System Description RIO / microLine
System Description RIO / microLine System Description RIO / microLine
Bus Couplers Bus Coupler • BC • CANopen RIO BC CANopen PCS LEDs for module and field bus diagnosis 28 LEDs for modes Mode switch Keypad Field bus interface Contacts for internal bus Display +24 VDC 0 VDC The RIO BC CANopen PCS Standard bus coupler combines the digital, analog and function modules with the CANopen field bus. A bus node comprises the bus coupler and up to eight expansion modules with 128 digital or 56 analog channels. For special features of CANopen PCS → page 9. In order to achieve compatibility with various PLC standards you can use the byte-swap function to swap the two bytes of a data word. As the standard bus coupler, the RIO BC CANopen offers not only run mode but also other modes for commissioning, diagnosis and comprehensive service functions. These are operated via the keypad and display. On controllers with limited address space the diagnosis range can be switched off. This reduced the data width for transmission by 4 bytes. PE Block diagram Technical Data RIO BC CANopen PCS Article number R5.363.0050.0 Field bus CANopen Bus connection 1x open style connector 5-pin Node-ID Address range 0 ... 127, set via keypad and display Baud rate up to 1000 kbaud, set via keypad and display Diagnosis interface Switch on/off via keypad and display Max. I/O range internal 64 bytes input data 64 bytes output data External supply voltage DC 24 V (±20%, max. 5% residual ripple) Power supply to CAN interface DC 11 ... 30V (meets CAN specification) Power consumption Bus coupler: 5 W from external 24 V supply Connected modules: max. 5 W via internal 5 V supply Number of attachable I/O modules 8 For general technical data see page 68 System Description RIO / microLine
Bus Couplers Bus Coupler • EC • CANopen RIO EC CANopen PCS LEDs for module and field bus diagnosis Address setting Field bus interface Contacts for internal bus +24 VDC 0 VDC The RIO EC CANopen PCS Economy bus coupler combines the digital, analog and function modules with the CANopen field bus. A bus node comprises the bus coupler and up to eight expansion modules with 128 digital or 56 analog channels. For special features of CANopen PCS → page 9. In order to achieve compatibility with various PLC standards you can use the byte-swap function to swap the two bytes of a data word. As an Economy bus coupler, the RIO EC CANopen allows you to create an inexpensive bus node. It can be replaced with a BC bus coupler with advanced service and diagnosis functions, without any other alterations. PE Block diagram Technical Data RIO EC CANopen PCS Article number R5.363.0120.0 Field bus CANopen Bus connection 1x open style connector 5-pin Node-ID Address range 0 ... 127, setting via DIP switches Baud rate Up to 1000 Kbaud, setting via DIP switches Max. I/O range internal 64 bytes input data 64 bytes output data External supply voltage DC 24 V (±20%, max. 5% residual ripple) Power supply to CAN interface DC 11 ... 30 V (meets CAN specification) Power consumption Bus coupler: 5 W from external 24 V supply Connected modules: max. 5 W via internal 5 V supply Number of attachable I/O modules 8 For general technical data see page 68 System Description RIO / microLine 29
- Page 1 and 2: RIO Field Bus System / microLine PL
- Page 3 and 4: 57 58 59 60 61 63 64 65 65 66 66 67
- Page 5 and 6: Components in the RIO System microL
- Page 7 and 8: ... and in the Detail Spring-Loaded
- Page 9 and 10: Simply Faster - CANopen PCS What is
- Page 11 and 12: Systems at a Glance DeviceNet is a
- Page 13 and 14: microLine PLC Controller microLine
- Page 15 and 16: Technical Data MCS 20-21R MCS 20-20
- Page 17 and 18: Technical Data MCS 20-11R MCS 20-10
- Page 19 and 20: RIO Bus Couplers The bus coupler co
- Page 21 and 22: Functions on the BC Bus Coupler It
- Page 23 and 24: Bus Couplers Bus Coupler • EC •
- Page 25 and 26: Bus Couplers Bus Coupler • EC •
- Page 27: Bus Couplers Bus Coupler • EC •
- Page 31 and 32: Bus Couplers Bus Coupler • EC •
- Page 33 and 34: RIO Expansion Modules Digital and a
- Page 35 and 36: Expansion Modules Digital • 16 In
- Page 37 and 38: Expansion Modules Digital • 16 Ou
- Page 39 and 40: Expansion Modules Digital • 4 Out
- Page 41 and 42: Expansion Modules Digital • 8 Inp
- Page 43 and 44: Expansion Modules Analog • 4 Inpu
- Page 45 and 46: Expansion Modules Analog • 4 Inpu
- Page 47 and 48: Expansion Modules Temperature Modul
- Page 49 and 50: Technical Data RIO C24-10 Article n
- Page 51 and 52: Technical Data RIO P24-10 RIO P05-1
- Page 53 and 54: Technical data RIO A10-10 Article n
- Page 55 and 56: System Description RIO / microLine
- Page 57 and 58: RIO Compact I/O Our digital compact
- Page 59 and 60: Compact I/O Digital • 16 Inputs
- Page 61 and 62: Compact I/O Digital • 8 Inputs
- Page 63 and 64: Software • Multiprog • Prodoc U
- Page 65 and 66: Software Programming Software Prodo
- Page 67 and 68: Accessories Cables, Connectors, Sma
- Page 69 and 70: Dimensions Bus Couplers BC microLin
- Page 71 and 72: Always There for You Schleicher sta
Bus Couplers<br />
Bus Coupler • BC • CANopen <strong>RIO</strong> BC CANopen PCS<br />
LEDs for module<br />
and field bus<br />
diagnosis<br />
28<br />
LEDs for<br />
modes<br />
Mode switch<br />
Keypad<br />
Field bus<br />
interface<br />
Contacts for<br />
internal bus<br />
Display<br />
+24 VDC<br />
0 VDC<br />
The <strong>RIO</strong> BC CANopen PCS Standard bus coupler combines the digital, analog<br />
and function modules with the CANopen field bus. A bus node comprises<br />
the bus coupler and up to eight expansion modules with 128 digital or 56<br />
analog channels. For special features of CANopen PCS → page 9.<br />
In order to achieve compatibility with various PLC standards you can use the<br />
byte-swap function to swap the two bytes of a data word.<br />
As the standard bus coupler, the <strong>RIO</strong> BC CANopen offers not only run mode<br />
but also other modes for commissioning, diagnosis and comprehensive service<br />
functions. These are operated via the keypad and display. On controllers with<br />
limited address space the diagnosis range can be switched off. This reduced<br />
the data width for transmission by 4 bytes.<br />
PE<br />
Block diagram<br />
Technical Data <strong>RIO</strong> BC CANopen PCS<br />
Article number R5.363.0050.0<br />
Field bus CANopen<br />
Bus connection 1x open style connector 5-pin<br />
Node-ID Address range 0 ... 127, set via keypad and display<br />
Baud rate up to 1000 kbaud, set via keypad and display<br />
Diagnosis interface Switch on/off via keypad and display<br />
Max. I/O range internal 64 bytes input data<br />
64 bytes output data<br />
External supply voltage DC 24 V (±20%, max. 5% residual ripple)<br />
Power supply to CAN interface DC 11 ... 30V (meets CAN specification)<br />
Power consumption Bus coupler: 5 W from external 24 V supply<br />
Connected modules: max. 5 W via internal 5 V supply<br />
Number of attachable I/O modules 8<br />
For general technical data see page 68<br />
<strong>System</strong> <strong>Description</strong> <strong>RIO</strong> / <strong>microLine</strong>