Note: In case the transformer are exported without the M.S. Tank and Transformer Oil, then the input<br />

item No. 3 i.e. Transformer Oil or Transformer Oil Base Stock, shall not be permitted<br />

C329 Transformers (Copper<br />

Wound) above 1600 KVA<br />

upto & including 4000<br />

KVA, 3 Phase, Oil Cooled<br />

1 No. 1 CRGO Steel/ Sheet/ Coil<br />

OR<br />

CRGO Transformers Lamination<br />

C58<br />

1.45 kgs/KVA<br />

2 Copper winding wires/ strips/<br />

wire bars/ wire rods/ cathodes<br />

Net to net<br />

0.92 kg/KVA<br />

3 Transformer Oil<br />

OR<br />

0.89 kgs/KVA<br />

3 Transformer Oil Base Stock 0.99 kgs/KVA.<br />

4 Pre-compressed press board 0.23 kgs/KVA<br />

5 Phenolic Resin bonded paper 0.02 kgs/KVA<br />

6 Motorised off-load/ on-load tap<br />

changer/ Switch<br />

1 No. (Net to net)<br />

7 Pre-pressed boards/ moulded<br />

components<br />

1 No. (Net to net)<br />

Note. In case the transformer are exported without the M.S. Tank and Transformer Oil, then the input<br />

item No. 3 i.e. Transformer Oil or Transformer Oil Base Stock, shall not be permitted.<br />

C330 Transformers (Copper<br />

Wound) above 25000<br />

KVA upto & including<br />

63000 KVA, 3 Phase, Oil<br />

Cooled<br />

1 No. 1 CRGO Steel/ Sheet/ Coil<br />

OR<br />

0.84 kgs/KVA<br />

CRGO Transformers Lamination Net to net<br />

2 Copper winding wires/ strips/<br />

wire bars/ wire rods/ cathodes<br />

0.39 kg/KVA<br />

3 Transformer Oil<br />

OR<br />

0.79 kgs/KVA<br />

3 Transformer Oil Base Stock 0.87 kgs/KVA<br />

4 Pre-compressed press board 0.08 kgs/KVA<br />

5 Phenolic Resin bonded paper 0.02 kgs/KVA<br />

6 Motorised off-load/ on-load tap<br />

changer/ Switch<br />

1 No. (Net to net)<br />

7 Pre-pressed boards/ moulded<br />

components<br />

1 No. (Net to net)<br />

Note: In case the transformer are exported without the M.S. Tank and Transformer Oil, then the input<br />

item No. 3 i.e. Tranformer Oil or Transformer Oil Base Stock, shall not be permitted.<br />

C331 Transformers (Copper<br />

Wound) above 400 KVA<br />

upto & including 1600<br />

KVA, 3 Phase, Oil Cooled<br />

1 No. 1 CRGO Steel/ Sheet/ Coil<br />

OR<br />

CRGO Transformers Lamination<br />

1.71 kgs/KVA<br />

2 Copper Winding Wires/ strips/<br />

wire bars/ wire rods/cathodes<br />

Net to net<br />

1.22 kg/KVA<br />

3 Transformer Oil<br />

OR<br />

1.31 kgs/KVA<br />

3 Transformer Oil Base Stock 1.44 kgs/KVA.<br />

4 Pre-compressed press board 0.26 kgs/KVA<br />

5 Phenolic Resin bonded paper 0.03 kgs/KVA<br />

6 Motorised off-load/ on-load tap<br />

changer/ Switch<br />

1 No. (Net to net)<br />

7 Pre-pressed boards/ moulded<br />

components<br />

1 No. (Net to net)<br />

Note: In case the transformer are exported without the M.S. Tank and Transformer Oil, then the input<br />

item No. 3 i.e. Transformer Oil or Transformer Oil Base Stock, shall not be permitted<br />

C332 Transformers (Copper<br />

Wound) above 4000 KVA<br />

1 No. 1 CRGO Steel/ Sheet/ Coil<br />

OR<br />

CRGO Transformers Lamination<br />

1.12 kgs/KVA<br />

Net to net