<strong>Task</strong> <strong>Targeted</strong> <strong>Automation</strong>, TTA<br />

RSD Pro and RSA Pro<br />

<strong>The</strong> superior sorting and/or aliquoting solution<br />

for your laboratory<br />

RSD Pro RSA Pro


Enhance Your Lab<br />

<strong>Roche</strong>’s state-of-the-art automation allows<br />

small to large laboratories to realize customized<br />

sample handling solutions for improved<br />

workflow.<br />

For medium to very large laboratories, <strong>Task</strong><br />

<strong>Targeted</strong> <strong>Automation</strong> from <strong>Roche</strong> supports a<br />

high level of automation specific to the needs of<br />

your the laboratory, for example<br />

• Multiple tube types<br />

• Wide variety of sample carriers<br />

• Advanced camera system for tube identification<br />

• Selective decapping and recapping of tubes<br />

• Archiving of tubes.<br />

Fully scalable and extendable, <strong>Task</strong> <strong>Targeted</strong><br />

<strong>Automation</strong> can improve the efficiency of<br />

pre-analytical processing steps, while helping to<br />

reduce the operator’s exposure to potentially<br />

hazardous biological material and helps to eliminate<br />

repetitive stress injuries.<br />

*On-line centrifuge module is not yet available<br />

<strong>The</strong> Basic Systems<br />

Overview<br />

<strong>The</strong> RSD Pro and RSA Pro basic system delivers the following<br />

functions:<br />

• Administration of test requests downloaded from the<br />

laboratory IT system<br />

• Detection of tube type of each primary tube<br />

• Bi-directional host interface for data exchange<br />

• Distribution/sorting of primary tubes<br />

• Distribution/sorting of aliquot tubes (RSA Pro only)<br />

• Creation of one or more aliquot tubes (RSA Pro only)<br />

• Bar code labeling of the aliquot tubes (RSA Pro only)<br />

<strong>The</strong> RSD Pro and RSA Pro can be extended with the following<br />

options:<br />

• Recap unit (selective for primary/secondary)<br />

• Camera system<br />

• Online connected centrifuge*<br />

RSD Pro and RSA Pro Basic System<br />

Option: Recap Unit<br />

• for primary tubes<br />

or<br />

• for secondary tubes<br />

Option: Camera Extension<br />

• for tube type identification<br />

or<br />

• for tube type identification and sample<br />

volume recognition<br />

Option: On-line Centrifuge<br />

• Single or double centrifuge*


System Overview<br />

(RSA Pro only)<br />

Total Workflow Solutions from <strong>Roche</strong><br />

<strong>Roche</strong> offers powerful platforms and different levels of<br />

automation. Together with <strong>Roche</strong> Middleware complete<br />

workflow efficiency can be realized from order entry to<br />

sample archive.<br />

<strong>The</strong> primary benefits include:<br />

• Powerful sample flow management functions using a<br />

rule-based decision process from sample arrival to sample<br />

archive, sample tracking, and rerun/repeat/reflex test<br />

handling<br />

• <strong>The</strong> reduction of repetitive, error-prone and bio-hazardous<br />

pre- and post-analytical work steps<br />

• Extendable, flexible and scalable platforms. <strong>The</strong> <strong>Roche</strong><br />

process solutions are highly configurable and can be adapted<br />

to most customer requirements – including third party tubes<br />

and racks.<br />

Our Laboratory Process Analysis can determine the best<br />

solution for your lab. Specific needs may vary from the example<br />

listed.<br />

• Multiple workflow cycles to adapt to customer workloads


Functions and Features<br />

Input Area<br />

Tubes can be put into the input area in any order. Presorting<br />

according to tube diameter, tube height, cap color, open/closed<br />

is not required.<br />

<strong>The</strong> primary features of the input area are:<br />

• Large sample capacity for up to 600 tubes<br />

• Parallel processing of most of the established hematology,<br />

coagulation, serum, plasma and urine tubes<br />

• Continuous loading of sample tubes during routine operation<br />

• STAT handling capabilities<br />

• 4 configurable input drawers<br />

• <strong>The</strong> input drawers are freely definable with in total up to 30<br />

targets<br />

• <strong>The</strong> following <strong>Roche</strong> sample carriers are supported:<br />

– cobas ® 6000/cobas® 8000 tray with Hitachi 5 position rack<br />

– Elecsys 2010/cobas® 4000/COBAS Integra 800 tray with<br />

Hitachi 5 position rack<br />

– MODULAR ANALYTICS tray with Hitachi 5 position rack<br />

– COBAS Integra 400+ tray with 15 position rack<br />

In addition support is provided for:<br />

– Several neutral racks<br />

– Several Sysmex trays with 10 pos rack<br />

– Different centrifuge buckets<br />

– Other rack types (Generally RSD Pro and RSA Pro are able<br />

to handle non-<strong>Roche</strong> racks. Please contact your local <strong>Roche</strong><br />

representative for details).<br />

Decap Unit<br />

<strong>The</strong> decap unit removes the tube cap and turns the tube with<br />

the bar code label into a “good to read” position. <strong>The</strong> decap unit<br />

also pauses for a few milliseconds to prevent the buildup of<br />

aerosols.<br />

<strong>The</strong> following listed features are just a few examples of the RSD<br />

Pro and RSA Pro decap unit:<br />

• Different tube types (various closure types and tube dimensions)<br />

can automatically be decapped in one run<br />

• Tubes need not be pre-sorted<br />

• Support of selective decapping according to user defined rules<br />

Recap Unit<br />

<strong>The</strong> RSD Pro and RSA Pro can be equipped with a recapper.<br />

Selective, target specific recapping of plastic tubes based on user<br />

defined rules can be configured. For accurate tube sealing, the<br />

tube type information detected by the standard camera unit is<br />

sent to the recapper. Either the primary or aliquot tubes can be<br />

closed.<br />

<strong>The</strong> following features are also provided by the recap unit:<br />

• <strong>The</strong> sealing of the tubes with an aluminum foil<br />

• <strong>The</strong> support of various tube diameters (between 11.5 mm<br />

and 15.5 mm) and various tube heights (between 65.5 mm<br />

and 102.5 mm).


Aliquoter (RSA Pro only)<br />

<strong>The</strong> basic function of the aliquoter unit is the creation of secondary<br />

tubes based on user configurable rules.<br />

<strong>The</strong> primary features of the aliquoter include:<br />

• Secondary tubes are placed automatically into secondary<br />

tube storage<br />

• Bar code printer with label applicator offers the following:<br />

– A bar code printer with thermal transfer printing<br />

– Bar codes format is configurable to include type, length,<br />

and check digit.<br />

– Additional information such as other sample or patient<br />

information can be printed on the label in human readable<br />

characters<br />

– <strong>The</strong> printed bar code label is also placed on the secondary<br />

tube<br />

• Pipetting unit uses disposable tips and offers the following:<br />

– Customized based on each tube type and order request.<br />

<strong>The</strong> pipetting process is performed sample tube specific<br />

– Liquid level detection<br />

– <strong>The</strong> pipetting process is carry over free due to disposable<br />

tips<br />

Note: <strong>The</strong> disposable tip is not exchanged in the case of<br />

multiple sample uptake<br />

– Up to 28 secondary tubes can be pipetted from one<br />

primary tube<br />

– Up to 384 disposable tips on board in 4 trays<br />

– <strong>The</strong> pipetted volume is calculated based on the single test<br />

requests or based on fixed volume assigned to the sorting<br />

target<br />

– Clot detection is provided during the sample aspiration. If<br />

the tube is affected, an error handling process can be<br />

defined.<br />

*Sysmex products are not sold by <strong>Roche</strong>.<br />

Output (Sorting) Area<br />

All tubes (primary and secondary) are sorted into the output<br />

area. <strong>The</strong> sorting is done according to configurable sorting<br />

criteria.<br />

<strong>The</strong> primary features of the output area are:<br />

• Max sample capacity: up to 1200 tubes<br />

• Up to 8 configurable output drawers<br />

• In total up to 41 sorting targets can be defined<br />

• Parallel sample sorting, aliquoting and archiving can be<br />

performed (recursive workflow)<br />

• <strong>The</strong> system can be configured to turn the primary tube<br />

between 0 and 360 degrees before placing it into the target rack<br />

• Drawers (filled or partly filled) with racks can be changed<br />

while the system is running<br />

• <strong>The</strong> following <strong>Roche</strong> sample carriers are supported:<br />

– cobas® 6000/cobas® 8000 tray with Hitachi 5 position rack<br />

– Elecsys 2010/COBAS Integra 800/cobas 4000 tray with<br />

Hitachi 5 position rack<br />

– MODULAR ANALYTICS tray with Hitachi 5 position rack<br />

– COBAS Integra 400+ tray with 15 position rack<br />

Addition support is available for:<br />

– Several neutral racks<br />

– Several Sysmex* trays with 10 position rack<br />

– Different centrifuge buckets<br />

– Other rack types (Generally RSD Pro and RSA Pro are able<br />

to handle non <strong>Roche</strong> racks as well. Please contact your local<br />

<strong>Roche</strong> representative for details).


Standard Camera<br />

<strong>The</strong> RSD Pro and RSA Pro basic system is equipped with a CCD<br />

camera unit.<br />

<strong>The</strong> camera provides the following basic functions and features:<br />

• <strong>The</strong> cap color and tube dimensions are measured<br />

• Detection if the tube is closed or opened<br />

• <strong>The</strong> cap color is used to distinguish between tubes with the<br />

same tube dimensions<br />

• Processing of the different types of tubes (hematology,<br />

coagulation, serum, plasma and urine tubes) according to<br />

rules based on the received test requests<br />

• Up to 20 different tube types (various closure types, tube<br />

dimensions, cap colors) can be processed in one run<br />

• Positive verification between bar code with material<br />

identification and applied tube type. In the event of<br />

mismatch appropriate error handling procedures can be<br />

configured<br />

• Support of bar code alignment<br />

• Forwarding of the tube type information to the decap,<br />

aliquot and optional recap unit.<br />

Camera Options<br />

<strong>The</strong> following extensions are available:<br />

Tube Type Identification (TTI)<br />

<strong>The</strong> TTI option supports all functions of the basic camera system<br />

(e.g. the registration of cap color and tube dimensions, detection<br />

of whether the tube is open or closed, etc.). In addition, the<br />

recognized tube type (determined by the camera) is uploaded<br />

together with the sample query to the connected IT system.<br />

This information is a prerequisite to enable the IT system to<br />

download test requests (e.g. depending on the sample material).<br />

With tube type identification the cap color and tube dimensions<br />

(tube diameter and tube height) are detected. Up to 20 different<br />

tubes can be handled within one run. <strong>The</strong> tube type identification<br />

compares the measured tube values with the reference values<br />

of the currently known types. <strong>The</strong> tube type identification can be<br />

uploaded to the connected IT system.<br />

Tube Type Identification (TTI)<br />

Cap/no Cap<br />

Tube Dimension<br />

Upload Tube Type<br />

Identification<br />

Tube Type Identification<br />

QS1-Sample Quantity<br />

This camera option is used for the evaluation of the quantity of<br />

centrifuged serum samples. All functions of the “Tube Type<br />

Identification” extensions are supported. In addition, the<br />

following functions and features are delivered:<br />

• Sample volume detection for primary serum tubes<br />

• Upfront sorting rules in the event of insufficient sample<br />

volume<br />

• Use of non conductive tips<br />

QS1-Sample Quantity<br />

Cap/no Cap<br />

Tube Dimension<br />

Volume Calculation<br />

Upload Tube Type<br />

Identification<br />

Liquid Level<br />

Detection


Sample Quantity Detection<br />

A sample image of each processed tube is generated. This<br />

sample image is the basis for the volume calculation.<br />

Note: A minimum of 6.5 mm window for serum analysis must be<br />

available on all tubes for this feature to function.<br />

Sample Quantity Detection<br />

System Connectivity<br />

Host Interface<br />

<strong>The</strong> ASTM host interface of the RSD Pro and RSA Pro allows<br />

fast integration into the laboratory routine. <strong>The</strong> connection can<br />

be either serial or network.<br />

Remote Service and Support<br />

RSD Pro and RSA Pro can be serviced remotely. Configuration<br />

changes, instrument communication traces and software updates<br />

can be carried out via modem access.


Specifications<br />

Throughput: RSD Pro: Up to 1,000 primary tubes per hour<br />

RSA Pro: Up to 405 primary tubes per hour 1<br />

Sample<br />

Identification: Positive sample identification via bar code; able<br />

to handle most of the standard bar code<br />

formats such as Interleaved 2 of 5, Code 39,<br />

Codabar (NW 7), Code 128, others 2<br />

Centrifuge: One or two centrifuges – Hettice Rotanta 46<br />

RSC Robotic<br />

Sample Tube: RSD Pro: Accepts most 3, 5, 7 or 10 ml plastic<br />

tubes with an external tube diameter between<br />

11.5 and 15.5 mm and a total height between<br />

65.5 and 108 mm<br />

COBAS, COBAS INTEGRA, TTA, ELECSYS, LIFE NEEDS ANSWERS,<br />

MODULAR and MYLABONLINE are trademarks of <strong>Roche</strong>.<br />

© 2011 <strong>Roche</strong> <strong>Diagnostics</strong>. All Rights Reserved. 461-50923-0911<br />

<strong>Roche</strong> <strong>Diagnostics</strong><br />

9115 Hague Road<br />

Indianapolis, IN 46256<br />

1-800-981-8863<br />

www.mylabonline.com<br />

RSA Pro: Accepts most 3, 5, 7 or 10 ml plastic<br />

tubes Able to open sample tubes with<br />

hemogard, rubber stopper or screw cap type<br />

closure<br />

Sample Carrier: RD Hitachi MPA racks (5 positions) for input<br />

and output buffer. Other third party rack<br />

possible.<br />

Aliquot Tips: RSA Pro: Use of disposable pipette tips for<br />

secondary tube generation: 1100 µl volume<br />

conductive or 1000 µl volume non conductive<br />

384 tips on board in 4 tip racks<br />

Secondary<br />

Tube: Sarstedt secondary tube 13x75 mm<br />

Sarstedt false bottom 13x75 mm<br />

Greiner Bio-One false bottom 16 mm twin tubes<br />

1. <strong>The</strong> final throughput depends on different parameters as for example the aliquot<br />

volume or the number of aliquots per primary tube<br />

2. Other bar code types can be checked on request<br />

Dimensions: RSD Pro: Width: approx. 6.2 feet<br />

Depth (with touch screen): approx. 5.2 feet<br />

Height (incl. signal lamp): approx. 6.9 feet<br />

Weight: approx. 1918 lbs including centrifuge<br />

RSA Pro: Width: approx. 10.4 feet<br />

Depth (with touch screen): approx. 6.1 feet<br />

Height (incl. signal lamp): approx. 6.5 feet<br />

Weight: approx. 2425 lbs<br />

Operating<br />

Conditions: For indoor use up to 2000 m above sea level<br />

Operating<br />

Temperature: +15 °C to +30 °C (+59 °F to +86 °F)<br />

Air Conditions: 20–80 % relative humidity<br />

Compressed Air: D\Dry and oil free, min 6.0 bar (87.02 psi),<br />

max 8.0 bar (116.03 psi) Consumption approx.<br />

40.0 l (10.6 gals) per min<br />

Consumption approx. 66.0 l (17.4 gals) per min<br />

with recap unit<br />

Power: RSD Pro: 230/115 V, 50–60 Hz, 4950 VA<br />

RSA Pro: 230/115 V, 50–60 Hz, 1800 VA<br />

(with recap unit)<br />

Interface: ASTM protocol<br />

Network connection via TCP/IP or serial<br />

connection via RS 232