Operator Control<br />

Daily control<br />

Carlow Precast Tanks<br />

Domestic Waste Water Treatment Plant<br />

Notes:<br />

• The AQUAstar tank is designed for maximum 1.0m overburden. Higher level <strong>of</strong> overburden<br />

must be consulted with structural engineer.<br />

• Garbage grinder in the kitchen may cause food wastes rotting in the tank which may<br />

cause bad smell from the tank.<br />

Recommendations:<br />

• Installation <strong>of</strong> standard <strong>inspection</strong> manhole at the CPT Zons AQUAstar tank inlet side.<br />

This will allow to easily remove any possible blockages from the inlet pipe.<br />

• Installation <strong>of</strong> domestic grease trap at the kitchen outlet pipe. According to EPA 2000<br />

Manual - Grease should not be allowed to enter the reactor. Major problem in the<br />

drainage system in dwelling houses is the build up <strong>of</strong> grease and waste solids in the<br />

drainage system. While the grease is still warm it flows freely but once it cools it solidifies<br />

and eventually blocks the pipes. The grease trap can be easily installed in new and existing<br />

waste water systems where 110mm piping is already being used.<br />

Soil polishing filters<br />

Soil polishing filters should be used to treat wastewater from mechanical aeration systems<br />

which AQUAstar is. These filters are employed to reduce micro-organisms, phosphorus, and<br />

nitrate nitrogen. Soil polishing filters may comprise in situ soil, improved soil or imported soil.<br />

There grass growth is allowed, there can be a large reduction in NO3-N. These soils should<br />

have percolation values (P or T) in the range <strong>of</strong> 1-50. Dosing may be by gravity or by pumped<br />

arrangements. Please contact us for soil polishing filter type and size recommendation (Mob.:<br />

086 1735964 or e-mail: aquastar@carlowprecasttanks.com).<br />

CPT Zons does not provide design and installation <strong>of</strong> soil polishing filters. CPT Zons may recommend<br />

trenches length or area according to EPA Manual. Client may ask County Council<br />

for established list <strong>of</strong> approved site assessors.<br />

Ensure that plant is in operation by checking the beacon installed<br />

above the tank. Green led confirms that plant is in operation,<br />

when green led is <strong>of</strong>f that means that there is no power<br />

supply. Red led on beacon indicates malfunction in operation<br />

and alarm message is displayed on the MULTICOM control unit.<br />

In this case contact Carlow Precast Tanks <strong>of</strong>fice for advice.<br />

Monthly controls<br />

<strong>For</strong> <strong>inspection</strong> <strong>purposes</strong> <strong>only</strong>.<br />

<strong>Consent</strong> <strong>of</strong> <strong>copyright</strong> <strong>owner</strong> <strong>required</strong> for any other use.<br />

Check if there is sludge in the plant's outflow and if inlet and outlet<br />

pipes are not blocked.<br />

When the end user is absent for a longer period, he must ensure<br />

that the operation controls are executed by another person.<br />

Sludge disposal<br />

The wastewater’s solid deposits (sludge) are retained in the<br />

plant’s primary settlement chamber. These solids must be disposed<br />

by an authorized waste management company.<br />

To guarantee optimum function <strong>of</strong> the plant, we recommend sludge removal <strong>only</strong> when <strong>required</strong>.<br />

Sludge removal must be performed when the primary settlement chamber’s sludge<br />

content exceeds 50 %. Ensure that <strong>only</strong> the primary settlement chambers are emptied, not<br />

the aeration tank. Otherwise, the bacteria which perform the biological treatment are lost<br />

and the plant must be reseeded.<br />

After de-sludging the primary settlement chamber must be refilled with clear or rain water.<br />

Refill from the middle chamber, so that possible remaining sludge is transferred into the first<br />

primary settlement chamber.<br />