Installation Date: 1955.<br />

U.S. STEEL DUQUESNE WORKS<br />

HAER No. PA-115<br />

(Page 82)<br />

10. Turboblower Number Three Lubrication System: The<br />

lubrication system for turboblower number three is located on the<br />

floor of the building underneath the remains of the turbine. It<br />

is manufactured by the Bowser Company of Fort Wayne, Indiana, and<br />

consists of two oil coolers, two strainers, an oil conditioner,<br />

and a 1/2 hp motor connected to a oil recirculation pump.<br />

Installation Date: 1955.<br />

11. Turboblower Number Three Surface Condenser: A 20,000<br />

square foot capacity Ingersoll - Rand surface condenser is bolted<br />

to the 72" diameter flanged steam connection located on the<br />

underside of the bottom casing for the turbine. The centerline<br />

of the condenser, which is laid out on a north-south axis, is<br />

located 11'-1" from the floor. The condenser consists of a cast<br />

iron shell which encloses a large number of 1/4" diameter tubes.<br />

A 24" flanged inlet and a 24" flanged outlet connection are<br />

located on the western side of the surface condenser near its<br />

northern end for the purpose of circulating service water through<br />

the tubes. Located on the underside of the surface condenser<br />

shell near its center are two 4" diameter flanged condensate<br />

removal connections.<br />

Installation Date: 1955.<br />

a. Air Ejectors: Two Ingersoll - Rand, Series M, Steam<br />

Jet Air Ejectors are attached to the eastern side of the surface<br />

condenser near its centerline. The 3*-3 9/16" long ejectors are<br />

laid out vertically. Each ejector has a 2" diameter screwed<br />

steam inlet connection at its lower end and a 4" diameter flanged<br />

discharge connection at its upper end. Each ejector is attached<br />

to the surface condenser by a 4" diameter flanged suction inlet.<br />

The centerline of the suction inlet is 2'-7 5/8" below the flange<br />

of the discharge connection.<br />

Installation Date: 1968.<br />

12. Turboblower Number Three Condensate Removal Motor/Pump<br />

Assemblies: Located on the floor underneath the surface condenser<br />

are two condensate removal motor/pump assemblies. Laid out on a<br />

east-west axis, the assemblies straddle the centerline of the<br />

surface condenser and are spaced 6•-4 13/16" apart. The northern<br />

most assembly consists of a 25 hp Westinghouse Type CS Line start<br />

Induction Motor rated at 1755 rpra which is connected by a gear<br />

drive to an Ingersoll - Rand 370 gpm centrifugal pump. The<br />

southern most assembly consists of a 24 hp steam turbine,<br />

manufactured by the Terry Steam Turbine Company of Hartford,<br />

Connecticut, rated at 1750 rpm which is connected by a gear drive<br />

to an Ingersoll - Rand 370 gpm centrifugal pump.<br />

Installation Date: 1955.