pa1778data.pdf
pa1778data.pdf
pa1778data.pdf
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Installation Date: 1955.<br />
U.S. STEEL DUQUESNE WORKS<br />
HAER No. PA-115<br />
(Page 82)<br />
10. Turboblower Number Three Lubrication System: The<br />
lubrication system for turboblower number three is located on the<br />
floor of the building underneath the remains of the turbine. It<br />
is manufactured by the Bowser Company of Fort Wayne, Indiana, and<br />
consists of two oil coolers, two strainers, an oil conditioner,<br />
and a 1/2 hp motor connected to a oil recirculation pump.<br />
Installation Date: 1955.<br />
11. Turboblower Number Three Surface Condenser: A 20,000<br />
square foot capacity Ingersoll - Rand surface condenser is bolted<br />
to the 72" diameter flanged steam connection located on the<br />
underside of the bottom casing for the turbine. The centerline<br />
of the condenser, which is laid out on a north-south axis, is<br />
located 11'-1" from the floor. The condenser consists of a cast<br />
iron shell which encloses a large number of 1/4" diameter tubes.<br />
A 24" flanged inlet and a 24" flanged outlet connection are<br />
located on the western side of the surface condenser near its<br />
northern end for the purpose of circulating service water through<br />
the tubes. Located on the underside of the surface condenser<br />
shell near its center are two 4" diameter flanged condensate<br />
removal connections.<br />
Installation Date: 1955.<br />
a. Air Ejectors: Two Ingersoll - Rand, Series M, Steam<br />
Jet Air Ejectors are attached to the eastern side of the surface<br />
condenser near its centerline. The 3*-3 9/16" long ejectors are<br />
laid out vertically. Each ejector has a 2" diameter screwed<br />
steam inlet connection at its lower end and a 4" diameter flanged<br />
discharge connection at its upper end. Each ejector is attached<br />
to the surface condenser by a 4" diameter flanged suction inlet.<br />
The centerline of the suction inlet is 2'-7 5/8" below the flange<br />
of the discharge connection.<br />
Installation Date: 1968.<br />
12. Turboblower Number Three Condensate Removal Motor/Pump<br />
Assemblies: Located on the floor underneath the surface condenser<br />
are two condensate removal motor/pump assemblies. Laid out on a<br />
east-west axis, the assemblies straddle the centerline of the<br />
surface condenser and are spaced 6•-4 13/16" apart. The northern<br />
most assembly consists of a 25 hp Westinghouse Type CS Line start<br />
Induction Motor rated at 1755 rpra which is connected by a gear<br />
drive to an Ingersoll - Rand 370 gpm centrifugal pump. The<br />
southern most assembly consists of a 24 hp steam turbine,<br />
manufactured by the Terry Steam Turbine Company of Hartford,<br />
Connecticut, rated at 1750 rpm which is connected by a gear drive<br />
to an Ingersoll - Rand 370 gpm centrifugal pump.<br />
Installation Date: 1955.