SECTION 4 - INSTALLATION<br />
FIGURE 5 - ACCEPTABLE MINIMUM CLEARANCES<br />
AROUND/BETWEEN UNIT(S)<br />
24<br />
1.8 m (6')<br />
Minimum<br />
Tube Removal<br />
Clearance Area<br />
1.2 m (4')<br />
Minimum<br />
3 m (10')<br />
Minimum<br />
Control Panel<br />
Tube Removal<br />
Clearance Area<br />
TABLE 1 - MINIMUM EVAPORATOR TUBE REMOV-<br />
AL CLEARANCE<br />
TUBE REMOVAL<br />
MODEL <strong>YVAA</strong> CLEARANCE DIMENSIONS<br />
A B C<br />
FRAME EVAP COND IN. MM IN. MM IN. MM<br />
015 3 B 26 663 36 914 132 3353<br />
016 5 B 26 663 36 914 132 3353<br />
017 8 C 26 663 36 914 156 3962<br />
018 3 A 26 663 36 914 144 3658<br />
019 5 A 26 663 36 914 144 3658<br />
019 8 B 26 663 36 914 132 3353<br />
020 0 C 26 663 36 914 156 3962<br />
021 3 A 26 663 36 914 144 3658<br />
021 5 C 26 663 36 914 156 3962<br />
021 8 C 26 663 36 914 156 3962<br />
023 3 B 26 663 36 914 132 3353<br />
024 5 C 26 663 36 914 156 3962<br />
024 8 C 26 663 36 914 156 3962<br />
026 3 B 26 663 36 914 132 3353<br />
027 3 D 26 663 36 914 192 4877<br />
027 5 E 26 663 36 914 192 4877<br />
027 8 E 26 663 36 914 192 4877<br />
029 5 E 26 663 36 914 192 4877<br />
030 3 C 26 663 36 914 156 3962<br />
030 5 C 26 663 36 914 156 3962<br />
030 8 E 26 663 36 914 192 4877<br />
031 8 E 26 663 36 914 192 4877<br />
032 3 E 26 663 36 914 192 4877<br />
033 3 C 26 663 36 914 156 3962<br />
034 3 E 26 663 36 914 192 4877<br />
034 5 E 26 663 36 914 192 4877<br />
050 0 J 26 663 36 914 192 4877<br />
052 3 J 26 663 36 914 192 4877<br />
FORM 201.28-NM1.1<br />
ISSUE DATE: 8/29/2012<br />
Clearance dimensions provided in Figure<br />
5 are necessary to maintain good airflow<br />
and ensure correct unit operation. It is<br />
also necessary to consider access requirements<br />
for safe operation and maintenance<br />
of the unit and power and control<br />
panels. Local health and safety regulations,<br />
or practical considerations for<br />
service replacement of large components,<br />
may require larger clearances than those<br />
recommended.<br />
VIBRATION ISOLATORS<br />
Optional sets of vibration isolators can be supplied<br />
loose with each unit.<br />
Using the Isolator tables shipped with the unit in the<br />
information pack. Identify each mount and its correct<br />
location on the unit.<br />
Installation<br />
Place each mount in its correct position and lower the<br />
unit carefully onto the mounts ensuring the mount engages<br />
in the mounting holes in the unit base frame.<br />
On adjustable mounts, transfer the unit weight evenly<br />
to the springs by turning the mount adjusting nuts (located<br />
just below the top plate of the mount) counterclockwise<br />
to raise and clockwise to lower. This should<br />
be done two turns at a time until the top plates of all<br />
mounts are between 1/4" (6 mm) and 1/2" (12 mm)<br />
clear of top of their housing and the unit base is level.<br />
SHIPPING BRACES<br />
The chiller’s modular design does not require shipping<br />
braces.<br />
CHILLED LIQUID PIPING<br />
General Requirements<br />
The following piping recommendations are intended to<br />
ensure satisfactory operation of the unit(s). Failure to<br />
follow these recommendations could cause damage to<br />
the unit, or loss of performance, and may invalidate the<br />
warranty.<br />
The maximum flow rate and pressure<br />
drop for the evaporator must not be exceeded<br />
at any time. Refer to SECTION 5<br />
- TECHNICAL DATA on Page 49 for<br />
details.<br />