SMA Solar Technology AG The <strong>Sun</strong>ny Island <strong>5048</strong><br />
2 The <strong>Sun</strong>ny Island <strong>5048</strong><br />
2.1 Properties<br />
The <strong>Sun</strong>ny Island <strong>5048</strong> is a bidirectional inverter (battery inverter and charger) for stand-alone<br />
systems. The <strong>Sun</strong>ny Island supplies consumers on the stand-alone grid side and charges battery banks<br />
with the energy from grid-feeding units connected on the AC side.<br />
The comfortable support of AC and DC coupling, as well as the expandability of the systems formed<br />
with the <strong>Sun</strong>ny Island guarantee highest flexibility. In addition, innovative technology allows the<br />
<strong>Sun</strong>ny Island to achieve a maximum efficiency of more than 95 %. Optimized for partial load<br />
operation, it impresses with low open-circuit and standby consumption. Due to the high overload<br />
capabilities and the integrated output management, there is no need to oversize the <strong>Sun</strong>ny Island.<br />
The parallel operation of up to 3 devices on a single phase system or 3 devices on a three-phase<br />
system enables the <strong>Sun</strong>ny Island to be used to set up stand-alone grid supply systems with output<br />
power of 3 kW … 26 kW and up to 300 kW in Multicluster systems. Thanks to its sophisticated<br />
generator management, it can control connected diesel generators in a particularly gentle and fuelsaving<br />
manner. The power distribution grid can also be integrated. The <strong>Sun</strong>ny Island can also<br />
deactivate loads automatically if the battery does not provide sufficient electrical energy.<br />
The stand-alone grid's critical component, the battery, is monitored diligently and optimally utilized.<br />
The intelligent battery management precisely records the battery's state of charge. This makes<br />
possible an improved utilization of the battery capacity, which also means that smaller and thus more<br />
cost-effective batteries can be used without affecting performance.<br />
In order to prevent premature aging caused by incorrect charging and frequent deep discharge, the<br />
<strong>Sun</strong>ny Island has an intelligent charge control and reliable deep discharge protection. Thanks to these<br />
functions, the battery life can be greatly extended in comparison with simpler devices.<br />
Despite its complex functioning, the <strong>Sun</strong>ny Island is easy to configure. All the settings required for<br />
operation can be quickly and easily programmed in a few steps using the "Quick Configuration<br />
Guide". By employing the concept of central operation referred to as "Single Point of Operation", the<br />
system/cluster parameters are only set on the master device, and all other devices adopt the<br />
configuration automatically. The easy-to-understand menu navigation allows quick access to all<br />
important data, even while the system is running. An SD card provides uncomplicated system control,<br />
and thus facilitates any service work.<br />
Saving Data and Events<br />
Always use the SD card to save data and events. This way, in case of a failure, SMA Solar<br />
Technology can help you quickly.<br />
The <strong>Sun</strong>ny Island monitors the set voltage and frequency limits on the grid and generator. If these limits<br />
are not observed, it disconnects from the external source with virtually no interruption and changes to<br />
stand-alone grid operation. The <strong>Sun</strong>ny Island <strong>5048</strong> also has an integrated anti-islanding feature. This<br />
is a protective procedure for preventing unintended islanding on the generator and/or external<br />
power supply line point.<br />