SMA Solar Technology AG Multicluster Operation<br />

16.2 Initial Start-up of the Multicluster System<br />

1. Carry out steps 1 - 3 in section 8.2 ”Starting the Quick Configuration Guide (QCG)”<br />

(page 57).<br />

2. At "New System" set the following parameters:<br />

– Device type (master, slave 1, slave 2, slave 3)<br />

– Voltage/frequency type (230V_50Hz, 220V_60Hz), default setting: "230V_50Hz"<br />

– System configuration (3Phase, 1Phase 1, 1Phase 2, 1Phase 3, 1Phase 4, MC-Box),<br />

for Multicluster operation choose "MC-Box". Default setting: "1Phase 1"<br />

– Multicluster configuration (MainCluster, ExtensionClst1, ExtensionClst2, ExtensionClst3,<br />

ExtensionClstN), default setting is "MainCluster"<br />

– Box type choice (MC-Box-6, MC-Box-9, MC-Box-12), preset: "MC-Box-6"<br />

3. For the other settings proceed as described in section 8.2 ”Starting the Quick Configuration<br />

Guide (QCG)” (page 57) under point 3.<br />