Parameter lists SMA Solar Technology AG 315# Inverter Slave3 Diagnosis Number Name Description Value Explanation 01 FwVerSlv3 Firmware version of the Sunny Island slave 3 02 SNSlv3 Serial number of the Sunny Island slave 3 03 OnTmhSlv3 Operating hours of the Sunny Island slave 3 in hours 04 PhSlv3 Phase of the Sunny Island slave 3 L1 Phase L1 L2 Phase L2 L3 Phase L3 05 OpSttSlv3 Operating state of the Sunny Island slave 3 06 FwVer2Slv3 Firmware version of the Sunny Island slave 3 07 FwVer3Slv3 BFR boot loader of the Sunny Island slave 3 08 FwVer4Slv3 DSP boot loader of the Sunny Island slave 3 Operating Operation Warning Warning Failure Error 186 SI5048-TB-TEN110340 Technical Description

SMA Solar Technology AG Parameter lists 19.3.2 Battery Diagnosis (320#) Number Name Description Value Explanation Default Value 01 Soh State of Health (SOH) Ratio of current capacity to its nominal value 100 % 02 StatTm Statistics metering run time in days 03 ChrgFact Charging factor 1.00 04 BatEgyCntIn Energy meter for battery charge in kWh 05 BatEgyCntOut Energy meter for battery discharge in kWh 06 AhCntIn Meter for battery charging ampere hours 07 AhCntOut Meter for battery discharging ampere hours 08 BatTmpPkMin Minimum battery temperature in °C 09 BatTmpPkMax Maximum battery temperature in °C 10 EquChrgCnt Equalization charge meter 11 FulChrgCnt Full charge meter 12 BatCurOfsErr Offset error of battery current in A 13 OcvPointCnt Meter for open-circuit voltage points 15 AhCntFul Meter for battery discharging ampere hours since the last full charge (in Ah/100 Ah) 16 AhCntEqu Meter for battery discharging ampere hours since the last equalization charge (in Ah/100 Ah) 17 BatVtgPk Maximum battery voltage to have arisen in V 18 BatCurPkIn Maximum battery current in the charging direction (in A) Technical Description SI5048-TB-TEN110340 187

Parameter lists SMA Solar Technology AG<br />

315# Inverter Slave3 Diagnosis<br />

Number Name <strong>Description</strong> Value Explanation<br />

01 FwVerSlv3 Firmware version of the<br />

<strong>Sun</strong>ny Island slave 3<br />

02 SNSlv3 Serial number of the<br />

<strong>Sun</strong>ny Island slave 3<br />

03 OnTmhSlv3 Operating hours of the<br />

<strong>Sun</strong>ny Island slave 3 in hours<br />

04 PhSlv3 Phase of the <strong>Sun</strong>ny Island slave 3 L1 Phase L1<br />

L2 Phase L2<br />

L3 Phase L3<br />

05 OpSttSlv3 Operating state of the<br />

<strong>Sun</strong>ny Island slave 3<br />

06 FwVer2Slv3 Firmware version of the<br />

<strong>Sun</strong>ny Island slave 3<br />

07 FwVer3Slv3 BFR boot loader of the<br />

<strong>Sun</strong>ny Island slave 3<br />

08 FwVer4Slv3 DSP boot loader of the<br />

<strong>Sun</strong>ny Island slave 3<br />

Operating Operation<br />

Warning Warning<br />

Failure Error<br />

186 SI<strong>5048</strong>-TB-TEN110340 <strong>Technical</strong> <strong>Description</strong>