7 Pre-pressed boards/ moulded<br />

components<br />

C57<br />

1 No. (Net to net)<br />

Note 1. In case the transformer are exported without the M.S. Tank and Transformer Oil, then the input<br />

item No. 3 i.e. Transformer Oil or Transformer Oil Base Stock, shall not be permitted.Note 2. If in the<br />

export product, the core is of amorphous electrical steel, then import of 2.6 kg/KVA of "amorphus<br />

electrical steel sheet/ coil may be allowed in place of import item No. 1 i.e. CRGO Steel laminations/<br />

Sheets/ Coil allowed in this norm<br />

C326 Transformers (Copper<br />

Wound) above 100 KVA<br />

upto & including 400<br />

KVA, 3 Phase, Oil Cooled<br />

1 No. 1 CRGO Steel/ Sheet/ Coil<br />

OR<br />

CRGO Transformers Lamination<br />

2.11 kgs/KVA<br />

2 Copper Winding Wires/ strips/<br />

wire bars/ wire rods/cathodes<br />

Net to net<br />

1.53 kg/KVA<br />

3 Transformer Oil<br />

OR<br />

2.31 kgs/KVA<br />

3 Transformer Oil Base Stock 2.54 kgs/KVA<br />

4 Pre-compressed press board 0.26 kgs/KVA<br />

5 Phenolic Resin bonded paper 0.05 kgs/KVA<br />

6 Motorised off-load/ on-load tap<br />

changer/ Switch<br />

1 No. (Net to net)<br />

7 Pre-pressed boards/ moulded<br />

components<br />

1 No. (Net to net)<br />

Note: In case the tranformer are exported without the M.S. Tank and Transformer Oil, then the input<br />

item No. 3 i.e. Transformer Oil or Transformer Oil Base Stock, shall not be permitted<br />

C327 Transformers (Copper<br />

Wound) above 10000<br />

KVA upto & including<br />

25000 KVA, 3 Phase, Oil<br />

Cooled<br />

1 No. 1 CRGO Steel/ Sheet/ Coil<br />

OR<br />

0.99 kgs/KVA<br />

CRGO Transformers Lamination Net to net<br />

2 Copper winding wires/ strips/<br />

wire bars/ wire rods/ cathodes<br />

0.51 kg/KVA<br />

3 Transformer Oil<br />

OR<br />

0.86 kgs/KVA<br />

3 Transformer Oil Base Stock 0.95 kgs/KVA.<br />

4 Pre-compressed press board 0.11 kgs/KVA<br />

5 Phenolic Resin bonded paper 0.02 kgs/KVA<br />

6 Motorised off-load/ on-load tap<br />

changer/ Switch<br />

1 No. (Net to net)<br />

7 Pre-pressed boards/ moulded<br />

components<br />

1 No. (Net to net)<br />

Note: In case the transformer are exported without the M.S. Tank and Transformer Oil, then the input<br />

item No. 3 i.e. Transformer Oil or Transfor Oil Base Stock, shall not be permitted<br />

C328 Transformers (Copper<br />

Wound) above 100000<br />

KVA , 3 Phase, Oil<br />

Cooled<br />

1 No. 1 CRGO Steel/ Sheet/ Coil<br />

OR<br />

0.61 kgs/KVA<br />

CRGO Transformers Lamination Net to net<br />

2 Copper winding wires/ strips/<br />

wire bars/ wire rods/ cathodes<br />

0.23 kg/KVA<br />

3 Transformer Oil<br />

OR<br />

0.42 kgs/KVA<br />

3 Transformer Oil Base Stock 0.46 kgs/KVA.<br />

4 Pre-compressed press board 0.05 kgs/KVA<br />

5 Phenolic Resin bonded paper 0.01 kgs/KVA<br />

6 Motorised off-load/ on-load tap<br />

changer/ Switch<br />

7 Pre-pressed boards/ moulded<br />

components<br />

1 No. (Net to net)<br />

1 No. (Net to net)