Carlow Precast Tanks<br />

Domestic Waste Water Treatment Plant<br />

2 - 6 PE system 6 - 10 PE system<br />

Max designed population 6 PE 10 PE<br />

Tank size 1200 gallon (5.45m 3) 1500 gallon (6.82m 3)<br />

Tank weight 5.5 Tonnes 6.3 Tonnes<br />

Primary treatment chamber<br />

capacity<br />

2.10m 3 3.16m 3<br />

Aeration chamber capacity 2.00m 3 3.30m 3<br />

Designed flow rate 1080 litres/day 1800 litres/day<br />

Designed BOD load 0.36 kg BOD5/day 0.60 kg BOD5/day<br />

Installation on site<br />

The product is supplied to the end user as a ‘plug & play’ package<br />

to be installed by the CPT Zons AQUAstar operative. It is<br />

delivered on a platform-bodied truck with rear-mounted articulating<br />

crane and placed in its final position in the excavation by<br />

the driver.<br />

Client is to prepare:<br />

• Proper size excavation (please refer to the drawing on the<br />

following page) with level base free from projecting hard<br />

points such as rock or boulders<br />

• Approx. 100-200mm sand, gravel or broken stone layer at<br />

the base<br />

• The sides <strong>of</strong> the excavation should be so battered as to<br />

minimise risk <strong>of</strong> slippage or collapse.<br />

• Easy access to the lorry with articulating crane<br />

<strong>For</strong> <strong>inspection</strong> <strong>purposes</strong> <strong>only</strong>.<br />

<strong>Consent</strong> <strong>of</strong> <strong>copyright</strong> <strong>owner</strong> <strong>required</strong> for any other use.<br />

Pipe Connections:<br />

• Inlet: 100mm Ø µPVC pipe connection from the house to<br />

the tank.<br />

• Outlet: 32mm Ø reinforced hose from the connection at<br />

the tank to the distribution box at polishing filter<br />

Cable Connections:<br />

• 230V supply protected by a 20A RCBO and fed with a 3 x<br />

2.5mm 2 S.W.A cable. Leave sufficient cable to reach the<br />

tank to ensure connection is possible. Connection with AQ-<br />

UAstar unit must be made by customer’s electrician with<br />

IP65 rate (waterpro<strong>of</strong>) provided junction box.<br />

3<br />