SECTION 5 - TECHNICAL DATA<br />

TABLE 4 - PHYSICAL DATA<br />

The data shown in this table is applicable to selected<br />

typical configurations. Other configurations are available<br />

through our configuration/selection software.<br />

50<br />

FORM 201.28-NM1.1<br />

ISSUE DATE: 8/29/2012<br />

UNIT FRAME 015 016 017 018 019 019<br />

CONDENSER CODE 3 5 8 3 5 8<br />

EVAPORATOR CODE B B C A A B<br />

GENERAL UNIT DATA<br />

Number of Independent Refrigerant Circuits 2<br />

Refrigerant Charge, R-134a,<br />

Ckt.-1/Ckt.-2, lbs (kg)<br />

Oil Charge, Ckt.-1/Ckt.-2, gal (liters)<br />

175/175<br />

(80/80)<br />

2.1/2.0<br />

(8.0/7.7)<br />

190/190<br />

(86/86)<br />

2.2/2.2<br />

(8.5/8.5)<br />

225/225<br />

(102/102)<br />

2.5/2.5<br />

(9.3/9.3)<br />

% Minimum Load 10%<br />

Unit shipping weight, lbs (kg) 1<br />

Operating Weight, lbs (kg) 1<br />

Chassis Dimensions - Length, Ft (mm)<br />

Chassis Dimensions - Width, Ft (mm)<br />

Chassis Dimensions - Height, Ft (mm)<br />

COMPRESSORS, SEMI-HERMETIC SCREW<br />

11518<br />

(5224)<br />

11979<br />

(5434)<br />

203.3<br />

(5163)<br />

88.3<br />

(2242)<br />

94.6<br />

(2403)<br />

12084<br />

(5481)<br />

12546<br />

(5691)<br />

247.2<br />

(6280)<br />

88.3<br />

(2242)<br />

94.6<br />

(2403)<br />

14668<br />

(6653)<br />

15432<br />

(7000)<br />

291.2<br />

(7397)<br />

88.3<br />

(2242)<br />

94.6<br />

(2403)<br />

Qty per Chiller 2<br />

CONDENSER FANS<br />

175/155<br />

(80/70)<br />

2.4/2.0<br />

(9.2/7.7)<br />

12019<br />

(5452)<br />

12460<br />

(5652)<br />

247.0<br />

(6274)<br />

88.3<br />

(2242)<br />

94.6<br />

(2403)<br />

190/170<br />

(86/78)<br />

2.6/2.1<br />

(9.7/8.0)<br />

12781<br />

(5797)<br />

13222<br />

(5997)<br />

291.2<br />

(7397)<br />

88.3<br />

(2242)<br />

94.6<br />

(2403)<br />

220/195<br />

(100/89)<br />

2.7/2.2<br />

(10.4/8.5)<br />

Number Ckt-1/Ckt-2 4/4 5/5 6/6 6/4 7/5 8/6<br />

<strong>Air</strong> on Condenser (Min/Max), °F (°C ) 0/125 (4.4/15.6)<br />

EVAPORATOR, SHELL AND TUBE HYBRID FALLING FILM 2<br />

13776<br />

(6248<br />

14237<br />

(6458)<br />

335.2<br />

(8514)<br />

88.3<br />

(2242)<br />

94.6<br />

(2403)<br />

Water Volume, gal (liters) 58 (220) 58 (220) 71 (269) 48 (182) 48 (182) 58 (220)<br />

Leaving Water Temperature<br />

(Min/Max), °F (°C ) 3<br />

Maximum Water Side Pressure,<br />

psig (bar)<br />

Maximum Refrigerant Side<br />

Pressure, psig (bar)<br />

40/60 (4.4/15.6)<br />

150 (10.3)<br />

235 (16.2)<br />

Evap Drain Connection, in 3/4<br />

NOTES:<br />

1. Shipping and operating weights shown are for base unit; selected options may add weight to unit. Contact your nearest <strong>Johnson</strong> <strong>Controls</strong><br />

Sales office for weight data.<br />

2. The evaporator is protected against freezing to 0°F(-17.8°C) with a standard heater.<br />

Please contact your nearest <strong>Johnson</strong> <strong>Controls</strong> Sales Office<br />

for the chiller configuration that best matches your<br />

specific needs.<br />

3. For leaving liquid temperature below 40°F(4.4°C) or above 60°F (15.6°C), contact your nearest <strong>Johnson</strong> <strong>Controls</strong> Sales Office for application<br />