28.01.2013 Views

For inspection purposes only. Consent of copyright owner required ...

For inspection purposes only. Consent of copyright owner required ...

For inspection purposes only. Consent of copyright owner required ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

S OURCE<br />

INFILTRATION<br />

CONTROL<br />

TRENCHES & SOAK-AWAYS<br />

Overflow Berm<br />

* Flood Studies Report, WRAP Classification<br />

SECTION<br />

Construction Cost<br />

PRIMARY CONSIDERATIONS<br />

Maintenance Requirements<br />

LOW<br />

HIGH<br />

Observational Well<br />

with Screw-Top Lid Run-<strong>of</strong>f filters through<br />

grass buffer strip<br />

Pea Gravel Filter Layer<br />

Protective Layer <strong>of</strong> Filter Fabric<br />

Trench:<br />

Filled with 30 - 60mm diameter<br />

clean stone / gravel<br />

Sand Filter<br />

(or Fabric Equivalent)<br />

BENEFITS<br />

�Water<br />

Quality Control YES<br />

�Water<br />

Quantity Control YES<br />

�Amenity<br />

Value NO<br />

L and Take<br />

LOW<br />

�Habitat<br />

Creation Value NO<br />

�Biological<br />

Treatment NO<br />

Side-entry pits drain to infiltration trench in car-park<br />

DESCRIPTION<br />

DESIGN<br />

n infiltration trench is a gravel /<br />

�The<br />

treatment volume should<br />

�Soils<br />

underlying the site should be<br />

rock-filled trench designed to<br />

completely infiltrate through the trench<br />

permeable, i.e. have a clay content <strong>of</strong><br />

Ainfiltrate run-<strong>of</strong>f to the ground.<br />

bottom in 24 hours.<br />

less than 20% and a silt/clay content <strong>of</strong><br />

Infiltration trenches are essentially long<br />

�Trenches<br />

should be under-drained, so<br />

less than 40%. (Refer BRE,1991 and<br />

thin soakaways (rock filled pits or large<br />

that in the event <strong>of</strong> clogging it can act as<br />

CIRIA, 1996). Infiltration controls can<br />

tanks structures). Run-<strong>of</strong>f is stored in<br />

an overflow.<br />

be used on soil types 1 or 2* and where<br />

the voids allowing it to slowly infiltrate it can be demonstrated that the trench �With<br />

long infiltration trenches it is<br />

through the bottom into the soil matrix. will infiltrate the design treatment advisable to provide <strong>inspection</strong> tubes at<br />

This reduces the volume <strong>of</strong> water that is volume within 12 hours under average regular intervals along the trench<br />

discharged into receiving watercourses winter rainfall (Campbell, 2000). (CIRIA, 2000).<br />

thereby reducing some <strong>of</strong> the impacts<br />

�A<br />

pre-treatment device such as a �The<br />

maximum contributing area to<br />

caused by excess flows and pollutants.<br />

swale or filter strip is recommended infiltration trenches should be less than<br />

upstream <strong>of</strong> the trench to reduce 5 hectares.<br />

incoming velocities and coarser �The<br />

infiltration device should not be<br />

sediments.<br />

constructed within 5m <strong>of</strong> the<br />

�The<br />

device should be constructed at foundations <strong>of</strong> buildings or under a<br />

least 1.5m above the maximum road.<br />

groundwater level or bedrock layer and �Do<br />

not construct near drinking water<br />

<strong>only</strong> where the groundwater wells, septic tanks or drainfields .<br />

classification allows.<br />

�During<br />

construction, measures to<br />

�The<br />

trench should be filled with clean minimise sediment erosion and soil<br />

stones that can retain the <strong>required</strong> compaction should be used.<br />

volume <strong>of</strong> water to be treated in their<br />

�The<br />

facility should not come into use<br />

void space.<br />

until construction and landscaping <strong>of</strong><br />

�The<br />

stone should be wrapped in a<br />

the site that drains to it is completed.<br />

geo-textile. This fabric should be<br />

�Areas<br />

upstream <strong>of</strong> the trench should<br />

selected on the basis <strong>of</strong> durability with<br />

be stabilised.<br />

adequate opening size to resist<br />

clogging.<br />

<strong>For</strong> <strong>inspection</strong> <strong>purposes</strong> <strong>only</strong>.<br />

<strong>Consent</strong> <strong>of</strong> <strong>copyright</strong> <strong>owner</strong> <strong>required</strong> for any other use.<br />

Run-<strong>of</strong>f exfiltrates through<br />

undisturbed sub-soils with a<br />

minimum rate <strong>of</strong> 1.27 cm per hour<br />

MORE OVERLEAF - 1 <strong>of</strong> 2<br />

GREATER DUBLIN STRATEGIC DRAINAGE STUDY - ENVIRONMENTAL MANAGEMENT POLICY<br />

EPA Export 24-08-2012:23:55:53

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!