Vacuum Equipment<br />

42<br />

The Mitsubishi Variable Speed Drive<br />

System is designed to provide accurate<br />

vacuum level control on modern dairy<br />

farms. The control is programmed to follow<br />

a vacuum level set by the operator of the<br />

dairy. This level is maintained by the use<br />

of a Vacuum Transducer mounted in the<br />

Vacuum line and connected back to the<br />

VSD. The Transducer provides a constant<br />

feedback to the VSD which in turn changes<br />

the speed based on system demand.<br />

Using the keypad, the desired vacuum<br />

level is entered and the VSD will maintain<br />

that reading at all times. During milking<br />

the VSD will vary in speed to keep the set<br />

point satisfied. The VSD updates the<br />

feedback loop as many as 50 times per<br />

second, t<strong>here</strong>fore ensuring the rapid<br />

response to changes in the vacuum level of<br />

the system.<br />

Adjustments can be made to increase or<br />

decrease the responsiveness of the system.<br />

Factory pre-sets are most common without<br />

any changes necessary. Transducer and<br />

Cord Set are required accessories for<br />

operation of the VSD.<br />

CTA Vacuum Pumps<br />

Pumps come complete with Silencer, Oiler, Pulley and zinc terminal valve.<br />

Pump performance, or CFM, varies according to motor size, ambient<br />

temperature, humidity, air pressure, elevation, and many other factors. The<br />

CFM’s and RPM’s on the chart indicate the pump’s performance at sea level, at<br />

68˚F and with the motor size specified.<br />

Part Nu. Motor HP / KW RPM CFM / LT Empty Wt.<br />

100/060 1.5HP / 1.1 KW 1400 12 CFM/ 350 Lt 46 lbs.<br />

100/050 2HP / 1.5 KW 1250 17 CFM/ 500 Lt 78 lbs.<br />

100/040 3HP / 2.2 KW 1250 26 CFM/ 750 Lt 82 lbs.<br />

or 2HP / 1.5 KW 1100 21 CFM/ 600 Lt<br />

100/030 4HP / 3 KW 1200 35 CFM/ 1000 Lt 121 lbs.<br />

or 3HP / 2.2 KW 900 32 CFM/ 900 Lt<br />

Vacuum<br />

Pump Oil<br />

Non-foaming Vacuum<br />

Pump Oil flows freely even<br />

at low temperatures.<br />

Rust-inhibiting and will<br />

not form sludge. Save—<br />

order by the case.<br />

931 Pump Oil, Qt. 2.5 lbs.<br />

Carton of 12 weighs 25 lbs.<br />

932 Pump Oil, Gal 8 lbs.<br />

Carton of 6 weighs 49 lbs.<br />

Variable Speed<br />

Drive<br />

CTA PUMP DATA CHART<br />

500/077 Vane for 100/030 Pump 500/080 Vane for 100/060 Pump<br />

500/078 Vane for 100/040 Pump 500/100A Universal Oiler<br />

500/079 Vane for 100/050 Pump<br />

Vacuum Pumps and Assembly<br />

Order Motor<br />

separately.<br />

See Index.<br />

100/060<br />

100/050<br />

• Standard Nema 1 enclosed<br />

• Adjustable vacuum set point<br />

• Automatic vacuum regulation through the use of a<br />

line mounted transducer (sold separately)<br />

• Simple fine tune adjustments for added flexibility<br />

• Vacuum bypass switch contact for full speed operation<br />

• Ultra-fast vacuum signal response update<br />

(up to 50 times per second)<br />

• Simple installation<br />

101-2050 Mitsubishi VSD System for 5HP motor for single phase 230V power.<br />

101-2075 Mitsubishi VSD System for 7.5HP motor for single phase 230V power.<br />

101-2100 Mitsubishi VSD System for 10HP motor for single phase 230V power.<br />

101-2150 Mitsubishi VSD System for 15HP motor for single phase 230V power.<br />

101-2200 Mitsubishi VSD System for 20HP motor for single phase 230V power.<br />

101-2250 Mitsubishi VSD System for 25HP motor for single phase 230V power.<br />

101-2300 Mitsubishi VSD System for 30HP motor for single phase 230V power.<br />

101-4100 Mitsubishi VSD System for 10HP motor for three phase 460V power.<br />

101-4150 Mitsubishi VSD System for 15HP motor for three phase 460V power.<br />

101-4200 Mitsubishi VSD System for 20HP motor for three phase 460V power.<br />

101-4250 Mitsubishi VSD System for 25HP motor for three phase 460V power.<br />

101-4300 Mitsubishi VSD System for 30HP motor for three phase 460V power.<br />

101-9001 Vacuum Transducer for VSD, 0-30” Hg, required.<br />

101-9002 Cord Set for Mitsubishi VSD System, required.<br />

101-9003 Relay for Mitsubishi VSD System.<br />

101-9004 Socket Base for Mitsubishi VSD System.<br />

100/040<br />

Sized right for the small to medium sized farm. No need<br />

to sell used pumps when your customers can easily afford a<br />

new top-of-the-line Strangko pump. Featuring high capacity<br />

and very low oil consumption, these pumps are truly<br />

efficient and surprisingly quiet. The shaft is fully supported<br />

on both ends by ball bearings. Oiler drips on both ends for<br />

constant lubrication of vanes and bearings. No oil reclaimer<br />

needed these pumps. Pumps comes complete with pulley,<br />

oiler and muffler.<br />

SH30A Pump complete, 1300 RPM, 2 HP, 25 CFM ASME.<br />

Handle 3–4 milkers. Wt. 67 lbs.<br />

Replacement Parts<br />

3103204 Repl. vanes for SH20A, set of 4. 3105360 Repl. Muffler for SH20A<br />

3105204 Repl. vanes for SH30A, set of 4. 3105380 Repl. Muffler for SH30A<br />

3105230 Repl. Oiler Assembly<br />

SH30AT SH30A Pump on 45 liter tank with two 2” openings. Belt, belt<br />

guard, oiler and muffler included. Wt. 107 lbs.<br />

The <strong>Coburn</strong> Vacuum Regulator or the Interpuls Stabilvac Regulator are highly<br />

recommended for use with the Strangko Vacuum Pumps. See Index.<br />

800-776-7042 Quality and Service Since 1925 www.coburn.com<br />

100/030