Troubleshooting SMA Solar Technology AG<br />

20.5 Display of Failures and Events<br />

Each failure and each event have a unique three-digit display number that is created according to the<br />

parameter/measuring value assignment. The events and failures have the identical numerical range:<br />

• 1xx - INV - Inverter<br />

• 2xx - BAT - Battery<br />

• 3xx - EXT - Extern<br />

• 4xx - GEN = Generator<br />

• 5xx - GRD - Grid<br />

• 6xx - RLY - Relay<br />

• 7xx - SYS - System<br />

• 8xx - AUX - External devices and components<br />

Meaning of the abbreviations<br />

"F" marks a failure, "W" marks a warning and "E" marks an event.<br />

In the event of a failure, and provided it is recorded, "!" is displayed for a failure that has<br />

occurred and "C" is displayed for a failure that has stopped.<br />