Vacuum Equipment<br />
42<br />
The Mitsubishi Variable Speed Drive<br />
System is designed to provide accurate<br />
vacuum level control on modern dairy<br />
farms. The control is programmed to follow<br />
a vacuum level set by the operator of the<br />
dairy. This level is maintained by the use<br />
of a Vacuum Transducer mounted in the<br />
Vacuum line and connected back to the<br />
VSD. The Transducer provides a constant<br />
feedback to the VSD which in turn changes<br />
the speed based on system demand.<br />
Using the keypad, the desired vacuum<br />
level is entered and the VSD will maintain<br />
that reading at all times. During milking<br />
the VSD will vary in speed to keep the set<br />
point satisfied. The VSD updates the<br />
feedback loop as many as 50 times per<br />
second, t<strong>here</strong>fore ensuring the rapid<br />
response to changes in the vacuum level of<br />
the system.<br />
Adjustments can be made to increase or<br />
decrease the responsiveness of the system.<br />
Factory pre-sets are most common without<br />
any changes necessary. Transducer and<br />
Cord Set are required accessories for<br />
operation of the VSD.<br />
CTA Vacuum Pumps<br />
Pumps come complete with Silencer, Oiler, Pulley and zinc terminal valve.<br />
Pump performance, or CFM, varies according to motor size, ambient<br />
temperature, humidity, air pressure, elevation, and many other factors. The<br />
CFM’s and RPM’s on the chart indicate the pump’s performance at sea level, at<br />
68˚F and with the motor size specified.<br />
Part Nu. Motor HP / KW RPM CFM / LT Empty Wt.<br />
100/060 1.5HP / 1.1 KW 1400 12 CFM/ 350 Lt 46 lbs.<br />
100/050 2HP / 1.5 KW 1250 17 CFM/ 500 Lt 78 lbs.<br />
100/040 3HP / 2.2 KW 1250 26 CFM/ 750 Lt 82 lbs.<br />
or 2HP / 1.5 KW 1100 21 CFM/ 600 Lt<br />
100/030 4HP / 3 KW 1200 35 CFM/ 1000 Lt 121 lbs.<br />
or 3HP / 2.2 KW 900 32 CFM/ 900 Lt<br />
Vacuum<br />
Pump Oil<br />
Non-foaming Vacuum<br />
Pump Oil flows freely even<br />
at low temperatures.<br />
Rust-inhibiting and will<br />
not form sludge. Save—<br />
order by the case.<br />
931 Pump Oil, Qt. 2.5 lbs.<br />
Carton of 12 weighs 25 lbs.<br />
932 Pump Oil, Gal 8 lbs.<br />
Carton of 6 weighs 49 lbs.<br />
Variable Speed<br />
Drive<br />
CTA PUMP DATA CHART<br />
500/077 Vane for 100/030 Pump 500/080 Vane for 100/060 Pump<br />
500/078 Vane for 100/040 Pump 500/100A Universal Oiler<br />
500/079 Vane for 100/050 Pump<br />
Vacuum Pumps and Assembly<br />
Order Motor<br />
separately.<br />
See Index.<br />
100/060<br />
100/050<br />
• Standard Nema 1 enclosed<br />
• Adjustable vacuum set point<br />
• Automatic vacuum regulation through the use of a<br />
line mounted transducer (sold separately)<br />
• Simple fine tune adjustments for added flexibility<br />
• Vacuum bypass switch contact for full speed operation<br />
• Ultra-fast vacuum signal response update<br />
(up to 50 times per second)<br />
• Simple installation<br />
101-2050 Mitsubishi VSD System for 5HP motor for single phase 230V power.<br />
101-2075 Mitsubishi VSD System for 7.5HP motor for single phase 230V power.<br />
101-2100 Mitsubishi VSD System for 10HP motor for single phase 230V power.<br />
101-2150 Mitsubishi VSD System for 15HP motor for single phase 230V power.<br />
101-2200 Mitsubishi VSD System for 20HP motor for single phase 230V power.<br />
101-2250 Mitsubishi VSD System for 25HP motor for single phase 230V power.<br />
101-2300 Mitsubishi VSD System for 30HP motor for single phase 230V power.<br />
101-4100 Mitsubishi VSD System for 10HP motor for three phase 460V power.<br />
101-4150 Mitsubishi VSD System for 15HP motor for three phase 460V power.<br />
101-4200 Mitsubishi VSD System for 20HP motor for three phase 460V power.<br />
101-4250 Mitsubishi VSD System for 25HP motor for three phase 460V power.<br />
101-4300 Mitsubishi VSD System for 30HP motor for three phase 460V power.<br />
101-9001 Vacuum Transducer for VSD, 0-30” Hg, required.<br />
101-9002 Cord Set for Mitsubishi VSD System, required.<br />
101-9003 Relay for Mitsubishi VSD System.<br />
101-9004 Socket Base for Mitsubishi VSD System.<br />
100/040<br />
Sized right for the small to medium sized farm. No need<br />
to sell used pumps when your customers can easily afford a<br />
new top-of-the-line Strangko pump. Featuring high capacity<br />
and very low oil consumption, these pumps are truly<br />
efficient and surprisingly quiet. The shaft is fully supported<br />
on both ends by ball bearings. Oiler drips on both ends for<br />
constant lubrication of vanes and bearings. No oil reclaimer<br />
needed these pumps. Pumps comes complete with pulley,<br />
oiler and muffler.<br />
SH30A Pump complete, 1300 RPM, 2 HP, 25 CFM ASME.<br />
Handle 3–4 milkers. Wt. 67 lbs.<br />
Replacement Parts<br />
3103204 Repl. vanes for SH20A, set of 4. 3105360 Repl. Muffler for SH20A<br />
3105204 Repl. vanes for SH30A, set of 4. 3105380 Repl. Muffler for SH30A<br />
3105230 Repl. Oiler Assembly<br />
SH30AT SH30A Pump on 45 liter tank with two 2” openings. Belt, belt<br />
guard, oiler and muffler included. Wt. 107 lbs.<br />
The <strong>Coburn</strong> Vacuum Regulator or the Interpuls Stabilvac Regulator are highly<br />
recommended for use with the Strangko Vacuum Pumps. See Index.<br />
800-776-7042 Quality and Service Since 1925 www.coburn.com<br />
100/030