SMA Solar Technology AG Electrical Connection<br />

For connection, proceed as follows:<br />

NOTICE!<br />

Electrostatic discharges can damage the communication interface.<br />

Internal components of the <strong>Sun</strong>ny Island can be irreparably damaged by static discharge.<br />

• Ground yourself before touching a component.<br />

1. Remove the right plug of the two plugs in the rubber connection area.<br />

2. Feed the cable from the outside through the cable conduit (D) into the <strong>Sun</strong>ny Island.<br />

3. Plug the cable into the "ComSmaIn" socket.<br />

4. Place the plug around the cable.<br />

5. Insert the plug in its designated opening in the rubber connection area.<br />

6. Lay the cable in area (C).<br />

7. Connect the cable. Assignment pins in the RJ45 socket:<br />

PV inverter / wind<br />

power inverter /<br />

<strong>Sun</strong>ny WebBox<br />

RS485 - signal<br />

assignment<br />

RJ45 socket - <strong>Sun</strong>ny<br />

Island<br />

RJ45 color coding<br />

2 A (Data+) 3 White and green<br />

5 GND 2 Orange<br />

7 B (Data–) 6 Green<br />

8. The RS485 data bus of the <strong>Sun</strong>ny Island is terminated with a terminating resistor.<br />

This terminating resistor is already plugged into the "ComSmaOut" socket. Only remove the plug<br />

if you want to connect another communication device.<br />

9. Plug the communication interface onto the board (A).<br />

<strong>Technical</strong> <strong>Description</strong> SI<strong>5048</strong>-TB-TEN110340 51