SMA Solar Technology AG Troubleshooting<br />

20.7 Failure Categories<br />

The <strong>Sun</strong>ny Island distinguishes between 5 different levels of failures, each requiring different user<br />

interaction.<br />

Level <strong>Description</strong> Display on<br />

the<br />

<strong>Sun</strong>ny Island<br />

Meaning<br />

1 Warning Warning Warning, device continues to run. There is an explicit<br />

information on the Home Screen that a warning was<br />

recorded.<br />

2 Malfunction 1 Malfunction Failure that can only be detected during operation.<br />

Device switches off. Device can be restarted<br />

immediately (autostart).<br />

3 Malfunction 2 Malfunction Failure that can also be detected in standby mode.<br />

Device switches off. The device can only be restarted<br />

(autostart) once the system detects that the failure has<br />

ended.<br />

4 Failure Failure Device fault. Device switches off. User interaction<br />

required (failure removal, confirmation, manual<br />

restart).<br />

5 Device defect Defect Device is defect. Device switches off and does not<br />

switch on again. Permanent disable. Device must be<br />

replaced.<br />

<strong>Technical</strong> <strong>Description</strong> SI<strong>5048</strong>-TB-TEN110340 201