19.01.2013 Views

System Description RIO / microLine

System Description RIO / microLine

System Description RIO / microLine

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Expansion Modules<br />

Axis Interface <strong>RIO</strong> A10-10<br />

Slide contacts<br />

for internal bus<br />

52<br />

Inputs<br />

X1.0 ... X1.7<br />

X2.0 ... 2.7<br />

Supply<br />

voltage:<br />

+24 V DC<br />

0 V DC<br />

PE<br />

Contacts for<br />

internal bus<br />

LEDs for<br />

control state of<br />

inputs/outputs<br />

Potential relaying:<br />

0 V DC<br />

The ROI A10-10 axis interface allows you to control a position-controlled axis<br />

by means of an actual value system and an analog setpoint output. It sends<br />

the encoder actual value to the controller and generates an analog output<br />

voltage from the speed setpoint of the PLC/CNC. It also has a number of<br />

digital inputs/outputs that are directly sent to or controlled by the PLC/CNC.<br />

The axis interface has no intelligence of its own (e.g. position controller or<br />

similar). It merely provides interfaces.<br />

The <strong>RIO</strong> A10-10 is designed to be used directly on the PLC, because the<br />

standard field buses demonstrate non-deterministic behaviour. The SCHLEICHER<br />

<strong>microLine</strong> and XCx controllers are suitable.<br />

Interfaces:<br />

• Incremental/absolute encoder interface (similar to RS422).<br />

If an incremental encoder is connected, the encoder actual value supplied<br />

to the controller is generated by an up/down counter counting the encoder<br />

pulses. If an absolute value encoder is connected, the encoder supplies the<br />

actual value directly.<br />

• Inputs for limit switch, reference cam, servo amplifier ready (digital, 24 V)<br />

• Output for controller enable (digital, 24 V)<br />

• Analog output (±10 V).<br />

A corresponding analog output voltage is generated from the speed<br />

setpoint supplied by the controller.<br />

• Freely configurable combination input/output (digital, 24 V)<br />

The module possesses limited functionalities of its own. The analog output<br />

and the controller enable can be shut down without involving the PLC/CNC.<br />

You can set the events (ready, limit switch, cable break, etc.) that lead to<br />

shutdown. The watchdog function deactivates the module if the internal bus is<br />

interrupted for more than 80 ms; all outputs are shut down. The encoder<br />

actual value remains valid and the incremental encoder signals continue to<br />

be processed.<br />

You can alter the module configuration via the controller:<br />

• Encoder type (incremental/absolute)<br />

• Zero signal processing<br />

• Code, data length and clock rate of actual value encoder<br />

• Delete actual value<br />

• Monitor ready, limit switch and cable break<br />

PE<br />

Block diagram<br />

Encoder types<br />

Incremental encoder<br />

Signals A, /A, B, /B, NULL, /NULL<br />

Method Periodic (max → min or<br />

min → max)<br />

Counting Up to 500 kHz<br />

frequency<br />

Width 32-bit<br />

Range –231 ... 231 –1<br />

Flank 4-fold<br />

evaluation<br />

Absolute value encoder<br />

Signals A, /A, CLOCK, /CLOCK,<br />

GNDCLOCK<br />

Protocol SSI<br />

Coding Gray, binary<br />

Data length 24 / 21 / 13 bits<br />

Clock pulse 100 / 200 / 500 /<br />

1000 KHz<br />

Adaptation Evaluation of A, A/ detects<br />

whether CLOCK, /CLOCK<br />

and A, /A are correctly<br />

connected or inverted.<br />

Inversions are corrected in<br />

the module.<br />

<strong>System</strong> <strong>Description</strong> <strong>RIO</strong> / <strong>microLine</strong>