Expansion Modules Analog • 4 Inputs • 4 Outputs • ±10V RIO 4AI/4AO ±10V Slide contacts for internal bus 44 Inputs X1.0 ... X1.7 Outputs X2.0 ... 2.7 Supply voltage: +24 V DC 0 V DC PE Contacts for internal bus Channel monitoring (yellow: cursor) Potential relaying: 0 V DC The RIO 4AI/4AO ±10V analog module provides 4 differential input channels and 4 output channels for DC signals in the range –10 V to +10 V. The inputs are four-wire, the outputs three-wire. The analog input and output signals are digitalized with 12 bits within 2 s. PE Block diagram Technical Data RIO 4AI/4AO ±10V Article number R5.364.0070.0 Number of inputs/outputs 4 inputs (differential), 4 outputs Data width 2 bytes per channel I/O External supply voltage DC 24 V (±20%, max. 5% residual ripple) Power consumption 4.3 W (analog outputs max. loaded) from external 24 V supply 0.325 W from internal 5 V supply Connection system Inputs Four-wire Input range –10 ... +10 V Resolution 12-bit / 4.88 mV Conversion time 2 ms Input current –15 ... +15 μA Input resistance 1 MΩ Isolation Outputs From internal bus Output range –10 ... +10 V Resolution 12-bit / 4.88 mV Refresh rate 2 ms Output current –10 ... +10 mA Short-circuit current / duration 20 mA / ∞ Isolation From internal bus For general technical data see page 68 System Description RIO / microLine
Expansion Modules Analog • 4 Inputs • 4 Outputs • 0...20 mA RIO 4AI/4AO 20mA Analog • 4 Inputs • 4 Outputs • 4...20 mA RIO 4AI/4AO 4-20mA Slide contacts for internal bus Inputs X1.0 ... X1.7 Outputs X2.0 ... 2.7 Supply voltage: +24 V DC 0 V DC PE Contacts for internal bus Channel monitoring (yellow: cursor) Potential relaying: 0 V DC The RIO 4AI/4AO 20mA and RIO 4AI/4AO 4-20mA analog modules provide 4 single-ended input channels for input currents of 0 to 20 mA and 4 to 20 mA, and 4 output channels. The 4 mA system allows reliable detection of cable breaks. The data format of the modules can be set for use with a S5/S7 controller using a service code via the bus coupler or PLC. The inputs and outputs are isolated from the internal bus. PE Block diagram Technical Data RIO 4AI/4AO 20mA RIO 4AI/4AO 4-20mA Article number R5.364.0080.0 R5.364.0090.0 Number of inputs/outputs 4 inputs (single-ended), 4 outputs Data width 2 bytes per channel I/O External supply voltage DC 24 V (±20%, max. 5% residual ripple) Power consumption 3.6 W from external 24 V supply 0.325 W from internal 5 V supply Connection system Inputs Three-wire (with RIO KE 16 terminal extension: four-wire) Input range 0 ... 20 mA 4 ... 20 mA Resolution 12-bit / 4.88 μA 11-bit / 7.81 μA Conversion time 2 ms Input load 100 Ω, acceptable continuous load 200 mW Permissible continuous input current ±40 mA Perm. continuous input voltage ±4 V Channel crosstalk Outputs –74 dB (f < 100 Hz) Output range 0 ... 20 mA 0 mA; 4 ... 20 mA Resolution 12-bit / 4.88 μA 10-bit / 15.625 μA Refresh rate 2 ms Output load 0 ... 500 Ω Short-circuit current / duration 20 mA / ∞ Output voltage 0 ... 10 V For general technical data see page 68 System Description RIO / microLine 45
- Page 1 and 2: RIO Field Bus System / microLine PL
- Page 3 and 4: 57 58 59 60 61 63 64 65 65 66 66 67
- Page 5 and 6: Components in the RIO System microL
- Page 7 and 8: ... and in the Detail Spring-Loaded
- Page 9 and 10: Simply Faster - CANopen PCS What is
- Page 11 and 12: Systems at a Glance DeviceNet is a
- Page 13 and 14: microLine PLC Controller microLine
- Page 15 and 16: Technical Data MCS 20-21R MCS 20-20
- Page 17 and 18: Technical Data MCS 20-11R MCS 20-10
- Page 19 and 20: RIO Bus Couplers The bus coupler co
- Page 21 and 22: Functions on the BC Bus Coupler It
- Page 23 and 24: Bus Couplers Bus Coupler • EC •
- Page 25 and 26: Bus Couplers Bus Coupler • EC •
- Page 27 and 28: Bus Couplers Bus Coupler • EC •
- Page 29 and 30: Bus Couplers Bus Coupler • EC •
- Page 31 and 32: Bus Couplers Bus Coupler • EC •
- Page 33 and 34: RIO Expansion Modules Digital and a
- Page 35 and 36: Expansion Modules Digital • 16 In
- Page 37 and 38: Expansion Modules Digital • 16 Ou
- Page 39 and 40: Expansion Modules Digital • 4 Out
- Page 41 and 42: Expansion Modules Digital • 8 Inp
- Page 43: Expansion Modules Analog • 4 Inpu
- Page 47 and 48: Expansion Modules Temperature Modul
- Page 49 and 50: Technical Data RIO C24-10 Article n
- Page 51 and 52: Technical Data RIO P24-10 RIO P05-1
- Page 53 and 54: Technical data RIO A10-10 Article n
- Page 55 and 56: System Description RIO / microLine
- Page 57 and 58: RIO Compact I/O Our digital compact
- Page 59 and 60: Compact I/O Digital • 16 Inputs
- Page 61 and 62: Compact I/O Digital • 8 Inputs
- Page 63 and 64: Software • Multiprog • Prodoc U
- Page 65 and 66: Software Programming Software Prodo
- Page 67 and 68: Accessories Cables, Connectors, Sma
- Page 69 and 70: Dimensions Bus Couplers BC microLin
- Page 71 and 72: Always There for You Schleicher sta
Expansion Modules<br />
Analog • 4 Inputs • 4 Outputs • ±10V <strong>RIO</strong> 4AI/4AO ±10V<br />
Slide contacts<br />
for internal bus<br />
44<br />
Inputs<br />
X1.0 ... X1.7<br />
Outputs<br />
X2.0 ... 2.7<br />
Supply<br />
voltage:<br />
+24 V DC<br />
0 V DC<br />
PE<br />
Contacts for<br />
internal bus<br />
Channel<br />
monitoring<br />
(yellow: cursor)<br />
Potential relaying:<br />
0 V DC<br />
The <strong>RIO</strong> 4AI/4AO ±10V analog module provides 4 differential input channels<br />
and 4 output channels for DC signals in the range –10 V to +10 V. The inputs<br />
are four-wire, the outputs three-wire. The analog input and output signals are<br />
digitalized with 12 bits within 2 s.<br />
PE<br />
Block diagram<br />
Technical Data <strong>RIO</strong> 4AI/4AO ±10V<br />
Article number R5.364.0070.0<br />
Number of inputs/outputs 4 inputs (differential), 4 outputs<br />
Data width 2 bytes per channel I/O<br />
External supply voltage DC 24 V (±20%, max. 5% residual ripple)<br />
Power consumption 4.3 W (analog outputs max. loaded) from external 24 V supply<br />
0.325 W from internal 5 V supply<br />
Connection system<br />
Inputs<br />
Four-wire<br />
Input range –10 ... +10 V<br />
Resolution 12-bit / 4.88 mV<br />
Conversion time 2 ms<br />
Input current –15 ... +15 μA<br />
Input resistance 1 MΩ<br />
Isolation<br />
Outputs<br />
From internal bus<br />
Output range –10 ... +10 V<br />
Resolution 12-bit / 4.88 mV<br />
Refresh rate 2 ms<br />
Output current –10 ... +10 mA<br />
Short-circuit current / duration 20 mA / ∞<br />
Isolation From internal bus<br />
For general technical data see page 68<br />