2<br />
CT ASPHINA ® 409M<br />
CT ASPHINA ® 509M<br />
AT LISA ® 809M<br />
AT TORBI ® 709M -10.0 to +24.0 D sphere with +1.0 to +4.0 D cylinder<br />
Same injectors and cartridges as above<br />
AT LISA<br />
+24.5 to +32.0 D sphere or +4.5 to +12.0 D cylinder<br />
ACCUJECT 2.6<br />
® toric 909M<br />
BLUEMIXS ® Pre-Loaded IOLs<br />
CT ASPHINA ® 409MP<br />
CT ASPHINA ® 509MP<br />
AT LISA ® 809MP<br />
AT LISA ® tri 839MP<br />
AT TORBI ® 709MP<br />
AT LISA ® toric 909MP<br />
CT SPHERIS ® 204<br />
CT ASPHINA ® 404<br />
SkyJet® Pre-Loaded IOL<br />
CT ASPHINA ® 604P<br />
Bigbag ®<br />
SkyJet ® Pre-Loaded IOLs<br />
CT SPHERIS ® 203P<br />
CT ASPHINA ® 603P<br />
0.0 to +32.0 D<br />
BLUEMIXS ® 180 3<br />
-10.0 to +24.0 D sphere with +1.0 to +4.0 D cylinder<br />
BLUEMIXS ® 180 3<br />
-10.0 to +30.0 D<br />
AT.Shooter A1-2000 / VISCOJECT 2.2 Cartridge Set 1<br />
or<br />
VISCOJECT 2.2 Injector Set 1<br />
+31.0 to +45.0 D (CT SPHERIS® 204)<br />
+31.0 to +42.0 D (CT ASPHINA® 404)<br />
AT.Shooter A1-2000 / OVALGLIDE Cartridge & Silicone Cushion LS604500<br />
or<br />
VISCOJECT Injector 4 / OVALGLIDE<br />
+14.0 to +30.0 D<br />
SkyInvent<br />
-10.0 to +13.0 D<br />
DK7784 / MACROGLIDE<br />
+8.0 to +26.0 D<br />
SkyJet ® 2.8<br />
+27.0 to + 30.0 D<br />
SkyJet ® 3.2<br />
+10.0 to +30.0 D<br />
SkyJet ® 2.8
1-Pc C-Loop<br />
3-Pc C-Loop<br />
Specialty<br />
CT 47S -10.0 to +30.0 D<br />
AT.Shooter A1-2000 / VISCOJECT 2.2 Cartridge Set 1<br />
or<br />
VISCOJECT 2.2 Injector Set 1<br />
CT 47LC<br />
CT 37A<br />
or<br />
AT LISA 801<br />
NAVIJECT 2.8-1P<br />
CT 53N<br />
AT LISA 802<br />
0.0 to +30.0 D<br />
OD650 DualTec Kit<br />
or<br />
NAVIJECT 2.8-3P<br />
+45.0 to +60.0 D<br />
AT.Shooter A1-2000 / VISCOJECT 2.2 Cartridge Set<br />
CT Xtreme D<br />
1<br />
or<br />
VISCOJECT 2.2 Injector Set 1<br />
or<br />
NAVIJECT 2.8-3P<br />
+18.0 to +26.0 D<br />
CT 59RET<br />
NAVIJECT 2.8-3P<br />
1<br />
VISCOJECT ‐ BIO or “classic” versions<br />
2<br />
*AT.Smart Cartridge Set also usable with AT‐Shooter A2‐2000<br />
3<br />
Also injectable with above‐mentioned systems (for non –MP) models when removed from BLUEMIXS® Loading Chamber<br />
4<br />
Any VISCOJECT injector with silicone cushion can be used with the OVALGLIDE Cartridge<br />
Table 2: Injector and Cartridge Type and Incision Size<br />
Injector Cartridge Injector Type Incision Size<br />
AT.Shooter A2-2000 ACM2 1<br />
Reusable<br />
AT.Shooter A1-2000 VISCOJECT 1.8 Cartridge set 1,2<br />
Reusable<br />
VISCOJECT 1.8 Injector Set 2 Disposable<br />
Single Use Injector A6 *AT.Smart Cartridge Set 1,4<br />
Disposable 2<br />
BLUEMIXS ® 180 Disposable, Pre-Loaded<br />
AT.Shooter A1-2000 VISCOJECT 2.2 Cartridge set 1,2<br />
Reusable<br />
VISCOJECT 2.2 Injector Set 2 Disposable<br />
ACCUJECT 2.6 Disposable<br />
SkyInvent Disposable, Pre-Loaded<br />
SkyJet ® 2.8 Disposable, Pre-Loaded<br />
NAVIJECT 2.8-1P Disposable<br />
NAVIJECT 2.8-3P Disposable<br />
OD 650 DualTec kit 3-P Acrylic 3.0 Disposable<br />
SkyJet ® 3.2 Disposable, Pre-Loaded<br />
AT.Shooter A1-2000<br />
OVALGLIDE Cartridge &<br />
Silicone Cushion LS604500<br />
Reusable<br />
VISCOJECT Injector 5 OVALGLIDE Cartridge 5 Disposable<br />
≥1.8mm [3]<br />
≥2.2mm<br />
≥2.8mm<br />
≥3.0mm<br />
≥3.2mm<br />
DK7784 MACROGLIDE Reusable ≥3.5mm<br />
1 Soft silicone cushion is included in the cartridge set<br />
2 VISCOJECT ‐ BIO or “classic” versions<br />
3 ACM2 and VISCOJECT 1.8 ≥ 1,5mm with docking technique<br />
4 *AT.Smart Cartridge Set also usable with AT‐Shooter A2‐2000<br />
5 VISCOJECT Injector from any VISCOJECT Injector Set. Must use the silicone cushion that comes pre‐installed on injector<br />
plunger.