On Line Tender Notice No.47of 2012-13 Administration of Dadra & Nagar Haveli, U.T., Office of the Medical Superintendent, Shri Vinoba Bhave Civil Hospital No. MS/VBCH/2012-13/ME/69/6632 Silvassa. e-Tender Notice Date:16.10.2012 Tender for Purchase of Medical Equipments for Shri Vinoba Bhave Civil Hospital, Dadra & Nagar Haveli, Silvassa. The Medical Superintendent, Shri Vinoba Bhave Civil Hospital, Dadra & Nagar Haveli, Silvassa on behalf of President of India, invites on line tender on https://dnh.nprocure.com from the Manufactures/Authorized Dealers/Suppliers for supply of below mentioned equipment. Sr. No. Particulars EMD 1. Purchase of Medical Equipments for Shri Vinoba Bhave Civil Hospital a. Cardiology Equipments `.88,750/b. Neonatology Equipments `.1,63,000/c. Ophthalmology Equipments 1. Under VBCH `.87,500/- 2. Under DBCP `.50,000/d. Dermatology Equipments `.63,050/e. Pathology Equipments `.1,02,750/f. Orthopedic Equipments `.1,14,250/g. Physiotherapy Equipments `.2,21,500/h. ENT Equipments `.1,43,000/i. Urology Equipments `.11,250/j. CSSD Equipments `.60,750/k. General Equipments `.26,000/l. Solar Water Heater Plant `.1,00,000/m. Instruments `.50,000/- Tender Fees `.2000/- Non – Refundable

On Line <strong>Tender</strong> <strong>Notice</strong> No.47<strong>of</strong> 2012-13<br />

Administration <strong>of</strong> <strong>Dadra</strong> & Nagar Haveli, U.T.,<br />

Office <strong>of</strong> the <strong>Medical</strong> Superintendent,<br />

Shri Vinoba Bhave Civil Hospital<br />

No. MS/VBCH/2012-13/ME/69/6632 Silvassa.<br />

e-<strong>Tender</strong> <strong>Notice</strong><br />

Date:16.10.2012<br />

<strong>Tender</strong> <strong>for</strong> <strong>Purchase</strong> <strong>of</strong> <strong>Medical</strong> <strong>Equipments</strong> <strong>for</strong> Shri Vinoba Bhave Civil<br />

Hospital, <strong>Dadra</strong> & Nagar Haveli, Silvassa.<br />

The <strong>Medical</strong> Superintendent, Shri Vinoba Bhave Civil Hospital, <strong>Dadra</strong> &<br />

Nagar Haveli, Silvassa on behalf <strong>of</strong> President <strong>of</strong> India, invites on line tender on<br />

https://dnh.nprocure.com from the Manufactures/Authorized Dealers/Suppliers <strong>for</strong><br />

supply <strong>of</strong> below mentioned equipment.<br />

Sr.<br />

No.<br />

Particulars EMD<br />

1.<br />

<strong>Purchase</strong> <strong>of</strong> <strong>Medical</strong> <strong>Equipments</strong> <strong>for</strong> Shri Vinoba<br />

Bhave Civil Hospital<br />

a. Cardiology <strong>Equipments</strong> `.88,750/b.<br />

Neonatology <strong>Equipments</strong> `.1,63,000/c.<br />

Ophthalmology <strong>Equipments</strong><br />

1. Under VBCH `.87,500/-<br />

2. Under DBCP `.50,000/d.<br />

Dermatology <strong>Equipments</strong> `.63,050/e.<br />

Pathology <strong>Equipments</strong> `.1,02,750/f.<br />

Orthopedic <strong>Equipments</strong> `.1,14,250/g.<br />

Physiotherapy <strong>Equipments</strong> `.2,21,500/h.<br />

ENT <strong>Equipments</strong> `.1,43,000/i.<br />

Urology <strong>Equipments</strong> `.11,250/j.<br />

CSSD <strong>Equipments</strong> `.60,750/k.<br />

General <strong>Equipments</strong> `.26,000/l.<br />

Solar Water Heater Plant `.1,00,000/m.<br />

Instruments `.50,000/-<br />

<strong>Tender</strong><br />

Fees<br />

`.2000/-<br />

Non – Refundable


Bid document downloading Start Date : 17.10.2012<br />

Bid document downloading End Date : 06.11.2012, 15:00 Hrs.<br />

Last Date & Time <strong>for</strong> receipt <strong>of</strong> Bid : 07.11.2012, 11.00 Hrs.<br />

Preliminary Stage Bid Opening Date : 07.11.2012, 11.10 Hrs<br />

Technical Stage Bid Opening Date : 07.11.2012, 11.30 Hrs<br />

Commercial Stage Bid Opening Date : 10.11.2012, 12.00 Hrs<br />

Bidders have to submit price bid in Electronic <strong>for</strong>mat only on<br />

https://dnh.procure.com website till the last date <strong>and</strong> time <strong>for</strong> submission. Price Bid in<br />

Physical <strong>for</strong>mat shall not be accepted in any case.<br />

Bid submission should be done along with tender Fees <strong>and</strong> EMD in original<br />

by R.P.A.D./Speed Post in the <strong>of</strong>fice <strong>of</strong> the undersigned. However, <strong>Tender</strong> Inviting<br />

Authority shall not be responsible <strong>for</strong> any postal delay.<br />

1. The <strong>Tender</strong> Fees should not be <strong>for</strong>warded by cash.<br />

2. The <strong>Tender</strong> fees will be accepted only in <strong>for</strong>m <strong>of</strong> DD/A/c payee Cheque <strong>of</strong><br />

any Nationalized or Scheduled Bank <strong>of</strong> India payable in Silvassa.<br />

3. The EMD will be accepted in <strong>for</strong>m <strong>of</strong> FDR /A/c Payee Dem<strong>and</strong> Draft /<br />

Bankers Cheque or Bank Guarantee from any commercial banks in an<br />

acceptable <strong>for</strong>m payable at silvassa in favor <strong>of</strong> under signed.<br />

4. The EMD should not be <strong>for</strong>warded by cash.<br />

The tender inviting authority reserves the right to accept or reject any or all the<br />

tender to be received without assigning any reasons there<strong>of</strong>.<br />

In case bidder needs any clarification <strong>of</strong> if training required <strong>for</strong> participating in online<br />

tender, they can contact the following <strong>of</strong>fice. “(n) Code Solution –A Division, GNFC<br />

Ltd.” 403, GNFC info Tower, Bodakdev, Ahmedabad – 380 054, Gujarat (India) Email<br />

: nprocure@gnfc, Net Fax :+97 7926857321, Website : www.nprocure.com.<br />

<strong>Medical</strong> Superintendent<br />

Shri Vinoba Bhave Civil Hospital<br />

<strong>Dadra</strong> & Nagar Haveli<br />

Silvassa.


Copy to :-<br />

1) PS to Hon’ble Administrator, <strong>Dadra</strong> & Nagar Haveli, Silvassa <strong>for</strong> in<strong>for</strong>mation.<br />

2) P/A to Secretary (Health), <strong>Dadra</strong> & Nagar Haveli, Silvassa <strong>for</strong> in<strong>for</strong>mation<br />

3) All Heads <strong>of</strong> Office, <strong>Dadra</strong> & Nagar Haveli, Silvassa <strong>for</strong> in<strong>for</strong>mation & n.a.<br />

4) CPO, <strong>Dadra</strong> & Nagar Haveli, Silvassa <strong>for</strong> wide publicity in Newspaper.<br />

5) Director General, Indian Trade Journal, Kolkata <strong>for</strong> publication on Newspaper.<br />

6) NIC, <strong>Dadra</strong> & Nagar Haveli, Silvassa with a request to publish in Website.<br />

7) The Deputy Director (OL), <strong>Dadra</strong> & Nagar Haveli, Silvassa <strong>for</strong> translation in<br />

Hindi.<br />

8) Accounts Section, Shri VBCH, Silvassa <strong>for</strong> in<strong>for</strong>mation<br />

9) Central Store, Shri VBCH, Silvassa <strong>for</strong> In<strong>for</strong>mation.<br />

<strong>Medical</strong> Superintendent<br />

Shri Vinoba Bhave Civil Hospital<br />

<strong>Dadra</strong> & Nagar Haveli<br />

Silvassa.


U.T. ADMINISTRATION OF DADRA & NAGAR HAVELI,<br />

OFFICE OF THE MEDICAL SUPERINTENDENT,<br />

SHRI VINOBA BHAVE CIVIL HOSPITAL,<br />

SILVASSA<br />

Terms <strong>and</strong> Conditions <strong>for</strong> the “<strong>Purchase</strong> <strong>of</strong> <strong>Medical</strong> <strong>Equipments</strong>” <strong>for</strong><br />

Shri Vinoba Bhave Civil Hospital, <strong>Dadra</strong> & Nagar Haveli, Silvassa.<br />

� Instructions to Bidders :<br />

1) The rate should be quoted in the prescribed <strong>for</strong>m given by the<br />

department; the rate should be valid upto One Year from the<br />

date <strong>of</strong> tenderization.<br />

2) All/Taxes/Duties/Royalties Charges payable on the sales/transport<br />

etc. within <strong>and</strong>/or outside the state shall be payable by the<br />

supplier.<br />

3) Where specifications/make/manufacture is not specified by this<br />

<strong>of</strong>fice, the rates should be quoted only <strong>for</strong> the 1 st class <strong>and</strong><br />

st<strong>and</strong>ard quality only.<br />

4) The tenderer should specify the name <strong>of</strong> the manufacturer <strong>and</strong><br />

complete specification <strong>for</strong> the items quoted to be submitted in<br />

the Technical Bid.<br />

5) The decision <strong>of</strong> the <strong>Tender</strong> Inviting Officer <strong>for</strong><br />

acceptance/rejection <strong>of</strong> any articles supplied including the<br />

decision <strong>for</strong> equivalent specifications, st<strong>and</strong>ard <strong>and</strong> quality etc. <strong>of</strong><br />

articles shall be final.<br />

6) The <strong>Tender</strong>er should enclose along with tender the Earnest<br />

Money Deposit in <strong>for</strong>m <strong>of</strong> Fix Deposit Receipt/Account Payee<br />

Dem<strong>and</strong> Draft/Banker’s Cheque or Bank Guarantee from any <strong>of</strong><br />

the Commercial Banks in an acceptable <strong>for</strong>m payable at Silvassa<br />

in favour <strong>of</strong> <strong>Medical</strong> Superintendent, Shri Vinoba Bhave Civil<br />

Hospital, Silvassa. The EMD should not be <strong>for</strong>warded by Cash.


<strong>Tender</strong> received without Earnest Money Deposit will be summarily<br />

rejected.<br />

7) (a) The successful tenderer will have to pay within 10 days from<br />

the date <strong>of</strong> dem<strong>and</strong>, an amount equal to 10% <strong>of</strong> the total value <strong>of</strong><br />

articles, which may be ordered, as the amount <strong>of</strong> security deposit.<br />

(b) Non receipt <strong>of</strong> Security Deposit within stipulated time will<br />

result in automatic cancellation <strong>of</strong> the order <strong>for</strong> supply without<br />

any intimation.<br />

(c) However in case if any articles are received <strong>for</strong> which the<br />

Security Deposit may not have been deposited, the full Security<br />

Deposit as may be due from the supplier will be recovered from<br />

the bill(s) <strong>for</strong> such articles.<br />

8) The amount <strong>of</strong> Earnest Money paid by the successful <strong>Tender</strong>er(s)<br />

will be adjusted against the amount <strong>of</strong> Security Deposit to be paid<br />

by the successful tenderer(s) as per condition No.07 above.<br />

9) The tender should be neatly typed or h<strong>and</strong> written only on letter<br />

head carries the name <strong>of</strong> supplier <strong>and</strong> the signature <strong>of</strong> the<br />

tenderer. No overwriting, correction or erasures will be<br />

considered.<br />

10) All bills should be in TRIPLICATE <strong>and</strong> should invariably mention the<br />

number <strong>and</strong> date <strong>of</strong> supply order.<br />

11) All bills <strong>for</strong> amount above `.5000/- should be pre-receipted on a<br />

Revenue Stamp <strong>of</strong> proper value. Bills <strong>for</strong> amount exceeding<br />

`.5000/- not pre-receipted on Revenue Stamp <strong>of</strong> proper value will<br />

not be accepted <strong>for</strong> payment.<br />

12) Each bill in which Sales Tax is charged must contain the following<br />

certificates on the body <strong>of</strong> the bill: “CERTIFIED” that the goods on<br />

which Sales Tax has been charged have not been exempted under<br />

the Central Sale Tax Act or the Rules made there under <strong>and</strong> the<br />

amount charged on account <strong>of</strong> Sales Tax on these goods is not<br />

more than what is payable under the provisions <strong>of</strong> relevant Act or<br />

Rules made there under”.


13) The <strong>Tender</strong>s shall be submitted in two-bid system, wherein the<br />

Technical bid <strong>and</strong> Commercial Bid is to be filled in<br />

www.nprocure.com <strong>and</strong> the EMD <strong>and</strong> <strong>Tender</strong> Fee has to be<br />

submitted in <strong>Tender</strong> Box along with a covering letter. The<br />

envelope should be super scribing on the envelope as “Sealed<br />

Cover <strong>of</strong> Bid- <strong>Purchase</strong> <strong>of</strong> <strong>Medical</strong> <strong>Equipments</strong> <strong>for</strong> Shri Vinoba<br />

Bhave Civil Hospital”. The EMD <strong>and</strong> <strong>Tender</strong> Fees should be<br />

enclosed with BID only. The last date <strong>of</strong> submission will be<br />

10.09.2012 upto 11.00 hours.<br />

14) The right to accept or reject without assigning any reasons or all<br />

tenders in part or whole is reserved with the <strong>Tender</strong> Inviting<br />

Officer <strong>and</strong> his decision(s) on all matters relating to acceptance or<br />

rejection <strong>of</strong> the tenders as a whole or in part will be final <strong>and</strong><br />

binding to all.<br />

15) If the tenderer whose tender is accepted, fails to execute the<br />

supply order within stipulated time the Earnest Money Deposit <strong>of</strong><br />

such tenders will st<strong>and</strong> <strong>for</strong>feited to the Government.<br />

16) In case, the supplier does not execute the supply order placed<br />

with him, the EMD <strong>of</strong> the supplier will be <strong>for</strong>feited to the<br />

Government <strong>and</strong> the contract <strong>for</strong> the supply shall terminated with<br />

no further liabilities on either party to the contract.<br />

17) No separate agreement will be required to be signed by the<br />

successful tender(s) <strong>for</strong> the purpose <strong>of</strong> this contract <strong>for</strong> supply.<br />

Rates tendered/<strong>of</strong>fered in response to the concerned <strong>Tender</strong><br />

<strong>Notice</strong> shall be considered as acceptance <strong>of</strong> all above terms <strong>and</strong><br />

conditions <strong>for</strong> supply <strong>for</strong> all legal purpose.<br />

18) The tender will be accepted during working hours upto 10.09.2012<br />

at 11.00 hours <strong>and</strong> will open on the same day if possible in the<br />

<strong>of</strong>fice <strong>of</strong> the <strong>Medical</strong> Superintendent, Shri Vinoba Bhave Civil<br />

Hospital, Silvassa.


� Conditions <strong>of</strong> Contract :<br />

1) The rate(s) quoted should be strictly <strong>for</strong> free delivery at FOR<br />

Silvassa <strong>and</strong> will be valid <strong>and</strong> operative <strong>for</strong> supply orders issued<br />

within one year from the date <strong>of</strong> invitation <strong>of</strong> tenders.<br />

2) Orders once placed should be delivered within the given time<br />

period <strong>and</strong> item should be door delivered.<br />

3) No extra charge <strong>for</strong> packing, <strong>for</strong>warding <strong>and</strong> insurance etc. will be<br />

paid on the rates quoted.<br />

4) The rates should be quoted only <strong>for</strong> the items specified in the list<br />

<strong>of</strong> requirement <strong>and</strong> should be <strong>for</strong> the items <strong>of</strong> given special<br />

make/manufacture.<br />

5) Rates quoted <strong>for</strong> items other than the required<br />

specification/make/manufacture will not be considered.<br />

6) The amount <strong>of</strong> Earnest Money paid by the tenderer(s) whose<br />

tenders are not accepted will be refunded to them by cheque or<br />

Dem<strong>and</strong> Draft (as may be convenient to the <strong>Tender</strong> Inviting<br />

Officer if the amount is above `.200/-) drawn on any branch <strong>of</strong><br />

State <strong>of</strong> India or its subsidiary Commercial Bank. Where this mode<br />

<strong>of</strong> payment is not possible the amount will be refunded at the cost<br />

<strong>of</strong> the tenderer.<br />

7) Only on satisfactory completion <strong>of</strong> the supply order <strong>for</strong> <strong>and</strong> on<br />

payment <strong>of</strong> all bills <strong>of</strong> the supplier, as to be admitted <strong>for</strong> payment,<br />

the amount <strong>of</strong> Security Deposit/Earnest Money will be refunded<br />

after expiry <strong>of</strong> guarantee/warranty period, if any, or any such<br />

date/period as may be mutually agreed upon.<br />

8) The tender inviting <strong>of</strong>ficer will consider extension <strong>of</strong> time <strong>for</strong><br />

remitting the Security Deposit as dem<strong>and</strong>ed. However, in case <strong>of</strong><br />

denial to consider such extension the supplier is bound to abide<br />

by the limit given <strong>and</strong> liable to make good <strong>for</strong> the loss made to the<br />

Government on account <strong>of</strong> his failure to abide by the time limit.


9) Railway Receipt or other transport document should be drawn in<br />

the favor <strong>of</strong> Officer Inviting tender.<br />

10) Railway Receipt or other transport document should not be send<br />

by VPP or through any Bank as this being a Government Office it is<br />

not possible to clear cash dem<strong>and</strong>s <strong>of</strong> Post Office/Bank <strong>for</strong><br />

delivery <strong>of</strong> RR or other transport documents unless we have<br />

agreed to it as special arrangement.<br />

11) The supplies, materials etc. <strong>of</strong> inferior quality st<strong>and</strong>ard or <strong>of</strong><br />

different specifications, br<strong>and</strong>, manufacturer etc other than that<br />

ordered specified <strong>and</strong>/or incomplete or broken articles will not be<br />

accepted. The supplier has to replace the same at his own cost<br />

<strong>and</strong> risk. Intimation <strong>of</strong> non-acceptance <strong>of</strong> any materials etc will be<br />

sent to the supplier within 10 days from the date <strong>of</strong> receipt <strong>of</strong> the<br />

stores <strong>and</strong> the same will be returned to the supplier at his own<br />

cost <strong>and</strong> risk, if he so desires <strong>and</strong> intimates accordingly within 15<br />

days from the date <strong>of</strong> dispatch <strong>of</strong> intimation <strong>of</strong> the nonacceptance.<br />

However, if no communication is received within 15<br />

days from the date <strong>of</strong> communication the tender Inviting Officer<br />

will not be responsible <strong>for</strong> any damages, loss etc. <strong>of</strong> such rejected<br />

articles.<br />

12) In case <strong>of</strong> failure to replace the accepted <strong>and</strong> rejected articles<br />

from the supplies made, as mentioned in the conditions the loss<br />

undergone by the Government will be recovered from the<br />

suppliers Security Deposit/Earnest Money or payment due <strong>of</strong> any<br />

bill(s) to the extend required.<br />

13) In case <strong>of</strong> failure to supply the store, materials etc. ordered <strong>for</strong>, as<br />

per conditions <strong>and</strong> within the stipulated time, the name articles<br />

will be obtained from the tenderer who <strong>of</strong>fered next higher rates<br />

or from any other sources, as may be decided by the tender<br />

inviting Officer <strong>and</strong> the loss to the Government on account <strong>of</strong> such<br />

purchases(s) shall be recovered from the <strong>for</strong>mer suppliers Security<br />

Deposit/Earnest Money or bills payable. The suppliers shall have<br />

no right to dispute with such procedure.


14) Extension <strong>of</strong> time limit <strong>for</strong> supplies shall be considered by the<br />

<strong>Tender</strong> Inviting Officer. The extension so granted may be with levy<br />

<strong>of</strong> compensation <strong>for</strong> delay in execution <strong>of</strong> supply order up to 5%<br />

<strong>of</strong> the cost <strong>of</strong> supplies ordered <strong>for</strong> at the discretion <strong>of</strong> the<br />

authority competent to grant extension <strong>of</strong> time limit provided<br />

such request is made well in time, depending upon the<br />

circumstances <strong>and</strong> such decision in the matter will be final.<br />

15) Demurrage charges paid by the <strong>Tender</strong> Inviting Officer on account<br />

<strong>of</strong> delayed receipt <strong>of</strong> dispatch documents intimation will be<br />

recovered from the bills payable to the supplier.<br />

16) If at any time after the order <strong>for</strong> supply <strong>of</strong> materials the <strong>Tender</strong><br />

Inviting Officer shall <strong>for</strong> any reason whatsoever not require the<br />

whole or part <strong>of</strong> the quantity there<strong>of</strong> as specified in the order the<br />

<strong>Tender</strong> Inviting Officer shall give notice in writing <strong>of</strong> the fact to the<br />

supplier(s) who shall have to claim to any payment <strong>of</strong><br />

compensation what so ever on account <strong>of</strong> any pr<strong>of</strong>it or advantage<br />

which the supplier(s) might have derived from the supply <strong>of</strong><br />

articles in full, but which did not derive in consequence <strong>of</strong> the full<br />

quantity <strong>of</strong> articles not having been purchased, nor shall have any<br />

claim <strong>for</strong> compensation by reasons <strong>of</strong> any alterations having been<br />

made in the original instructions which shall invoice any<br />

curtailment <strong>of</strong> the supply originally contemplated.<br />

17) The Earnest Money(s)/Security Deposit(s) paid by the tender(s)<br />

earlier against any tender(s) or supply order(s) is/are not<br />

adjustable with Earnest Money or Security Deposit required by<br />

these conditions.<br />

18) The tenders/<strong>of</strong>fers received do not confirm with the terms <strong>and</strong><br />

conditions <strong>of</strong> this <strong>of</strong>fice will be summarily rejected. If any firm<br />

desires to consider exemption from payment <strong>of</strong> Earnest Money<br />

Deposit, certified copies <strong>of</strong> its Registration with D.G.S. & D. should<br />

be attached to their tenders.<br />

19) The items as mentioned in the list are the approximate estimates<br />

invited <strong>and</strong> actual purchase may more. Accordingly the successful<br />

tenderer has no right <strong>for</strong> any loss/damages with reference to


approximate requirement shown in tender <strong>and</strong> actual<br />

requirement.<br />

20) Supplier may ensure the goods at his own cost to safeguard the<br />

delivery <strong>of</strong> such goods dispatched by him to the consignee; the<br />

department will not be responsible <strong>for</strong> the damages or pilferage<br />

<strong>of</strong> goods during transit.<br />

21) The tenderer should attached copies <strong>of</strong> certificate <strong>of</strong><br />

• Experience in the field <strong>of</strong> selling <strong>of</strong> similar <strong>Medical</strong><br />

<strong>Equipments</strong>,<br />

• Pro<strong>of</strong> <strong>of</strong> fulfilling the norms <strong>of</strong> IS/ISO/CE specification if<br />

any,<br />

• Copy <strong>of</strong> dealership letter (as per Annexure 15) ,<br />

• License <strong>for</strong> import,<br />

• PAN No.,<br />

• Catalog <strong>of</strong> the item quoted etc.<br />

• Documentary evidence <strong>of</strong> their previous experience in<br />

carrying out similar supply <strong>and</strong> <strong>of</strong> their eligibility in support<br />

<strong>of</strong> their claim <strong>for</strong> consideration in the matter <strong>of</strong> award <strong>of</strong><br />

contract<br />

22) The manufacturing units who are placed in Silvassa are exempted<br />

<strong>for</strong> Earnest Money Deposit.<br />

23) Rates should be quoted in the <strong>for</strong>ms issued from the department<br />

<strong>and</strong> as per the requirement asked <strong>for</strong>. Rates quoted are <strong>for</strong> Shri<br />

Vinoba Bhave Civil Hospital, Silvassa.<br />

24) The tender should furnish a declaration regarding the<br />

Blacklisting/Debarring to participate in the Government tender on<br />

the letter head. If the in<strong>for</strong>mation provided found false the tender<br />

will be rejected <strong>and</strong> EMD shall be <strong>for</strong>feited.<br />

25) As <strong>and</strong> when necessary, any employee <strong>of</strong> this institution shall be<br />

given training <strong>for</strong> the use <strong>of</strong> equipments by the supplier at their<br />

cost.


26) The tender document shall be duly signed by the supplier.<br />

27) The <strong>Tender</strong>er has to submit the authorization letter from the<br />

principal manufacturing company as per the <strong>for</strong>mat prescribed in<br />

Annexure 14.<br />

28) Training <strong>of</strong> the <strong>Medical</strong> <strong>Equipments</strong> will be borne by the<br />

successful bidder as follows:<br />

a. Training <strong>for</strong> <strong>Medical</strong> Specialists at other centre under purview<br />

<strong>of</strong> a trained doctor outside Silvassa<br />

b. Training <strong>for</strong> <strong>Medical</strong> <strong>Equipments</strong> <strong>of</strong> Para-medical staff in Shri<br />

VBCH<br />

Signature & Designation <strong>of</strong><br />

<strong>Tender</strong> Inviting Officer…<br />

<strong>Medical</strong> Superintendent<br />

Shri Vinoba Bhave Civil Hospital<br />

<strong>Dadra</strong> & Nagar Haveli<br />

Silvassa.<br />

The above terms <strong>and</strong> conditions are accepted <strong>and</strong> are binding to me/us.<br />

Place: Signature <strong>of</strong> tenderer<br />

Dated: Name <strong>of</strong> tenderer with seal <strong>of</strong> the<br />

firm<br />

NOTE: Please return One Copy <strong>of</strong> these terms <strong>and</strong> conditions duly<br />

signed with seal <strong>of</strong> firm along with the tender.<br />

Place: Signature <strong>of</strong> tenderer<br />

Dated: Name <strong>of</strong> tenderer with seal <strong>of</strong> the<br />

firm


� Schedule <strong>of</strong> Requirements, Specifications <strong>and</strong> Allied<br />

Technical Details:<br />

The Specifications are mentioned on respective Annexure, the bidder has to<br />

fill the relevant annexure duly stamped <strong>and</strong> signed. Any deviation from the<br />

mentioned specification has to be mentioned in the Annexure-15.<br />

S.N Name <strong>of</strong> Equipment Mfg Company Preferred Qty Annexure<br />

Medicine<br />

1<br />

Temporary Pacemaker<br />

APC/Maquet/Medtronic/<br />

Biotronic<br />

5 1<br />

2 12 Lead ECG Machine GE/L&T/BPL/Alan 3 1<br />

3 Cardiac Stress Test Machine GE/Allengers/BPL 1 1<br />

4 External Defibrillator<br />

Nihon Kohden/Philips/<br />

GE/Mindray<br />

1 1<br />

5 Internal Defibrillator<br />

Meditronics/Biotronics/St<br />

Jude <strong>Medical</strong> /Boston Sci.<br />

1 1<br />

6 Holter with Ambulatory BP Vasomedical/Mortara/GE 1 1<br />

Pediatric & Neonatology<br />

Radiant Heat Warmer with<br />

1<br />

resuscitation unit<br />

2 LED Phototherapy<br />

Neotech/Bird<br />

Meditech/Meditrin/Fanem<br />

Neotech/Bird<br />

Meditech/Fanem<br />

9 2<br />

2 2<br />

3 Neonatal Ventilator Drager/GE/Philips 2 2<br />

4 3 Para Monitor Philips/GE/Draeger 1 2<br />

5<br />

Vein Vision device<br />

Dr Morepen/ Abott/Nice<br />

Neotech 1 2<br />

6 Electronic Weight Machine Zeal/SPI/ Accord 2 2<br />

7 CPAP Machine Fisher & Paykel/ Viasys/Fanem 2 2<br />

Ophthalmology<br />

Under VBCH<br />

1 Nd-Yag Laser Lumenis/Opto/Lynton 1 3<br />

2 Fundus Camera<br />

Under DBCP<br />

Biomedix/Leica/Karl Kaps/<br />

Karl Zeiss<br />

1 3<br />

1 Ophthalmic Microscope<br />

Karl Kaps/Karl Zeiss/Moller<br />

Wedel<br />

1 3<br />

2 Cryomachine Basco/Kohden/Leica 1 3<br />

3 Automated perimeter<br />

Topcon/Zeiss/Medmont/<br />

Humphrey/Appasamy<br />

1 3


S.N Name <strong>of</strong> Equipment Mfg Company Preferred Qty Annexure<br />

Dermatology<br />

1 IPL Laser with RF Derma India/Lumenis/Lynton 1 4<br />

2 Q-Switched Laser Derma India/Lumenis/Lynton 1 4<br />

3 Ultrasonic Face Lift Derma India/Krupa Mediscan 1 4<br />

4 Diode Laser Derma India/ Lumenis/ Lynton 1 4<br />

5 Digital Ionotophoresis Derma India/Krupa Mediscan 1 4<br />

Pathology<br />

1<br />

1<br />

Automated Coagulation<br />

Analyzer Span/Ark/Tulip/Tranasia<br />

1 5<br />

Fully Automated three part<br />

cell counter (18 para)<br />

Span/Ark/Tulip/Tranasia 1 5<br />

2 Binocular Microscope Nikon/Olympus/Zeiss 1 5<br />

3 Rotary Shaker Remi/St<strong>and</strong>ard Company 1 5<br />

4<br />

Four Door Vertical<br />

Refrigerator<br />

Automated System For<br />

Bluestar/Voltas 1 5<br />

5<br />

Identification And Antibiotic<br />

Susceptibility Testing <strong>of</strong><br />

Micro Organisms<br />

Biomerieux/Siemens/BD 1 5<br />

6 Automated Slide Stainer<br />

Thermo<br />

Scientific/Sakura/Neutec<br />

1 5<br />

7 Balance Weight Machine Metlar Tolado/Biomerieux 1 5<br />

Orthopedic<br />

1<br />

Battery Operated Drill<br />

Machine Microaire/Stryker/Synthes<br />

2 Hohman Variable retractors<br />

Kalelkar/Synthes/<br />

Teknomedical/Shushrut/Inor<br />

3 Bone Punches<br />

Kalelkar/Synthes/<br />

Teknomedical/Shushrut/Inor<br />

Kalellkar/<br />

4 Peripheral Nerve Locator Synthes/Teknomedical/<br />

Shushrut/Inor<br />

5<br />

Broken screw removal set<br />

(Hollow will) Synthes/Zimmer<br />

6<br />

7<br />

Minimally invasive& miniopen<br />

Discectomy <strong>and</strong>fusion<br />

system <strong>for</strong> both cervical <strong>and</strong><br />

thoracolumbar use.<br />

Meditronic/Teknomedical/<br />

SMPL/Inor<br />

RF Electrode <strong>for</strong> Mitek VAPR<br />

System Depuy Mitek<br />

1 6<br />

1<br />

1<br />

1<br />

1<br />

1<br />

5<br />

6<br />

6<br />

6<br />

6<br />

6<br />

6


S.N Name <strong>of</strong> Equipment Mfg Company Preferred Qty Annexure<br />

8 Flexible Reamer Manman 1 6<br />

9<br />

Wire Cutter tungsten tip<br />

with 2mm wire cutter Synthes/Zimmer/Inor<br />

1<br />

6<br />

10<br />

Sepectrum Instrument<br />

Shoulder Arthos<br />

Codman/Depuy<br />

Mitek/Kallelkar<br />

1<br />

6<br />

11 Monopolar Cautery Cords Galtron/St<strong>and</strong>ard Company 1 6<br />

12 Pencil Drill <strong>for</strong> H<strong>and</strong> Surgery Manman/Medtronic/Codman 1 6<br />

13 Centrifuge- 1800 rpm Remi/St<strong>and</strong>ard Company 1 6<br />

14 Bipolar Cautery Cords Galtron/St<strong>and</strong>ard Company 1 6<br />

15<br />

High definition Camera<br />

System with Xenon Light<br />

Source, 3 chip camera, light<br />

cable (thicker & longer),<br />

video imaging capturing<br />

device<br />

Physiotherapy<br />

1 Isokinetic System<br />

Karl Storz/<br />

Olympus/Maxer/Richard<br />

Wolf/Stryker 1 6<br />

Biotech/ BTE<br />

Technologies/Contrex 1 7<br />

2 Cryotherapy Unit Biotech/ Zimmer/Physiomed 1 7<br />

3 Multi CPM Unit DJO Global/Ormed 1 7<br />

4 Microwave Diathermy Biotech/ Physiomed 1 7<br />

5 Exercise Bike Proxomed/Scifit<br />

Biotech/ Alay Medins/Dev<br />

1 7<br />

6 Trapeze<br />

rehab<br />

Biotech/Alay medins/Dev<br />

1 7<br />

7 4 Channel TENS<br />

rehab/Bionics 1 7<br />

8 Bolsters Biotech/ Alay Medins 1 7<br />

9 Wobble Board Therab<strong>and</strong>/ Alay Medins 1 7<br />

10<br />

11<br />

High Frequency Chest Wall<br />

Oscillations- Adult &<br />

Pediatric<br />

Biotech/ Electromed/<br />

Respironics/ Philips 1 7<br />

Positive Expiratory Pressure-<br />

Adult & Pediatric Biotech/ Micro 1 7<br />

12 Therassist G5 Biotech/G5 1 7<br />

ENT<br />

1<br />

2<br />

Operating Microscope <strong>for</strong><br />

ENT, Plastic, Neuro <strong>and</strong><br />

spine.<br />

Nasal Endoscope adult 0<br />

degree 4mm<br />

Karl Zeiss/ Karl Kaps/ Olympus 1 8<br />

Olympus/Richard Wolf/Karl<br />

Storz/Maxer/Fujinon<br />

1 8


S.N Name <strong>of</strong> Equipment Mfg Company Preferred Qty Annexure<br />

3<br />

4<br />

5<br />

Nasal Endoscope pediatric 0<br />

degree 2.7mm<br />

Nasal Endoscope Adult 30<br />

degree 4 mm<br />

Nasal Endoscope Pediatric<br />

30 degree 2.7mm<br />

Laparoscopy & Urology<br />

1 Ureteroscope<br />

Neonatal/Pediatric<br />

2 Resectoscope<br />

Olympus/Richard Wolf/Karl<br />

Storz/Maxer/Fujinon<br />

Olympus/Richard Wolf/Karl<br />

Storz/Maxer/Fujinon<br />

Olympus/Richard Wolf/Karl<br />

Storz/Maxer/Fujinon<br />

1 8<br />

1 8<br />

1 8<br />

Karl Storz/Olympus/Fujinon/<br />

Richard Wolf 1 9<br />

Karl Storz/Olympus/Fujinon/<br />

Richard Wolf<br />

1<br />

9<br />

CSSD<br />

1 Drying Machine<br />

Tuttaneur/Steridium/Steelco/<br />

Taxus<br />

Steridium/Charmie/Memmert<br />

1 10<br />

2 Incubator<br />

/Medicarft Eqpt. 1 10<br />

3 ETO Taxus/Steridium/3M/PCI 1 10<br />

4 Auto Control Panel <strong>for</strong><br />

Autoclave Modi/Shrijee Surgical<br />

2 10<br />

General<br />

1 Fogging Machine<br />

Galtron/J&J/PCI/Radiant/<br />

Idealine/Skan/Aspee<br />

Omron/<br />

7 11<br />

3 Nebulizer<br />

Nulife/Morepen/Philips 10 11<br />

4 Fetal Doppler Teksonic/BPL/Galtron<br />

Nulife/Omron/Metco/Mehta<br />

4 11<br />

5 Needle Destroyer<br />

Surg.<br />

Brightlite/Supreme/Hira/<br />

20 11<br />

6 Suction Machine<br />

Galtron/SPI/An<strong>and</strong> 5 11<br />

7 Autoprocessor Prognosys/Chayyagraphics 1 11<br />

8 Solar Water Heater Plant Any St<strong>and</strong>ard Company 1 12<br />

9 Instruments Kalelkar/Inor/Adler/Uma 1 13<br />

The bidders can provide answers by placing the following codes to the right <strong>of</strong> each<br />

requirement description. Additional in<strong>for</strong>mation if necessary or helpful can be<br />

included as an attachment. (Format as an Annexure)<br />

Code Meaning<br />

Y Yes. Requirement is met completely<br />

N No. Cannot per<strong>for</strong>m this function <strong>and</strong> neither an enhancement is planned nor a<br />

modification is proposed.<br />

D Function is present but with slight modification. The deviation has to be mentioned in the<br />

deviation column.


� Price Schedules:<br />

S.N Name <strong>of</strong> Equipment Mfg Co.<br />

Medicine<br />

Temporary<br />

1<br />

Pacemaker<br />

2 12 Lead ECG Machine<br />

Cardiac Stress Test<br />

3<br />

Machine<br />

4 External Defibrillator<br />

5 Internal Defibrillator<br />

Holter with<br />

6<br />

Ambulatory BP<br />

Pediatric & Neonatology<br />

1<br />

Radiant Heat Warmer<br />

with resuscitation unit<br />

2 LED Phototherapy 2<br />

3 Neonatal Ventilator 2<br />

4 3 Para Monitor 1<br />

5 Vein Vision device 1<br />

6<br />

Electronic Weight<br />

Machine<br />

2<br />

7 CPAP Machine 2<br />

Ophthalmology<br />

Under VBCH<br />

1 Nd-Yag Laser 1<br />

2 Fundus Camera 1<br />

1<br />

Under DBCP<br />

Ophthalmic<br />

Microscope<br />

2 Cryomachine 1<br />

3 Automated Perimeter 1<br />

Dermatology<br />

1 IPL Laser with RF 1<br />

2 Q-Switched Laser 1<br />

3 Ultrasonic Face Lift 1<br />

Model<br />

Name Qty Unit Rate<br />

5<br />

3<br />

1<br />

1<br />

1<br />

1<br />

9<br />

1<br />

Total<br />

Amount


S.N Name <strong>of</strong> Equipment Mfg Co.<br />

Model<br />

Name<br />

Qty Unit Rate<br />

4 Diode Laser 1<br />

5 Digital Ionotophoresis 1<br />

Pathology<br />

1 Automated<br />

Coagulation Analyzer<br />

Fully Automated three<br />

1 part cell counter (18<br />

para)<br />

2 Binocular Microscope<br />

3 Rotary Shaker<br />

Four Door Vertical<br />

4<br />

Refrigerator<br />

Automated System<br />

For Identification And<br />

5 Antibiotic<br />

Susceptibility Testing<br />

<strong>of</strong> Micro Organisms<br />

Automated Slide<br />

6<br />

Stainer<br />

Balance Weight<br />

7<br />

Machine<br />

Orthopedic<br />

1<br />

Battery Operated Drill<br />

Machine<br />

1<br />

2<br />

Hohman Variable<br />

retractors<br />

1<br />

3 Bone Punches 1<br />

4 Nerve Locator 1<br />

5<br />

Broken screw removal<br />

set (Hollow will)<br />

Minimally invasive&<br />

mini-open Discectomy<br />

1<br />

6 <strong>and</strong>fusion system <strong>for</strong><br />

both cervical <strong>and</strong><br />

thoracolumbar use.<br />

1<br />

7<br />

RF Electrode <strong>for</strong> Mitek<br />

VAPR System<br />

5<br />

8 Flexible Reamer<br />

Wire Cutter tungsten<br />

1<br />

9 tip with 2mm wire<br />

cutter<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

Total<br />

Amount


S.N Name <strong>of</strong> Equipment Mfg Co.<br />

10<br />

11<br />

Sepectrum<br />

Instrument Shoulder<br />

Arthos<br />

Monopolar Cautery<br />

Cords<br />

12<br />

Pencil Drill <strong>for</strong> H<strong>and</strong><br />

Surgery<br />

1<br />

13 Centrifuge- 1800 rpm 1<br />

14 Bipolar Cautery Cords<br />

High definition<br />

Camera System with<br />

Xenon Light Source, 3<br />

1<br />

15 chip camera, light<br />

cable (thicker &<br />

longer) video imaging<br />

capturing device<br />

1<br />

Physiotherapy<br />

1 Isokinetic System 1<br />

2 Cryotherapy Unit 1<br />

3 Multi CPM Unit 1<br />

4 Microwave Diathermy 1<br />

5 Exercise Bike 1<br />

6 Trapeze 1<br />

7 4 Channel TENS 1<br />

8 Bolsters 1<br />

9 Wobble Board<br />

High Frequency Chest<br />

Wall Oscillations-<br />

1<br />

10 Adult & Pediatric<br />

Positive Expiratory<br />

Pressure- Adult &<br />

1<br />

11 Pediatric<br />

1<br />

12 Therassist G5 1<br />

ENT<br />

1<br />

Operating Microscope<br />

<strong>for</strong> ENT, Plastic, Neuro<br />

<strong>and</strong> spine.<br />

Model<br />

Name Qty Unit Rate<br />

1<br />

1<br />

1<br />

Total<br />

Amount


S.N Name <strong>of</strong> Equipment Mfg Co.<br />

2<br />

3<br />

4<br />

5<br />

Nasal Endoscope<br />

adult 0 degree 4mm<br />

Nasal Endoscope<br />

pediatric 0 degree<br />

2.7mm<br />

Nasal Endoscope<br />

Adult 30 degree 4mm<br />

Nasal Endoscope<br />

Pediatric 30 degree<br />

2.7mm<br />

Laparoscopy & Urology<br />

1 Ureteroscope<br />

Neonatal/Pediatric<br />

2 Resectoscope<br />

CSSD<br />

1 Drying Machine 1<br />

2 Incubator 1<br />

3 ETO 1<br />

4<br />

Auto Control Panel <strong>for</strong><br />

Autoclave<br />

2<br />

General<br />

1 Fogging Machine 7<br />

Model<br />

Name Qty Unit Rate<br />

3 Nebulizer 10<br />

4 Fetal Doppler 4<br />

5 Needle Destroyer 20<br />

6 Suction Machine 5<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

Total<br />

Amount<br />

7 Autoprocessor 1<br />

9<br />

Solar Water Heater<br />

Plant<br />

Please fill in Annexure – 16 <strong>and</strong> upload on website.<br />

10 Instruments Please fill in Annexure – 17 <strong>and</strong> upload on website.<br />

Note :<br />

1. The Rates quoted should be inclusive <strong>of</strong> all taxes.<br />

2. Kindly mention the rates <strong>of</strong> accessories separately in the financial bids <strong>for</strong> Future<br />

consideration on letter heads as annexure.


3. The Warranty/Guarantee <strong>for</strong> one year <strong>and</strong> free service clause to be clearly<br />

mentioned by the Manufacturer on their letter head. If the Authorized dealer is<br />

going to carry out the service then they have to furnish the authority letter given<br />

by the manufacturer to sale/service the specified product in this Territory.<br />

4. Rates <strong>for</strong> Annual Maintenance Contract <strong>of</strong> <strong>Medical</strong> equipment (both types Labor<br />

& Comprehensive) <strong>for</strong> seven year should be mentioned separately in the<br />

Financial Bid which will be considered <strong>for</strong> price evaluation. It should be clearly<br />

mentioned whether AMC /CMC will be done through company itself or its service<br />

franchise/dealers. In that case Manufacturing Company must give authority<br />

letter to such franchise/dealers on their letter head clearly mentioning free<br />

service period <strong>and</strong> AMC/CMC <strong>for</strong> period <strong>of</strong> three years.<br />

Type <strong>of</strong><br />

AMC<br />

1 st Year<br />

2 nd Year<br />

3 rd Year<br />

N year<br />

Labor AMC Comprehensive<br />

AMC<br />

Executed by<br />

(manufacturers/authorized<br />

service dealers) Name <strong>and</strong><br />

address to be specified here<br />

<strong>Medical</strong> Superintendent<br />

Signature <strong>of</strong> Suppliers/Dealers Shri Vinoba Bhave Civil Hospital<br />

With Rubber Stamp <strong>Dadra</strong> & Nagar Haveli<br />

Silvassa.


Annexure – 1<br />

Department <strong>of</strong> Medicine<br />

S.N Technical Specifications <strong>of</strong> Equipment Mfg. Co.<br />

Preferred<br />

1 Temporary Pacemaker<br />

APC/Maquet/<br />

Operating Modes VVI, VOO (over drive :200to350 Medtronic/<br />

ppm)<br />

Biotronic<br />

R-Wave Sensitivity Variable from 1mV to 20mV<br />

(2ms/13 ms triangular test<br />

pulse)<br />

scale accuracy : 1 to 10 mV<br />

±10% 10 to 20 mV ±20%<br />

Input Impedance<br />

Defibrillation<br />

8k ohm ± 10%<br />

Protection Suppression Diode<br />

R-Wave Filter High quality filter <strong>for</strong> acceptance<br />

<strong>of</strong> R-Wave specified 22Hz<br />

frequency components<br />

HF-Filter <strong>for</strong> suppression <strong>of</strong> high<br />

frequency Interference pulses<br />

Output Pulse Polarity: cathodic, capacitivity<br />

coupled<br />

<strong>for</strong>m: biphasic asymmetric<br />

width :1.5 ms ± 0.03ms<br />

Output Pulse stabilized output variables from<br />

Amplitude 5V to 15V<br />

scale accuracy ±5%<br />

Detection <strong>of</strong> Output Red LED flashes synchronously<br />

Pulse<br />

Stimulation<br />

to every stimulation pulse<br />

Frequency<br />

Run Away<br />

variable from 30to 180ppm<br />

scale accuracy: 40-100ppm±5%<br />

>100ppm ±10%<br />

Protection 200ppm±15ppm<br />

Refractory Period (0.375*Pulse interval )ms at<br />

nominal setting :313ms±5%<br />

Interference Input pulse sequence<br />

Recognition 4.5 Hz) cause the<br />

system to switch over to the<br />

asynchronous stimulation<br />

frequency


Battery Control Visual Indication<br />

9 Volt 1 no./AA battery (with<br />

backup system while changing<br />

Battery<br />

the batteries)<br />

60mm*115mm*20mm, plastic<br />

Dimension housing<br />

Weight 185g(incl. battery)<br />

Security sockets;1.8 to 2.3 mm<br />

diameter<br />

Connection <strong>of</strong> Leads<br />

2 12 Channel ECG Machine<br />

• It should have simultaneous 12 channel ECG recording<br />

with 12 lead simultaneous acquisitions.<br />

• It should have minimum 5 inch high resolution foldable<br />

screen.<br />

• QWERTY alphanumeric keyboard<br />

• Built in ECG parameters measurements <strong>and</strong><br />

interpretation<br />

• Print Mode: Presample / Real time Sample/Arrhythmia<br />

triggered sample• Capability <strong>of</strong> storing minimum 100<br />

ECGs<br />

• Should support external archiving i.e. USB drive <strong>for</strong><br />

virtually unlimited ECG data storage.<br />

• Built in rechargeable lithium ion battery<br />

• Communication interface: Ethernet, RS 232, USB<br />

• It should have circuit protection from<br />

defibrillator <strong>and</strong> pacemaker<br />

• It should have sensitivity from 2.5 to 20 AGC (mm/mV)<br />

with CMRR ≥ 100 dB.<br />

• Safety St<strong>and</strong>ard: IECI/CF<br />

• It should have a thermal printer to print A4 size Z fold<br />

or 210 mm roll papers.<br />

• The record speed range from 5 to 50 mm/sec<br />

• Integration with PC with s<strong>of</strong>tware to store <strong>and</strong> transmit<br />

the ECG recordings.<br />

St<strong>and</strong>ard Accessories:<br />

1. Patient cable 12 Lead: 1 no.<br />

2. Chest Electrode: 6 nos.<br />

3. Limb Electrode: 4 nos.<br />

4. Jelly Bottle: 1no.<br />

5. Paper Roll: 5 nos.<br />

6. Power Cord: 1 no.<br />

7. User Manual: 1 no.<br />

GE/L&T/BPL/<br />

Alan


3 Cardiac Stress test Machine<br />

1. System should acquire <strong>and</strong> analyze 12 leads.<br />

2. System should be able should run on Windows operating<br />

system <strong>and</strong> should be provided with the computer system<br />

with the following configuration: Pentium Core 2Duo or<br />

Dual core CPU with DVD, 19” Color monitor; 160 GB Hard<br />

drive, Mouse, Keyboard <strong>and</strong> UPS <strong>for</strong> the CPU.<br />

3. Signal acquisition <strong>and</strong> digitization from patient should be<br />

per<strong>for</strong>med at the patient itself <strong>for</strong> elimination <strong>of</strong><br />

environmental noise. It should have wireless patient<br />

module between patient <strong>and</strong> analyzer thus providing<br />

wireless transmission <strong>of</strong> patients ECG / remote patient<br />

preparation. The wireless module must have display <strong>for</strong><br />

ECG wave<strong>for</strong>m, electrode impedance check, low battery/<br />

lead fail display.<br />

4. Should provide st<strong>and</strong>ard Full Interpretation <strong>of</strong> Supine<br />

ECG with reasoning.<br />

5. Should have display <strong>of</strong> real time 12 lead diagnostic<br />

quality ECG wave<strong>for</strong>m, average complexes beat <strong>of</strong> all 12<br />

leads with superimposed color comparison along with<br />

digital value <strong>of</strong> ST level <strong>and</strong> slope. Display <strong>of</strong> enlarged<br />

complex <strong>and</strong> facility <strong>of</strong> dynamic lead selection <strong>for</strong><br />

maximum ST changes. The display <strong>of</strong> 1mm graph on the<br />

monitor should be similar to the graph on the recording<br />

paper.<br />

6. Automatic detection, display, Storage <strong>and</strong> review <strong>of</strong><br />

arrhythmia, Heart Rate, Double Product <strong>and</strong> METS. It<br />

should have online HR METs, <strong>and</strong> ST running trends<br />

available on the screen during exercise.<br />

7. Should have filters <strong>for</strong> line frequency <strong>and</strong> special filters<br />

to reduce noise <strong>and</strong> baseline artifacts without<br />

compromising the ECG frequency response.<br />

8. System should have full disclosure play back, review <strong>and</strong><br />

storage <strong>of</strong> patient ECG raw data <strong>for</strong> unlimited numbers<br />

depending upon size <strong>of</strong> the hard disk. The unit should have<br />

the ability to readjust the “J Point” in increments <strong>of</strong> 1 m<br />

sec <strong>and</strong> generate a new report from stored raw ECG data.<br />

9. System should provide multiple <strong>and</strong> customizable<br />

printing <strong>for</strong>mats as per user’s choice on A4 size high<br />

resolution thermal printer <strong>for</strong> online real time printings. It<br />

should also be possible to print reports on laser printer.<br />

Should be supplied along with the compatible laser printer.<br />

10. System must have ECG trigger output to interface with<br />

external automatic devices.<br />

11. Should be supplied with Heavy Duty Treadmill, with<br />

speed ranging from 0.5 to 12 mph <strong>and</strong> grade <strong>of</strong> 0 – 22%<br />

with suitable 3 KVA servo stabilizer. The treadmill should<br />

be US FDA approved OR CE certified.<br />

GE/Allengers/<br />

BPL/ Mortara


12. Should be supplied with Automatic Non-Invasive Blood<br />

Pressure Monitor, which can be programmed to take the<br />

blood pressure automatically with each stage, without any<br />

need to manually take the measurements. The Automatic<br />

NIBP Monitor should be fully compatible with the stress<br />

test system <strong>for</strong> bi-directional exchange <strong>of</strong> data. Automatic<br />

NIBP Monitor <strong>and</strong> the Stress Test System should also have<br />

facility <strong>of</strong> measuring <strong>and</strong> recording SpO2 (Pulse Oximetry)<br />

values, automatically with each stage.<br />

13. The Machine should be US FDA approved <strong>and</strong> CE<br />

marked.<br />

14. Buyback <strong>of</strong> existing Stress Test Machine <strong>of</strong> BPL Make<br />

Dynatran which is in working condition.<br />

4 Biphasic Defibrillator with AED pacing<br />

1. The defibrillator should be based on biphasic<br />

wave<strong>for</strong>m technology<br />

2. The machine should have facility <strong>for</strong> choosing energy<br />

manually from 2 – 360 J in Biphasic Truncated<br />

wave<strong>for</strong>m or up to 200J in Rectilinear Biphasic<br />

wave<strong>for</strong>m <strong>and</strong> provision <strong>of</strong> choosing an AED energy<br />

up to minimum 200 j.<br />

3. Charging time should be less than 10s <strong>for</strong> 200 J<br />

4. Should have facility <strong>for</strong> manual energy delivery thru<br />

external & internal paddles, synchronized cardioversion<br />

(through hard paddles) <strong>and</strong> automated<br />

external defibrillation (through pads).<br />

5. Should have built in external pacing facility (both<br />

dem<strong>and</strong> <strong>and</strong> non dem<strong>and</strong> modes).<br />

6. Should have color LCD/ TFT monitor display <strong>for</strong> clear<br />

view <strong>of</strong> the screen from distance.<br />

7. Should work both on 220 VAC <strong>and</strong> rechargeable built<br />

in battery.<br />

8. It should have LI-ON battery with battery indicator on<br />

the screen<br />

9. Should have a built in recorder minimum 50 mm.<br />

10. Should have optional facility <strong>of</strong> Masimo Pulse<br />

Oximetery<br />

11. Should be US FDA approved<br />

5 Internal/Implantable Defibrillator<br />

• it should provides single chamber rate adaptive<br />

bradycardia pacing support as well as tachyarrhythmia<br />

detection <strong>and</strong> therapy with maximum 30 joule energy.<br />

• It should have optional wireless remote home<br />

monitoring facility based on GPRS system<br />

• It should have a facility <strong>of</strong> ATP where a device delivers<br />

the ATP be<strong>for</strong>e charging <strong>for</strong> fast <strong>and</strong> stable right<br />

ventricular rates within VF zone<br />

Nihon<br />

Kohden/<br />

Philips/GE/<br />

Mindray<br />

Meditronics<br />

/Biotronics/<br />

St. Jude<br />

<strong>Medical</strong>/<br />

Boston Sci.


• It should be provided with PRO-MRI ICD Lead with 8F<br />

lead delivery System.<br />

• It should have three zones <strong>for</strong> programming <strong>of</strong><br />

appropriate therapy delivery system.<br />

• It should have service time <strong>of</strong> more than 7 years with<br />

programming <strong>of</strong> VVI 60ppm; 2.5V at 0.5 ms; RV 15%<br />

pacing; 700 Ω; quarterly shocks; Home Monitoring <strong>and</strong><br />

full HD on.<br />

6 Holter with Ambulatory BP<br />

Power Consumption: 1 aaa alkaline or rechargeable<br />

battery<br />

Dimensions: 66 x 59 x 17 mm<br />

Weight (excl. battery): 50g<br />

Sampling, A/D resolution: 1200Hz or 600Hz, 12 bit<br />

ECG storage: 150, 300 or 600 Hz on a st<strong>and</strong>ard MMC/SD<br />

memory card<br />

Storage Capacity: up to 96 hours <strong>of</strong> ECG (300 Hz, 3<br />

bipolar channels, 1GB memory card)<br />

Frequency Range: 0.05-100 Hz (-3 dB)<br />

Dynamic Range: 16 mVp-v<br />

DC <strong>of</strong>fset tolerance: ±300mV<br />

Input Impedance: 100MOhm<br />

ECG: 1,2,3,5 channels (7 leads)<br />

Data Transfer:<br />

Optical cable with USB plug<br />

Bluetooth<br />

SD/MMC card reader is needed <strong>for</strong> receiving data<br />

Con<strong>for</strong>mity Certificates: CE<br />

Ambulatory BP<br />

Measurement Method: Oscillometric<br />

Power Consumption:<br />

2AA Rechargeable or alkaline batteries<br />

4AA Rechargeable or alkaline batteries<br />

Dimensions: 98 x 69 x 29 mm & 124 x 82 x 33.5 mm<br />

Weight (excl. batteries) : 190g, 250g<br />

Measurement Range:<br />

Blood Pressure: 30-260 mmHg (4-35 Kpa)<br />

Pulse: 40-200 beat/minute<br />

Passive Accuracy: 3 mmHg or 2% <strong>of</strong> the measured value<br />

Data Transfer:<br />

Optical cable with USB plug<br />

Wireless Bluetooth<br />

Optical cable with serial/USB plug<br />

Storage Capacity: 600 measurements<br />

Con<strong>for</strong>mity Certificates: CE, FDA<br />

Validation: BHS, AAMI protocol<br />

Vasomedical<br />

/Mortara / GE


Annexure – 2<br />

Department <strong>of</strong> Pediatrics & Neonatology<br />

S.N Technical Specifications <strong>of</strong> Equipment Mfg. Co.<br />

Preferred<br />

1 Radiant Heat Warmer with resuscitation unit<br />

• Mobile newborn table with fixed height radiant warmer.<br />

• Antistatic castors, 2 with brakes.<br />

• Table surface with mattress with infant head/ shoulder<br />

support.<br />

• Mattress padding-foam density approximately: 25kg/m 3 Neotech/Bird<br />

Meditech/<br />

Meditrin/<br />

Fanem<br />

.<br />

• Mattress cover: removable with zipper, waterpro<strong>of</strong>,<br />

washable, resistant to cleaning with chlorine based solution<br />

<strong>and</strong> flame retardant.<br />

• warmer module should easily pivot @ 90 degree in either<br />

direction to facilitate x-ray without affecting thermal<br />

operation<br />

• Side boards transparent acrylic, drop down by single h<strong>and</strong><br />

action <strong>and</strong> lockable.<br />

• Lower shelf & Under table 2 storage drawers, IV Pole <strong>and</strong><br />

swivel trays <strong>for</strong> instrument<br />

• Warmer body fabrication should be in Stainless steel<br />

• Side rails allow <strong>for</strong> mounting <strong>of</strong> accessories.<br />

• Hood suspended above the table integrates heating element<br />

<strong>and</strong> overhead light.<br />

• Overhead light 2 x 50W halogen spot, with dimming function.<br />

• Heating element: Ceramic Heater with parabolic reflector<br />

<strong>and</strong> protected by metal grid.<br />

• Control unit allows air <strong>and</strong> skin temperature preset (LED<br />

indicator) <strong>and</strong> drives radiant heater output (servo & manual).<br />

• Integrated timer: 1-59min, with count-up <strong>and</strong> count-down<br />

feature.<br />

• Temperature range, skin: 34-38ºC (user pre-settable).<br />

• Monitoring <strong>of</strong> skin temperature by means <strong>of</strong> sensor, range:<br />

30-42ºC.<br />

• Heater output & display: 0-100% in increments <strong>of</strong> 5%.<br />

• It should have automatic pre warm mode that allows long<br />

term controlled warming <strong>of</strong> mattress<br />

• Four functionally different modes :- Automatic pre warm,<br />

manual, Skin & Air controlled to maintain optimum thermal<br />

environment<br />

• Control unit: audiovisual alarms according to timer <strong>and</strong>


temperature presets avoiding overheating.<br />

• Displays reports systems errors, heater failure, sensor failure<br />

on LCD.<br />

• Unit should have On Board Calibration Facility with feather<br />

touch keys<br />

• It should have inbuilt optimal resuscitation with safe &<br />

controlled peak inspiratory pressure (PIP) & consistent &<br />

precise PEEP.<br />

• It should be capable to upgrade with infant weighing scale as<br />

well as motorized height adjustment.<br />

• Power requirement: 220V/ 50Hz.<br />

• Power consumption: 800W.<br />

• Device is produced by ISO 13485:2003 certified<br />

manufacturer (certificate to be submitted).<br />

• Infant Warmer should be safety certified according to CE<br />

93/42 / FDA 510k (certificate to be submitted. Manufacturer<br />

should have supplied CE /FDA 510k certified product at least<br />

24 months prior to submission).<br />

• Infant Warmer should be designed & tested as per IEC 601-<br />

1:1998 + A1:1991 + A2:1995, IEC 601-2-21:1994 <strong>and</strong> IEC<br />

60601-1-2, 2001 (Test certificates from NABL approved<br />

Government laboratory should be submitted).<br />

• Buyback <strong>of</strong> a. Wall Mounted Radiant Heat Warmer, Meditrin<br />

Make – in Working Condition (5 Nos.), b. Radiant Heat<br />

Warmer, Delta Make – in working condition (1 nos.)<br />

Should be Supplied with:<br />

a) Oxygen Regulator with Hose pipe, place to keep Oxygen<br />

cylinder, Flow meter, Humidifier bottle with tubings<br />

b) Manual Resuscitation Silicon Autoclavable bag with neonate<br />

& infant Mask<br />

c) Inline manometer to monitor pressure <strong>of</strong> oxygen given by<br />

resuscitation bag<br />

d) Electrically operated suction unit provides safe settable<br />

suction required <strong>for</strong> neonates<br />

e) Laryngoscopes with blades Malleable stylet<br />

f) ET tubes disposable with slip joints sizes: 2.5, 3.0, 3.5 & 4 mm<br />

2 LED Phototherapy<br />

OVERHEAD SOURCE UNIT (Blue LED)<br />

It should have BLUE LEDs which do not emit light in the<br />

ultraviolet (UV) range - reducing the potential risk <strong>of</strong> skin<br />

damage<br />

Also it should not emit light in the infrared radiation (IR)<br />

range - reducing the potential risk <strong>of</strong> fluid loss<br />

It should deliver irradiance > 30 µW/cm2/nm) at distance <strong>of</strong><br />

15” from source to patient<br />

Neotech /Bird<br />

Meditech/<br />

Fanem


LEDs should eliminate costly <strong>and</strong> time-consuming bulb<br />

replacements by providing up to 20,000 hours <strong>of</strong> use<br />

It should be Totally cool therapy. Should not generate heat<br />

Power consumption should not be more than 40 Watts<br />

It should have st<strong>and</strong> movable on castors<br />

It should have angle adjustment facility to use with Radiant<br />

Warmer<br />

It should have Digital time totalizer on LCD with backlit<br />

LED Phototherapy should be safety certified according CE<br />

93/42, FDA 510k<br />

St<strong>and</strong> fabrication should be in Stainless steel<br />

Phototherapy Should be tested as per IEC 60601-1-2, 2001,<br />

2nd Edition<br />

IEC 601-1:1988 +A1:1991 +A2:1995<br />

IEC 60601-2-50 2000<br />

Luminance : ≥35000 Lux<br />

Color Temperature: 3500-5000 K<br />

Spot Diameter: 150-300 (mm)<br />

Illumination Depth: ≥800 (mm)<br />

Light –adjusting Mode: Eight grade dimmer system<br />

Temperature at Surgeon’s Head: ≤1%<br />

Power Supply: 220 Volts, 50 Hz.<br />

CRI (Ra) : ≥97%<br />

3 Neonatal Ventilator<br />

• Advanced microprocessor based continuous flow , pressure<br />

limited, time cycled ventilator <strong>for</strong> very low body weight<br />

infants (premature, newborns) upgradeable <strong>for</strong> additional<br />

functions<br />

• Should be an upgradeable design with s<strong>of</strong>tware/hardware<br />

upgradeability <strong>for</strong> new/ future functions with inbuilt graphic<br />

screen<br />

• The ventilator should have ventilation modes as below:<br />

o IPPV / IMV<br />

o Assist Control<br />

o SIMV<br />

o CPAP<br />

o HFOV<br />

o PSV<br />

o VG<br />

• Should have settings <strong>for</strong> :<br />

Peak Inspiratory Pressure 10 - 80 cmH2O<br />

Flow independent PEEP 0 – 15 cmH2O<br />

Inspiratory Time 0.1 – 2 sec<br />

Expiratory Time 0.2 – 30 sec<br />

Draeger/ GE<br />

/Philips


Maximum Rate (based on Insp. Time <strong>and</strong><br />

exp. Time)<br />

200 bpm<br />

Inspiratory flow 1 – 30 lpm<br />

Base flow (VIVE) 1 – 30 lpm<br />

Slope control 0 - 2 sec.<br />

FiO2 21 - 100%<br />

• Should have real time monitoring at Y-piece <strong>of</strong>:<br />

o Pressure - Peak, Plateau, Mean, CPAP/PEEP<br />

o Expired Tidal Volume (Monitored), Expired Minute<br />

Volume, leakage in %<br />

o Frequency/ Rate - Set (Inspiratory), Spontaneous MV<br />

in %, total , I:E ratio<br />

o FiO2<br />

o Lung Mechanics - Resistance, Compliance , C20/C,<br />

Time constant Tc, RVR<br />

• Should have automatic alarm settings <strong>for</strong> all alarms. MV<br />

alarm can be manually adjusted along with alarms <strong>for</strong> :<br />

o Disconnection<br />

o Tube blocked<br />

o Ventilation hose kinked<br />

o High/low Pressure<br />

o High/low Minute Volume<br />

o High Rate<br />

o High Tidal Volume<br />

o Apnoea / apnoea alarm time<br />

o High/low O2 % (automatic settings)<br />

o Oxygen line failure<br />

o Compressed air failure<br />

o Total electronic failure (with error code)<br />

Pressure Support/ Volume Guarantee<br />

• It should be possible to give leakage adapted pressure<br />

support to spontaneously breathing patients with a set<br />

volume guarantee.<br />

• Volume guarantee should be regulated with lowest<br />

possible airway pressure within a set PIP.<br />

<strong>Medical</strong> Air Compressor<br />

• Dedicated <strong>Medical</strong> Air Compressor to provide quality air as<br />

per ISO st<strong>and</strong>ard<br />

• Snap fit with the ventilator machine<br />

• Peak flow should be minimum 180LPM


• It should be <strong>of</strong> original company whose ventilator machine<br />

is quoted.<br />

• It should be CE certified.<br />

Nasal CPAP ventilation<br />

• The nasal CPAP unit should be self contained with head<br />

strap, hood, nasal prongs, fixing unit.<br />

• Should be possible to field upgrade the same if required<br />

HFOV<br />

• It should be possible to combine HFOV as below :<br />

o IPPV + HFOV<br />

o CPAP + HFOV.<br />

• The HFOV function should be integrated in same machine<br />

<strong>and</strong> NOT external facility.<br />

• The HFOV function should control :<br />

o Frequency in Hz : 5 – 20 Hz.<br />

o Amplitude control : 0 – 100%.<br />

• It should be possible to use HFOV WITHOUT disconnecting<br />

the patient by simply switching ON/OFF in the same<br />

machine .If HFOV is <strong>of</strong>fered, separate patient tubings <strong>for</strong><br />

same to be <strong>of</strong>fered.<br />

• Should measure parameters in HFOV such as DCO2, VtHF<br />

(tidal volume in HFOV), MVim (MV in IMV strokes in<br />

inspiration), VTim (MV in IMV strokes in expiration)<br />

• Scope <strong>of</strong> supply should include<br />

o Basic Unit ( 220 - 240 V)<br />

o Modular corrosion free Trolley<br />

o Silicon corrugated Hose set<br />

o High frequency hose set (Autoclavable)<br />

o Servo controlled humidifier with reusable chamber<br />

o Flow sensor – Minimum 10 pcs.<br />

o O2 cell<br />

o Nebuliser<br />

o Oxygen connecting Hose<br />

o Air connecting Hose<br />

o Hinged arm <strong>for</strong> rail (Support <strong>for</strong> patient circuit)<br />

o Neonatal test lung<br />

o Instruction Manual<br />

o <strong>Medical</strong> Air Compressor<br />

• Quality St<strong>and</strong>ards <strong>and</strong> Support requirements –<br />

o The <strong>of</strong>fered unit should have CE certificate<br />

o The unit also should have FDA certification<br />

o The unit should comply with relevant IEC<br />

Certification<br />

o Indian subsidiary/ dealer should have nationwide


network, support <strong>of</strong>fices <strong>and</strong> must be also ISO<br />

9001 certified.<br />

4 3 Para Monitor<br />

1. Should be suitable <strong>for</strong> adult, paediatric neonatal patients<br />

monitoring.<br />

2. Should have minimum 8 channels <strong>of</strong> wave<strong>for</strong>ms with 15’’<br />

TFT-LCD colour integrated touch screen display (resolution<br />

min 1024*768). Should display 11 wave<strong>for</strong>ms will all ECG<br />

wave<strong>for</strong>ms.<br />

3. Should monitor ECG, Respiration, NIBP, SpO2, Dual<br />

Temperature,Dual & Dual IBP as st<strong>and</strong>ard<br />

4. Should have ST analysis, Arrhythmia detection as st<strong>and</strong>ard in<br />

every monitor<br />

5. Should have Drug Dose Calculation <strong>and</strong> OxyCRG as st<strong>and</strong>ard<br />

in every monitor<br />

6. Should have pacer spike detection as st<strong>and</strong>ard<br />

7. Defib <strong>and</strong> ESU protection should be present<br />

8. Should have monitoring, surgery <strong>and</strong> diagnostic mode <strong>of</strong><br />

monitoring<br />

9. Arrhythmia monitoring <strong>for</strong> Asystole, Vfib/Vtac, VT>2,<br />

Couplet, Bigeminy, Trigeminy, R on T, PVC, Tachy, Brady,<br />

Missed Beats, IRR, PNC, Vbrady.<br />

10. Monitor access should be with Touch screen <strong>and</strong> rotary<br />

knob.<br />

11. Fast access key should be provided <strong>for</strong> quick function.<br />

12. 120 hrs <strong>of</strong> trend <strong>and</strong> 60 events with wave<strong>for</strong>m as st<strong>and</strong>ard in<br />

all monitors<br />

13. Color or position <strong>of</strong> wave<strong>for</strong>ms or parameters should be able<br />

to be adjusted based on users preferences. Big font on<br />

screen <strong>for</strong>mat should be present.<br />

14. Nurse call, Analog output, VGA output port should be<br />

st<strong>and</strong>ard in every monitor.<br />

15. Monitor should have USB port <strong>for</strong> s<strong>of</strong>tware upgrade<br />

16. Anti left lock facility should be possible <strong>for</strong> better hospital<br />

asset management<br />

17. Should have inbuilt three channel recorder as st<strong>and</strong>ard in<br />

every monitor<br />

18. Should have 120 hrs (typically) <strong>of</strong> battery backup typically as<br />

st<strong>and</strong>ard in every monitor<br />

19. Inbuilt three channel recorder as st<strong>and</strong>ard with every<br />

monitor as st<strong>and</strong>ar<br />

20. Should be CE approved <strong>and</strong> comply to European Directive<br />

93/42/EEC <strong>for</strong> both Monitor <strong>and</strong> s<strong>of</strong>tware to control<br />

physiologic monitoring systems.<br />

Should have following parameters<br />

Philips/GE/<br />

Draeger


ECG<br />

− Monitor should have capability <strong>for</strong> display upto 7Lead .<br />

− ST Analysis<br />

− Wave<strong>for</strong>m Freeze option with review <strong>of</strong> 120 sec<br />

RESPIRATION<br />

− Through impedance pneumography method or EtCO2<br />

SpO2<br />

− Should display digital value <strong>and</strong> Plethysmograph<br />

NIBP<br />

− By oscillometric principle <strong>of</strong> measurement.<br />

− Should display Systolic, diastolic, mean pressure in<br />

large easy to read display<br />

Dual Temperature – core <strong>and</strong> skin<br />

Dual IBP – Should include Starter kit <strong>and</strong> simultaneous<br />

monitoring <strong>of</strong> dual temp <strong>and</strong> dual IBP should be possible<br />

Manufacturer should have ISO 9001, ISO 13485 <strong>and</strong> ISO 14001<br />

certification<br />

Quoted product should be CE certified.<br />

Scope <strong>of</strong> supply must include:<br />

− Basic unit with ECG, Resp, SpO2, Dual Temp, NIBP, Dual IBP,<br />

Inbuilt battery, Inbuilt three channel recorder -<br />

− 3 <strong>and</strong> 5 lead ECG Cable – 1 no each per monitor<br />

− ECG disposable electrodes – 30 nos per monitor<br />

− SpO2 finger sensor <strong>and</strong> extension cable – 1 no<br />

− Skin temperature probe – 1 no<br />

− Rectal temperature probe – 1 no<br />

− NIBP Hose with Adult & child cuff – 1 no r<br />

− Should be supplied with intermediate IBP cable <strong>and</strong><br />

transducer – 1no<br />

− Paper rolls- 4no<br />

− Instruction <strong>for</strong> Use per monitor<br />

− Manual per monitor<br />

5 Vein Vision Device<br />

• It should be designed specifically <strong>for</strong> Neonates & Infant<br />

patient.<br />

• It should provide complete solution <strong>for</strong> finding the artery &<br />

also assist in the diagnosis <strong>of</strong> pneumothorax.<br />

• It should be micro computer controlled system.<br />

• It should be cool white LED light system so that heat does<br />

not interfere in procedures. The light intensity should be<br />

variable 0 to 100%<br />

• It should be supplied with long fibre optic cable approx. 1<br />

mtr length with optical cable lock facility.<br />

• It should be compact, light & user friendly system mounted<br />

on sturdy trolley from same manufacturer.<br />

Dr Morepen /<br />

Abott/Nice<br />

Neotech


• It should display parameters like % <strong>of</strong> intensity, usage hours<br />

& timer.<br />

• It should have alarm indications like fan fail, temperature<br />

sensor fail, light source over temperature etc etc.<br />

• The manufacturer should be ISO 9001: 2008, ISO 13485:<br />

3003& CE approved Co only & all necessary documents<br />

should be enclosed in the bid.<br />

6 Electronic Weight Machine<br />

Capacity = 35Kg<br />

Accuracy= +/- 5g<br />

High Bright LED Display<br />

Kg to Lbs Conversion facility<br />

Facility to weigh accurate weight <strong>of</strong> crying / active baby<br />

Baby Pan size = 22 X 14”<br />

Plat<strong>for</strong>m size = 12 X 12”<br />

Detached Plat<strong>for</strong>m <strong>and</strong> Console<br />

Operating Voltages = 200V to 260V A<br />

7 CPAP Machine<br />

• It should be relatively quiet, mobile <strong>and</strong> sturdy, simple to<br />

operate.<br />

• It should have facilities to provide CPAP from 3-10 cm <strong>of</strong> H2O<br />

• It should also have facility to deliver Bubbling CPAP.<br />

• It should have facility to deliver manual IPPR.<br />

• It should have inbuilt Air Source.<br />

• It should have inbuilt Blender <strong>of</strong> Air & Oxygen <strong>for</strong> 21% - 100%<br />

FiO2 Adjustment<br />

• It should have servo heated wire humidifier <strong>for</strong> warming gas<br />

delivered to patient.<br />

• Humidifier should have separate LED display <strong>for</strong> chamber<br />

temperature <strong>and</strong> proximal end temperature.<br />

• Auto cleavable, transparent, unbreakable Humidifier<br />

chamber.<br />

• It should have Digital <strong>and</strong> Analog display <strong>of</strong> delivered<br />

pressure measured at proximal end.<br />

• High <strong>and</strong> Low CPAP Level settings with alarm.<br />

• Safety pressure relief in event <strong>of</strong> accidental over pressure.<br />

• Patient Interface System like Head Cap, Nasal Cannula should<br />

be provided.<br />

Zeal/Accord/<br />

SPI<br />

Fisher &<br />

Paykel /<br />

Fanem/ Viasys


Annexure – 3<br />

Department <strong>of</strong> Ophthalmology<br />

1. Under VBCH<br />

S.N Technical Specifications <strong>of</strong> Equipment Mfg. Co.<br />

Preferred<br />

1 Nd-Yag Laser<br />

LASER<br />

Lumenis /<br />

Opto/Lynton<br />

Laser Source Q-Swiitched Nd:YAG<br />

Wavelength 1064 nm<br />

Energy 0,5 to 10 mj per pulse in 30 steps<br />

Spot Size


2 Fundus Camera<br />

Max Image Capture Rate: 3 images per second<br />

Capture Sensor: 5.3 Megapixel Sensor<br />

Video Capture: 640 x 480 @17fps<br />

Flash: 10 step LED<br />

Fixation: External fixation lamp<br />

Mount: Slip lamp mount/h<strong>and</strong> held<br />

Camera Module Dimensions: 4.8” (w) x 6.1” (d) x 9.7” (h)<br />

Camera Module Weight: approx 1 kg<br />

Retina Module Specification:<br />

Working Distance: 43mm<br />

Compensation range: -30 to 30 diopter<br />

Visual Observation: NIR or Visible light via laptop screen<br />

Mydriatic Field <strong>of</strong> view: 35 degrees<br />

Non-Mydriatic field <strong>of</strong> view: 30 degrees<br />

Biomedix/<br />

Leica/ Karl<br />

Kaps/ Karl<br />

Zeiss


2. Under DBCP<br />

S.N Technical Specifications <strong>of</strong> Equipment Mfg. Co.<br />

Preferred<br />

1 Ophthalmic Microscope<br />

Karl Zeiss /Karl<br />

Microscope An integrated 5-step apochromatic Kaps/ Moller<br />

magnification changer motorized focusing<br />

<strong>and</strong> fiber optic illumination.<br />

Wedel<br />

Magnification 5 step magnification changer with factors<br />

0.4/0.6/1.0/1.6 / 2.5<br />

Focusing Motorized<br />

Objectives F = 200mm /175mm<br />

Binocular Tube 45 o inclined tube f = 170mm with IPD: 55<br />

mm to 75 mm<br />

Illumination Fiber optic illumination with 12V 100W<br />

halogen reflector lamp<br />

Filters UV Filters, blue barrier filter<br />

Retinal Protection Device.<br />

Work flexibly Compact, design <strong>for</strong> flexible positioning.<br />

Motorized focus enables bi-manual work<br />

High capacity suspension system <strong>for</strong><br />

Precise<br />

movement<br />

Camera<br />

Attachments<br />

(Indian Make)<br />

that should be<br />

compatible with<br />

this microscope.<br />

increased functionality with accessories<br />

Smooth positioning through adjustable<br />

resistance<br />

Easy motion in the focusing plane with<br />

optional XY coupling<br />

Camera with video adaptor <strong>and</strong> beam<br />

splitter (Indian make)<br />

2 Cryo-Machine<br />

Totally non-electric Cryo Console Unit. The absence <strong>of</strong> electric<br />

connections ensures safe h<strong>and</strong>ling. Cryo is functionally designed<br />

to simplify Cataract, Retinal, <strong>and</strong> Glaucoma procedures by use <strong>of</strong><br />

a variety <strong>of</strong> surgical probes.<br />

Ophthalmic Deluxe Cryo<br />

The Cryo is foot operated <strong>and</strong> very sleek enabling easy h<strong>and</strong>ling<br />

<strong>and</strong> the pedal control enables instant freezing <strong>and</strong> defrosting.<br />

The console face includes a pressure indicator <strong>and</strong> ON-OFF<br />

reading <strong>for</strong> visual indication <strong>of</strong> the system.<br />

Special Features<br />

Basco<br />

/Kohden/Leica


Useful <strong>for</strong> Cataract, Retinal, Glaucoma <strong>and</strong> Intravitreous.<br />

Foot control provision <strong>for</strong> easy h<strong>and</strong>ling <strong>and</strong> instant freezing <strong>and</strong><br />

defrosting.<br />

Liquid nitrous or Carbon-DI-oxide gases technique is used <strong>for</strong><br />

low temperature achievement.<br />

Non-electric.<br />

1.It has got a reverse flow control mechanism <strong>and</strong> it cleans the<br />

inner line <strong>of</strong> the gas conveying tube automatically when the foot<br />

is released.<br />

2. It has got a seperate cylinder connector <strong>for</strong> fixing with the<br />

cylinder, which increases the length <strong>of</strong> the usages.<br />

3. Gas starts flowing in the probe only when the pedal is<br />

pressed. So the probe is saved with high pressure gas<br />

accumulated in the inner line, results long lasting <strong>of</strong> the probe<br />

<strong>and</strong> the gas is released in the console unit <strong>and</strong> minimising the<br />

noise.<br />

4. Breaken 'O' rings in the inlet <strong>and</strong> outlet <strong>of</strong> the probe will not<br />

stop the functioning <strong>of</strong> the cryo probe as the gas is passed<br />

through the probe only.<br />

5. For camp work the deluxe works properly <strong>and</strong> the 'O'<br />

rings(washer) will not get pluged, <strong>and</strong> it can be removed at any<br />

time when needed <strong>and</strong> any probe can be changed.<br />

6. Cylinder need not be brought near the patient since it has got<br />

a two meter cylinder connector to increase the length.<br />

7. Defrosting will take place without any trouble within two<br />

seconds, because <strong>of</strong> reverse flow control system.<br />

8. It had got ON-OFF indicator to check whether the gas enters<br />

inside the probe properly or not.<br />

3 Automated Perimeter<br />

Test Capability: Central & peripheral 100° (upto 160° with<br />

fixation shift)<br />

Test Mode: Static<br />

Stimulator Screen: Part Hemispherical radius 300mm.<br />

Integrating diffusing surface<br />

Background Illumination (with auto ambience level<br />

control): 10asb st<strong>and</strong>ard perimtery<br />

320 asb <strong>for</strong> blue on yellow (SWAP)<br />

Stimulus Source: Rear Projection LED<br />

Stimulus Color: Green or Blue<br />

Stimulus Size: Goldman III (0.43°) <strong>for</strong> st<strong>and</strong>ard perimetry<br />

Stimulus Intensity: 0.03 asb – 1000 asb<br />

Stimulus Duration: Adjustable 0.1 – 9.9 sec & adaptive<br />

Patient response Time: Adjustable 0.1-9.9 sec & adaptive<br />

Topcon/Zeiss/<br />

Medmont/<br />

Humphrey/<br />

Appasamy


Inter Stimulus delay: Adjustable 0.1-9.9 sec & adaptive<br />

Pupil measurement: semi automatic<br />

Specialty test Strategies: Flicker Sensitivity<br />

St<strong>and</strong>ard Test Strategies:<br />

• Threshold<br />

• Fast Threshold<br />

• Smart Threshold<br />

• Fast Scan<br />

• Screening<br />

• Neurological<br />

• 2-Zone<br />

• 3-Zone<br />

• Quantify Defect<br />

• Driving<br />

• Binocular Driving<br />

• Binocular Single Vision<br />

• Custom<br />

Fixation Methods: Digital eye tracking with camera view<br />

Heijl-Krakau blind spot method with camera view<br />

Fixation Target: Red LED 650nm<br />

Test lens Diameter: 38mm<br />

Patient Database Backup: CD,DVD,USB with auto procedure<br />

, on External PC<br />

User Interface: External PC, Monitor, keyboard & Mouse<br />

Electrical Requirements:<br />

110-230VAC 50/60Hz<br />

Power Consumption: max 35 W


Annexure – 4<br />

Department <strong>of</strong> Dermatology<br />

S.N Technical Specifications <strong>of</strong> Equipment Mfg. Co.<br />

Preferred<br />

Derma India<br />

/Lumenis<br />

/Lynton<br />

1 IPL Laser with RF<br />

IPL Laser with RF<br />

Treatment H<strong>and</strong>le: 3 Types<br />

Spot Size: 60mm x 15mm & 8mm x 40mm<br />

Spectrum:<br />

HR 610-1200nm<br />

SR 560-1200nm<br />

AC 430-1200nm<br />

PL 530-1200nm<br />

VL 585-1200nm<br />

RF Frequency: 750 ±10% KHz<br />

Energy Density: 20-50j/cm 2<br />

RF Duration: 0.1-3.0s<br />

Discharge Interval: 3-5s<br />

Input Power: 1200w<br />

1 st Pulse: 0.1-10.0 ms<br />

Power Supply: AC 220v 50Hz 10A<br />

Sub Pulse: 0.1-10.0 ms<br />

Cooling: WATer, Air, Semi-conductor cooling<br />

Cooling Temperature: -5°C<br />

Dimension: 650mm x 400mm x 450mm<br />

Net Weight: 25.5 Kgs<br />

2 Q-Switched laser<br />

Laser Type - Q – Switched Nd Yag laser<br />

Wave length - 1064 nm & 532 nm<br />

Frequency - upto 6 Hz<br />

Width <strong>of</strong> pulse - 20 ns<br />

Energy Density - ≤180 mJ (single pulse); ≤1000mj (direct<br />

pulse)<br />

Spot diameter - 1-6 nm<br />

Electrical requirement - 230 V/50Hz<br />

Cooling system - Internal water-to-air cooled<br />

Dimension (cm) - 24 X 40 X 18<br />

Net Weight - 7 kg<br />

Wattage - 420 W<br />

3 Ultrasonic Face Lift<br />

FEATURES<br />

Microprocessor based on operating system.<br />

S.M.P.S power supply<br />

Derma India /<br />

Lumenis/<br />

Lynton<br />

Derma India/<br />

Krupa<br />

Mediscan


Inbuilt Guard Protection.<br />

Feather Touch Keypad<br />

Three different type pules mode.<br />

Adjustable digital Intensity.<br />

Digital Count Down Timer.<br />

Auto Cut-<strong>of</strong>f Facility with beep sound.<br />

Two types <strong>of</strong> probe mode available.<br />

Shock pro<strong>of</strong> cabinet.<br />

Highly Powder Coated.<br />

SPECIFICATION:<br />

Power – 220v/240v 50 HZ AC.<br />

Frequency Out Put – 3Mhz.<br />

Power – 0 to 25w Adjustable.<br />

Intensity – 9 Levels<br />

APPLICATIONS<br />

FACE LIFT<br />

BREAST LIFT<br />

EYE CARE<br />

REMOVE WRINKLESS<br />

IMPROVE BODY LINES<br />

IMPROVES NECK & CHEEK LAXITY<br />

4 Diode Laser<br />

Technical Specifications<br />

Light Source - Diode (Continuous, Pulse Wave)<br />

Wavelength - 808 nm<br />

Optical Energy - Up to 50 J/cm 2<br />

Pulse Duration - 350 ms<br />

Repetition/Coverage Rate -1 – 10 Hz/hr (10 Hz), ST (1-10 Hz)<br />

Spot Size - 14 X 5.5 mm<br />

Optical guide - Sapphire Crystal<br />

Cooling - 0 º c<br />

Electrical Requirement - 230 V – 50 Hz<br />

Weight - 30kg<br />

5 Digital Ionotophoresis<br />

Power – A.C. 220/240v 50HZ.<br />

Microprocessor- Power Supply.<br />

Digital Procedure Count down Adjustable Time.<br />

Spike Guard Protection.<br />

Digital Force Display.<br />

Indivisual Gel <strong>for</strong> Application.<br />

Variable <strong>for</strong>ce adjustment.<br />

PROBE<br />

Pencil Probe with steel roller.<br />

Earthing Probe.<br />

Plastic Tray <strong>for</strong> lonotophoresis (2Psc)<br />

Derma<br />

India/Lumenis<br />

/Lynton<br />

Derma<br />

India/Krupa<br />

Mediscan


Electrode Plates.<br />

APPLICATIONS<br />

Pegmetation<br />

Under Eye Dark Circles.<br />

Oily Skin.<br />

Active Acne.<br />

Face Lifting.<br />

Skin Lighting.<br />

Hyperhidrosis.


Annexure – 5<br />

Department <strong>of</strong> Pathology & Microbiology<br />

S.N Technical Specifications <strong>of</strong> Equipment Mfg. Co. Preferred<br />

1 Automated Coagulation Analyzer<br />

• Machine should be r<strong>and</strong>om access, Bench Top fully<br />

automated walk away system.<br />

• Principal should be based on optic clot detection system.<br />

• It should have inbuilt windows based s<strong>of</strong>tware <strong>for</strong><br />

functioning <strong>of</strong> machine.<br />

• It should have touch screen <strong>and</strong> additional facility <strong>of</strong><br />

external keypad.<br />

• It should strictly work with inbuilt s<strong>of</strong>tware <strong>and</strong> no<br />

external computer should be required to avoid computer<br />

break downs.<br />

• Machine should be capable to per<strong>for</strong>m Clotting,<br />

chromogenic <strong>and</strong> immunologic test.<br />

• It should have 8 measuring channels working<br />

simultaneously <strong>for</strong> different test protocols.<br />

• Machine should have 5 channels <strong>for</strong> clot detection, 1<br />

channel <strong>for</strong> chromogenic <strong>and</strong> 1 channel <strong>for</strong> immunologic<br />

test.<br />

• Probe should have liquid level sensor, probe crash sensor,<br />

preheating <strong>for</strong> reagents.<br />

• Machine should have internal <strong>and</strong> external washing<br />

facility <strong>for</strong> probes after each step <strong>of</strong> reagent/ sample<br />

addition.<br />

• Syringe capacity should be 4 – 400 micro liters with<br />

precision <strong>of</strong> 1.0 micro liter.<br />

• Machine should have 23 reagent positions.<br />

• On board cooling facility should be available with the<br />

machine.<br />

• Machine should have reagent mixing facility. Machine<br />

should have stirrer <strong>for</strong> reagent mixing.<br />

• Machine should have 27 sample positions.<br />

• Facility to load primary tubes as well as sample cups<br />

simultaneously should be available.<br />

• Auto dilution facility should be available <strong>for</strong> samples.<br />

• Auto <strong>and</strong> manual calibration facility should be available<br />

Abott/Siemens/<br />

Tulip


with the machine.<br />

• It should have dedicated QC parameters like 7 controls,<br />

multirules etc.<br />

• Machine should work on bidirectional mode so that it can<br />

participate in LIS.<br />

• Machine should have inbuilt printer only <strong>and</strong> it should<br />

print calibration <strong>and</strong> reaction curve printouts.<br />

• Power supply should be AC 110V/220V, 60Hz/50Hz.<br />

• Machine should be CE/ US FDA approved.<br />

• Company should be ISO 13485 certified.<br />

2 Fully Automated three part cell counter (18 para)<br />

Fully automated Cell counter with 18 parameters <strong>and</strong><br />

with 3 differential counters & platelets with histograms<br />

Principles: WBC, RBC <strong>and</strong> PLT : electrical Resistance detection<br />

HGB: SLS Hemoglobin, dual transducer<br />

HCT: Cumulative Pulse Height Detection<br />

Parameters: 18 Parameters<br />

WBC, RBC, HGB, HCT, MCV, MCH, MCHC, PLT, LYM%, MXD%,<br />

NEUT%, LYM#, MXD#, NEUT#, RDW-SD, PDW MPV, P-LCR<br />

Automatic Sample probe cleaning function<br />

Automatic liquid circuit cleaning fast<br />

Working Mode: 24 hrs running continous, auto sleeping &<br />

wake up<br />

Throughput: Approx. 60 Samples / Hour<br />

Sample Volume: Whole Blood mode - 10µl, 20µl,<br />

Precision: Parameter Whole Blood Mode<br />

WBC 3.5%or lower<br />

RBC 2.0%or lower<br />

HGB 1.5%or lower<br />

HCT 2.0%or lower<br />

PLT 6.0%or lower<br />

Linearity:<br />

WBC 1.0-99.99x10 3 /µl (within ± 0.3x10 3 /µl or ± 3%)<br />

RBC 0.30-7.00x10 6 /µl (within ± 0.3x10 6 /µl or ± 3%)<br />

HGB 0.1-25.0g/dl (within ± 0.2 g/dl or ± 2%)<br />

HCT 10.00-60.0% HCT% (within ± 1.0 HCT% or ± 3%)<br />

PLT 10-999x10 3 /µl (within ± 10x10 3 /µl or ± 5%)<br />

(When RBC < 7.00x10 6 /µl)<br />

Data Storage: 240 patient results<br />

Touch screen back lighting LCD<br />

Interfaces: 1 parallel interface, 2 usb interface 2ps/2<br />

interface, 2 rs232 interface (with net)<br />

Built-in thermal Printer: 5x7 dots, 21 characters per line (128<br />

dots/line)<br />

Abott/Siemens/<br />

Tulip


Dimensions: Approx. 420x480x355<br />

W x H x D (mm)<br />

Weight (Kg): 28<br />

Power Consumption: 230 VA or less<br />

3 Binocular Microscope<br />

Fully imported Microscope with Siedentopf tube with 30’<br />

viewing angle in upper & lower position , tube can be<br />

rotated 360”<br />

Colour Corrected Infinity Optics with Plan Achromat 4x/0.12,<br />

10x/0.25, 40x/0.65, 100x/1.25 Oil Objectives<br />

Modular illumination with 30 watt Halogen light.<br />

Blue light intensity display on both sides <strong>of</strong> the st<strong>and</strong>.<br />

Fixed Koehler illumination with Abbe condenser 0.91/1.25<br />

Up gradable <strong>for</strong> Dark field, 40x Phase <strong>and</strong> contrast<br />

techniques.<br />

Quadruple 4x nosepiece pointing towards back.<br />

WF10x/18mm focusable eyepiece –1 NO. <strong>for</strong> binocular<br />

Microscope<br />

Precise & sensitive coaxial fine focusing control with special<br />

gear <strong>of</strong> 0.3 mm/rotation. Coarse drive 4mm/ rotation<br />

Magnification up to 1000x.<br />

St<strong>and</strong>ard set complete with built-in 6V20W halogen light<br />

illuminator, quadruple ball bearing nosepiece, focusing by Coaxil<br />

coarse <strong>and</strong> fine focusing controls, high resolution long<br />

barrel achromatic objectives 4x, 10x, 40x (Spring) <strong>and</strong> 100x<br />

(Spring, Oil Imm.), with an inclined binocular observation<br />

tube ratable through 360 degree fitted with fungus resistant,<br />

anti-reflaction coated prism, compensating widefield<br />

eyepiece WF10x (F.N. 18) <strong>and</strong> with right h<strong>and</strong> co-axil low<br />

drive mechanical stage, substage Abbe condenser 1.25 N.A.<br />

with iris diaphragm focusable with rack & pinion<br />

4 Rotary Shaker With 0 -15 minutes timer & speed<br />

regulator<br />

5 Four Door Vertical Refrigerator (Deep Freezer)<br />

Temperature range: -18 degree C to +6 degree C<br />

(adjustable with digital indicator cum thermostat)<br />

Insulation: 2” injected puff<br />

No <strong>of</strong> Doors: four insulated doors with gasket, lock & key<br />

with spring loaded hinges<br />

Construction: outer body/tank <strong>and</strong> doors are fabricated<br />

with S S Sheets <strong>of</strong> 20/22 swg.<br />

No <strong>of</strong> Shelves: three adjustable (wire mesh <strong>of</strong> S S 304<br />

quality)<br />

Condensing Unit: fitted on top with suitable kirloskar<br />

Nikon/Olympus/<br />

Zeiss<br />

Remi/St<strong>and</strong>ard<br />

Company<br />

Bluestar/Voltas/<br />

St<strong>and</strong>ard Company


Copel<strong>and</strong>/tecums compressor, condenser, fan motor,<br />

dryer.<br />

Electrical: operates on I phase, 230 volts, 50 Hz <strong>of</strong><br />

electric supply<br />

6 Fully Automated System <strong>for</strong> Identification & Antibiotic<br />

Susceptibility testing <strong>of</strong> micro-organisms<br />

• Requirement <strong>for</strong> the fully automated system <strong>for</strong><br />

Identification <strong>and</strong> Antibiotic Susceptibility testing <strong>of</strong> micro<br />

organisms <strong>for</strong> both Bacteria <strong>and</strong> Yeast.<br />

• System should be totally automated <strong>for</strong> sample<br />

st<strong>and</strong>ardization, panel inoculation <strong>and</strong> loading, incubation<br />

<strong>and</strong> reading with minimum number <strong>of</strong> manual steps.<br />

• System should be capable <strong>of</strong> processing atleast 30 cards<br />

at a time.<br />

• Along with Bacteria <strong>and</strong> Yeast system should be capable<br />

<strong>of</strong> identification <strong>of</strong> Anaerobes, corynebacterium <strong>and</strong><br />

fastidious organisms like Neisseria <strong>and</strong> Hemophilus <strong>and</strong><br />

HACEK group <strong>of</strong> organisms.<br />

• System should have separate panels <strong>for</strong> Identification <strong>and</strong><br />

antibiotic susceptibility testing thus making it more cost<br />

effective.<br />

• System should use reliable <strong>and</strong> world renown technology<br />

<strong>for</strong> identification like colorimetry<br />

• System should provide MIC values <strong>for</strong> drugs <strong>and</strong> the<br />

analysis <strong>of</strong> the Antibiotic susceptibility testing results<br />

should be done based on the CLSI guidelines.<br />

• System should be able to per<strong>for</strong>m the phenotypic analysis<br />

to give a complete detail on resistant phenotypes <strong>of</strong> the<br />

microorganisms based on the MIC values.<br />

• System should make use <strong>of</strong> panels with barcodes <strong>and</strong><br />

should have internal barcode scanning facility to facilitate<br />

the ease <strong>of</strong> data entry <strong>and</strong> data management<br />

• System should have the LIS facility thus enabling the bidirectional<br />

data transfer.<br />

• System should have the facility to transfer the data<br />

directly into excel sheet <strong>for</strong> further analysis.<br />

• System should allow the use <strong>of</strong> USB drivers or DVD <strong>for</strong><br />

data backup<br />

• System should make use <strong>of</strong> closed or sealed<br />

panels/strips/cards to ensure high level <strong>of</strong> security <strong>for</strong><br />

Siemens/<br />

Biomerieux/BD


oth test <strong>and</strong> users.<br />

• Panels used in the system should be sufficed with all the<br />

necessary reagents required <strong>for</strong> the analysis. Thus there<br />

should not be any need to use additional reagents other<br />

than those present in the panel.<br />

• System should be capable <strong>of</strong> providing rapid results i.e.<br />

within 2-10 hours <strong>for</strong> routine bacteria such as GNB <strong>and</strong><br />

GPC<br />

7 Automated Slide Stainer<br />

A Multi-disciplinary Slide bi-linear batch stainer <strong>of</strong>fering low<br />

cost access to automated staining.<br />

Easy to operate via h<strong>and</strong> held LCD controller<br />

10 program memory <strong>for</strong> rapid selection <strong>of</strong> desired protocol<br />

Should have full range <strong>of</strong> accessories including: Drying<br />

machine, fume hood, water baths <strong>and</strong> plumbing kit that can<br />

be added to a st<strong>and</strong>ard 10 bath unit.<br />

It should be portable<br />

Power Supply: 12V<br />

Applications:<br />

1. Cytology<br />

2. Haematology<br />

3. Microbiology<br />

4. Histopathology<br />

Capacity: 38 mL/ 10 bath<br />

St<strong>and</strong>ard Scope <strong>of</strong> Supply along with machine<br />

1. Drying module<br />

2. Fume hood<br />

3. External Bath with lid<br />

4. Add. Rack <strong>of</strong> 5 slide cap<br />

5. Add.Dish/Bath<br />

6. Tap<br />

7. Plumbing kit<br />

Biomerieux/<br />

Siemens<br />

8 Balance Weight Machine Metlar<br />

Tolado/Biomerieux


Annexure – 6<br />

Department <strong>of</strong> Orthopedic<br />

S.N Technical Specifications <strong>of</strong> Equipment Mfg. Co. Preferred<br />

1 Battery Operated Drill Machine<br />

Drill/Reamer H<strong>and</strong>piece. 1<br />

Battery operated, Drill speed 750 RPM. Tourque 50<br />

In. lbs. Reaming speed 250 RPM. Tourque 150 In. lbs.<br />

With 4.9mm Cannulation , With Facility For Pulse<br />

Lavage Attachment, should be Single Trigger operated<br />

with reverser <strong>and</strong> <strong>for</strong>ward facility by the single trigger<br />

Oscillating Saw H<strong>and</strong>piece 1<br />

Battery Operated, Saw Speed 15,000CPM Arc 4º. with<br />

8 Position rotating head. Saw Blade should be fittend<br />

in with pull up <strong>and</strong> down position ( vertical)<br />

Saw Blades 10<br />

Universal Battery Charger 1<br />

UL2601-1 Complete battery charger with four charging<br />

bays<br />

Battery 8<br />

14.4 Volt Nickel Metal Hybride (NiMH) rechargeable,<br />

Autoclavable Battery,<br />

Connections For the above H<strong>and</strong>piece<br />

All the connecting accessories should be attach by<br />

Pulling Mechanism <strong>for</strong> easy coupling<br />

(1) Jacobs Coupler <strong>for</strong> Drilling, with 750 RPM Speed 2<br />

(2) A.O.Synthes Coupler, with 750 RPM Speed 2<br />

(3) Synthes Reamer Coupler, with 250 RPM Speed 2<br />

(4) Wire <strong>and</strong> Pin Driver Coupler, with 750 RPM Speed,<br />

should accept wires <strong>and</strong> pins from 1.6mm to 2.8mm<br />

2<br />

Microaire/Stryker/<br />

Synthes<br />

(5) SS Case 2<br />

2 Hohman Variable Retractors Kalellkar/<br />

Synthes/Teknomedi<br />

cal/Shushrut/ Inor<br />

3 Bone Punches Kalellkar/<br />

Synthes/Teknomedi<br />

cal/Shushrut/ Inor<br />

4 Peripheral Nerve Locator<br />

Kalellkar/<br />

1. Constant current<br />

Synthes/Teknomedi<br />

2. Microprocessor based.<br />

3. LED display.<br />

4. Current range – 0 to 99 mA, variable in steps at 5mA.<br />

5. Pulse width – 200 microseconds.<br />

6. Availability <strong>of</strong> single twitch, train <strong>of</strong> four, tetanus (50Hz),<br />

cal/Shushrut/ Inor


double burs stimulation 3:3, post titanic count modes <strong>of</strong><br />

stimulation<br />

7. Single twitch every 1 seconds option.<br />

8. Single twitch every 10 seconds option.<br />

9. Train <strong>of</strong> four every 10 seconds option.<br />

10. 9 volt battery operated.<br />

5 Broken Screw removal set (Hollow will)<br />

Graphic case <strong>for</strong> instruments (empty) 1<br />

Assembly pin 1<br />

Assembly <strong>for</strong>ceps 1<br />

Connecting end to hollow reamer 02.00002.015 1<br />

Connecting end to hollow reamer 02.00002.020 1<br />

Connecting end to hollow reamer 02.00002.027 1<br />

Connecting end to hollow reamer 02.00002.035 1<br />

Connecting end to hollow reamer 02.00002.045 1<br />

Connecting end to hollow reamer 02.00002.065 1<br />

Connection end with cent. Pin <strong>for</strong> 02.00002.015 1<br />

Connection end with cent. Pin <strong>for</strong> 02.00002.020 1<br />

Connection end with cent. Pin <strong>for</strong> 02.00002.027 1<br />

Connection end with cent. Pin <strong>for</strong> 02.00002.035 1<br />

Connection end with cent. Pin <strong>for</strong> 02.00002.045 1<br />

Connection end with cent. Pin <strong>for</strong> 02.00002.065 1<br />

Hollow reamer <strong>for</strong> screws 1.5mm 1<br />

Hollow reamer <strong>for</strong> screws 2.0mm 1<br />

Hollow reamer <strong>for</strong> screws 2.7mm 1<br />

Hollow reamer <strong>for</strong> screws 3.5+4.0mm 1<br />

Hollow reamer <strong>for</strong> screws 4.5mm 1<br />

Hollow reamer <strong>for</strong> screws 6.5+7mm 1<br />

Extraction bolt <strong>for</strong> screws 1.5 mm 1<br />

Extraction bolt <strong>for</strong> screws 2.0 mm 1<br />

Extraction bolt <strong>for</strong> screws 2.5 mm 1<br />

Extraction bolt <strong>for</strong> screws 3.5 + 4 mm 1<br />

Extraction bolt <strong>for</strong> screws 4.5 mm 1<br />

Extraction bolt <strong>for</strong> screws 6.5 + 7 mm 1<br />

Conical extraction screw <strong>for</strong> screws 1.5+2.0 mm 1<br />

Conical extraction screw <strong>for</strong> screws 2.7 + 3.5 + 4.0 mm 1<br />

Conical extraction screw <strong>for</strong> screws 4.5 + 6.5 + 7.0 mm 1<br />

Holding <strong>for</strong>ceps 1<br />

Straight hollow gouge, straight left 1<br />

Mallet 200g 1<br />

Universal chuck cannulated with T-h<strong>and</strong>le 1<br />

T-h<strong>and</strong>le with quick coupling 1<br />

Sharp hook, L. 150 mm 1<br />

Synthes /Zimmer


6 Minimally invasive& mini-open Discectomy <strong>and</strong><br />

fusion system <strong>for</strong> both cervical <strong>and</strong><br />

thoracolumbar use.<br />

Minimally Invasive discectomy& fusion system <strong>of</strong><br />

Herniated Nucleoluspulpous <strong>and</strong> bony decompression <strong>of</strong><br />

the root.<br />

System should to allow PLIF, TLIF,Laminectomy,<strong>and</strong><br />

Facectotomy, Ligament Flavum removal, Nerve root<br />

retraction <strong>and</strong> discectomy.<br />

System should have capability to multi-Level posterior<br />

fusion allowing pedicle to pedicle access at least40mm<br />

<strong>for</strong> fusion.<br />

System should be adaptable to camera, Microscope<br />

<strong>and</strong> Loop.<br />

The following components should be integral part <strong>of</strong><br />

system.<br />

1. Introducing instruments :-<br />

System should have sequential dilators <strong>and</strong> outer<br />

sheath <strong>for</strong> endoscope to avoid cutting <strong>of</strong> muscles <strong>and</strong><br />

hence providing Muscle Sparing Approach to Spinal<br />

Surgery.<br />

2. Flexible Arm Assembly :<br />

Flexible arm with rod connection to secure the<br />

introducing system to OT table should be adjustable in<br />

multi direction.<br />

Should have black bayoneted instruments <strong>for</strong> universal<br />

applications with Endoscope/microscope/ loop.<br />

The following items should be manufactured by firms<br />

<strong>of</strong> international repute <strong>and</strong> should have US FDA<br />

approval.<br />

Micro Endoscopic Discectomy <strong>and</strong> fusion<br />

System<br />

Guide wire<br />

Flexible Arm Assembly 1<br />

Dilator Diameter<br />

1 each<br />

5.3mm,9.4mm,12.8mm,14.6mm,16.8mm,<br />

18.8mm <strong>and</strong> 20.8mm, 22.8mm, 24.8mm<br />

Bed Rail attachment 1<br />

1<br />

Meditronic/Teknom<br />

edical/SMPL/Inor


7<br />

Exp<strong>and</strong>able retractor 25 x 60, 70mm 2 each<br />

Openers <strong>for</strong> above 1 each<br />

RF Electrode <strong>for</strong> Mitek VAPR System<br />

90° Electrode with Suction Hole – Model S90 – 2 nos.<br />

50° Electrode with Suction Hole – Model S50 – 2nos.<br />

90° Hook Electrode -1 no.<br />

Depuy Mitek<br />

8 Flexible Reamer<br />

Fixed Head Reamer Shaft with Synthes type reaming coupler-<br />

Dia. 6 mm to 15 mm with difference <strong>of</strong> 0.5 mm<br />

Manman<br />

9 Wire Cutter tungsten tip with 3 mm wire cutter length 9”, Synthes/Zimmer/<br />

double action with straight jaw<br />

Inor<br />

10 Specectrum Shoulder Arthoscopy<br />

Codman/Depuy<br />

CordCutter *EA 1 Mitek/Kallelkar<br />

Arthro Knot Manip Full *EA 1<br />

Arthro Calibrated Probe*EA 1<br />

Arthro Rasp 20 UpBend *EA 1<br />

Arthro TissLib Blade Up*EA 1<br />

Expressew III Flexible Suture Passer 12<br />

Expressew III Flexible Suture Passer Needles 15<br />

Clever Hook, right 1<br />

Clever Hook, left 1<br />

Sixter, right 1<br />

Sixter, left 1<br />

Suture Manipulator 1<br />

Switching Stick, 4mm 1<br />

SS Box <strong>for</strong> Above 1<br />

11 Reusable Monopolar Cautery Cords Galtron/St<strong>and</strong>ard<br />

Company<br />

12 Pencil Drill <strong>for</strong> H<strong>and</strong> Surgery<br />

Manman/<br />

Pen Type Drill H<strong>and</strong>piece<br />

Is should designed <strong>for</strong> general purpose.<br />

Medtronic/ Codman<br />

It should be useful <strong>for</strong> superficial use in Foot, H<strong>and</strong> <strong>and</strong> Paediatric Surgery<br />

Simple holding mechanism<br />

Bottle shape<br />

Com<strong>for</strong>table grip<br />

Light weight – 300 gms.<br />

Powerful micro motor inside.<br />

Autoclavable with special connector<br />

Should Hold 1,1.5,2mm Drill Bit / Bur<br />

Mini Sagittal Saw H<strong>and</strong>piece<br />

Bottle shape<br />

Com<strong>for</strong>table grip


Light weight – 300 gms.<br />

Powerful micro motor inside.<br />

Autoclavable with special connector<br />

Saw Blade<br />

5 Different Shapes from 0.3mm to 0.5mm thickness 10<br />

Power Consol 1<br />

Knob <strong>for</strong> Linear Speed Control Starting from 0-25000 cpm<br />

Toggle switch <strong>for</strong> selecting Saw & Drill.<br />

Slide Switch <strong>for</strong> cw / ccw<br />

Indicator <strong>for</strong> status <strong>of</strong> Foot Control<br />

Mains on / <strong>of</strong>f switch<br />

Sockets <strong>for</strong> drill, Foot Control & saw<br />

Socket <strong>for</strong> AC power supply 220 V / 5 A<br />

Accessories<br />

Supply Cord 1<br />

Autoclavable<br />

Smooth touch<br />

Length 3 mtr.<br />

Push pull connectors<br />

Feather weight<br />

Foor Control 1<br />

On / Off switch<br />

2.5mtr. long cord<br />

Not to be autoclaved<br />

Power supply cord 1<br />

Bur <strong>of</strong> Different Sizes 10<br />

Drill bits <strong>of</strong> Different size from 1, 1.5, 2, 25mm 10<br />

13 Centrifuge – 1800 rpm Remi /St<strong>and</strong>ard<br />

Company<br />

14 Reusable bipolar cautery cords Galtron/ St<strong>and</strong>ard<br />

15 High definition Camera System with Xenon Light Source, 3<br />

chip camera, light cable (thicker <strong>and</strong> longer), video imaging<br />

capturing device<br />

• HD 3CCD CAMERA<br />

1. It should have Max. Resolution 1920 x 1080 Pixel, in<br />

DVI <strong>for</strong>mat.<br />

2. Progressive Scan CCD should be - 1/3" x 3<br />

3. Aspect Ratio should be 16:9<br />

4. Sensitivity should not be more than 1.5 Lux. to get<br />

optimum color resolution with all kind <strong>of</strong> light source.<br />

5. It should have 3 Programmable buttons on head.<br />

6. It should have Freeze Function through button on<br />

Company<br />

Karl Storz/ Richard<br />

Wolf/Maxer/Stryker


head .<br />

7. There should be a facility <strong>of</strong> Digital Zoom <strong>and</strong> Optical<br />

zoom also.<br />

8. It should have Facility to invert or flip the image <strong>for</strong><br />

allowing surgeon to operate from opposite side <strong>of</strong><br />

camera.<br />

9. There should be a function <strong>of</strong> multi step digital<br />

enhancer.<br />

10. Facility to select different light sources such as LED,<br />

Xenon, Halogen <strong>for</strong> optimum colors on all.<br />

11. It should have detachable C-mount <strong>for</strong> use <strong>of</strong> different<br />

couplers .<br />

12. Video Outputs - HD-SDI -2, Y/C - 2, Composite -2, DVI<br />

-1 , RGB -1<br />

13. Key Board Connectivity <strong>for</strong> data input.<br />

14. Specialist wise Surgery Selection <strong>for</strong> optimum setting<br />

<strong>for</strong> different surgeries.<br />

15. It should also have function <strong>of</strong> Window, Gain & Antimoire<br />

filter.<br />

16. It should be certified with EN60601-1 , EN60601-2-<br />

18 & CE according to MDD93/42/EEC.<br />

� FULL HD LCD MEDICAL GRADE MONITOR<br />

1. Size <strong>of</strong> the monitor should not less than 21”.<br />

2. Monitor should have full HD, 1920 x 1200 resolution.<br />

3. It should accepts High Definition signal <strong>of</strong> 1920x1200<br />

through DVI-D & HD-SDI<br />

4. It should have digital DVI-D input.<br />

5. It should also have other inputs like HD-SDI, RGBS,<br />

composite, s-video etc.<br />

6. All other on screen menu adjustments like gamma,<br />

color, contrast, brightness etc should be provided.<br />

7. Viewing angle should be 180°.<br />

8. It should be provided with Table st<strong>and</strong>.<br />

9. It should be certified with CE .<br />

• LIGHT SOURCE XENON - 300W<br />

1. It should have integrated 300W xenon bulb .<br />

2. It should have manual or electronic iris to adjust light<br />

intensity.<br />

3. Preferable the lamp hour meter should be on the<br />

front panel <strong>of</strong> light source.<br />

4. It should have universal Turret to except various make


fiber optic cables.<br />

5. There should be easy replacement <strong>of</strong> xenon lamp.<br />

6. It should provide with compatible Fiber Optic Light<br />

cable .<br />

7. It should be certified with ISO 13485 & CE - 93/42/EEC<br />

HD VIDEO RECORDING SYSTEM.<br />

1) The system should be a medical grade panel PC with<br />

High Definition video capture card.<br />

2) The system should be configured with Micros<strong>of</strong>t<br />

Windows 7 operating system , 500 GB hard disk , Intel<br />

Core 2 Duo processor, DVD R/W optical drive, 22”TFT<br />

touch screen display.<br />

3) The system should capable to capture <strong>and</strong> compress<br />

video signals up to a resolutions <strong>of</strong> 1080p in real time.<br />

4) The system should be suitable <strong>for</strong> digital video signals<br />

SDI , HDMI , DVI <strong>and</strong> analog video signals<br />

COMPONENT , S-VIDEO & COMPOSITE.<br />

5) There should be integrated s<strong>of</strong>tware <strong>for</strong> electronic<br />

management <strong>of</strong> medical records.<br />

6) System should able to stream video & audio signals<br />

from the OT to any computer on the local network.<br />

Endoscopy Trolley :-<br />

There should be 5 shelves , & locker at bottom , sturdy ,at<br />

least one plug should be 15amp,& monitor fixing facility on<br />

top.<br />

Voltage stabilizer – Servo 2KVA , Tolarance ± 1% , ------ 1No.


Annexure – 7<br />

Department <strong>of</strong> Physiotherapy<br />

S.N Technical Specifications <strong>of</strong> Equipment Mfg. Co. Preferred<br />

1 Comprehensive Rehabilitation System<br />

Biotech/BTE<br />

The Rehabilitation Equipment should be a computer-controlled Technologies/<br />

Machine that can simulate functional tasks <strong>for</strong> the purpose Contrex<br />

<strong>of</strong><br />

assessment <strong>and</strong> training, <strong>and</strong> allow <strong>for</strong> isolated muscle <strong>and</strong> joint<br />

testing <strong>and</strong> training <strong>for</strong> upper <strong>and</strong> lower extremities.<br />

Equipment should be supplied with minimum following<br />

attachments to cover, Rehabilitation , Work simulation <strong>and</strong><br />

Sports testing <strong>and</strong> training :<br />

� Key<br />

� Ball knob: with more than 1.5 inch diameters<br />

� Flat knobs: with minimum two sizes<br />

� Screwdrivers: large <strong>and</strong> medium sized<br />

� Large <strong>and</strong> small adjustable lever with interchangeable<br />

h<strong>and</strong>le<br />

� Fixed axis linear motion attachment<br />

� Grip tool<br />

� Pinch tool<br />

� Steering wheel<br />

� Multiple h<strong>and</strong>le crossbar/Ladder climb attachment<br />

� Cable system to allow linear motion (such as<br />

lifting)<strong>and</strong> 3 dimensional movement (such as PNF<br />

patterns <strong>and</strong> work task simulations)<br />

� Tool adapter to use st<strong>and</strong>ard wrenches & screwdrivers<br />

as exercise tools.<br />

� Calibration Kit<br />

� Swing Tool which can Simulate swings <strong>for</strong> various<br />

sports activities including Trunk Rotation , Lumbar<br />

Stabilization, Elbow Extension, Forearm<br />

Pronation/Supination<br />

� Cricket Attachment which can Simulate Cricket ball<br />

throw, PNF Diagonal Patterns, Triceps Extension,<br />

Scapular Retraction/ Adduction<br />

� Padded Wrist Straps<br />

� Waist Belt Strap<br />

� Thigh Cinch Strap<br />

� Padded Harness<br />

� Ankle Cinch Strap<br />

Equipment should have following minimum Exercise<br />

types & modes


• Isometric<br />

• Isokinetic: concentric/eccentric,<br />

concentric/concentric concentric/<strong>of</strong>f<br />

• Isotonic: concentric/eccentric,<br />

concentric/concentric concentric/<strong>of</strong>f<br />

• CPM<br />

Actuator / Dynamometer height should have adjustable<br />

height range from approx 20 to 82 inches above floor.<br />

Equipment should have facility to be also used by<br />

wheelchair patients<br />

Actuator / Dynamometer rotation position should be<br />

adjustable full 360-degree rotation<br />

Equipment should be supplied with detachable Patient chair<br />

/ Bench<br />

Equipment should be supplied with suitable cart ( Trolley) ,<br />

Computer <strong>and</strong> s<strong>of</strong>tware with following minimum features :<br />

� Monitor with Touch screen interface s<strong>of</strong>tware<br />

� Lift testing protocol<br />

� St<strong>and</strong>ardized strength protocol<br />

� Isokinetic <strong>for</strong>ce curves<br />

� Motor control training feedback in CPM<br />

� Anatomy S<strong>of</strong>tware<br />

Immediate comparisons <strong>of</strong> results at the end <strong>of</strong> each<br />

exercise<br />

2 Cryotherapy Unit<br />

• Unit should provide cold air up to -32° C.<br />

• Unit should use normal air as princple energy source,<br />

no consumable required to run machine<br />

• It should have air capacity up to 1500 l/min<br />

• System should supply with one tube, one slotted<br />

nozzle <strong>and</strong> 5mm,10mm <strong>and</strong> 15 mm size nozzle<br />

attachments.<br />

• Safety class 1 Type B<br />

• Unit should have castores <strong>for</strong> easy mobility.<br />

• Should work on 230VAC.<br />

3 Multi CPM Unit<br />

All CPM should work separately <strong>and</strong> simultaneously.<br />

Knee CPM<br />

• Unit should be able to work on adult <strong>and</strong> pediatric<br />

• Unit should have facility automatically increasing the<br />

programmed flexion angle by 1° every hour up to 5 ° per<br />

24 hour period <strong>of</strong> time<br />

• Unit should have facility to work more in working ROM<br />

Biotech/Zimmer/<br />

Physiomed<br />

DJO Global /<br />

Ormed


mimicking oscillation with h<strong>and</strong>.<br />

• Unit should Accelerates quicker through the non-working<br />

ROM<br />

• Unit should have facility when the patient’s threshold <strong>for</strong><br />

pain is reached, allows the unit to continue working the<br />

affected limb but at a reduced flexion angle limit.<br />

• Force Reversal: Safety allowing the therapist to set an<br />

amount <strong>of</strong> passive <strong>for</strong>ce without causing damage to the<br />

surgery or unnecessary pain.<br />

Should have following Specification:<br />

• extension (-10°) to (120°)<br />

• Speed Range : 35 degree min to 150 degree min<br />

• Overall Length 37".<br />

• High-quality, easy to attach patient kit<br />

• Carriage width : 28cm (11 in.)<br />

• Power : -230VAC-50/60Hz,<br />

Safety Class : Class I, Type B<br />

Safety Tests : CE0413, UL 2601-1 CAN/CSA 601.1<br />

IEC/EN 601.1, IEC/EN 60601-1-1<br />

Shoulder CPM<br />

• The Shoulder CPM should have following features:<br />

• H<strong>and</strong>-held pendant<br />

• Storage card <strong>for</strong> storing programmed values.<br />

• universal left/right design <strong>for</strong> both arm activity.<br />

• Anatomically correct adjustment<br />

• Motor Control: on/<strong>of</strong>f<br />

• Reverse-on-load – unit should switch to the opposite<br />

direction when patient resistance increase the target set<br />

value.<br />

• Patient compliance meter should calculates the<br />

cumulative patient use time<br />

• Warm-up mode – the unit should recognizes the start <strong>and</strong><br />

stop angles <strong>and</strong> midpoint. From that point, motion should<br />

initiated 3 degrees from all angles until full ROM is<br />

achieved.<br />

• Pauses: 0-20 seconds<br />

• Speed: 0-100%<br />

• Timer: 0-250 minutes<br />

The Shoulder CPM should allows the following motions <strong>of</strong> the<br />

shoulder joint:<br />

Adduction/Abduction 0°- 30° - 175°<br />

Internal/External Rotation 90°- 0° - 90°<br />

Elevation (Flexion) with 60° - 90° flexion <strong>of</strong> the elbow 30° -<br />

175°<br />

Ante/Retroversion (horizontal adduction/abduction) set


manually 0° - 125°<br />

Mains Power: 230V, 50/60 Hz,<br />

Elbow CPM<br />

• It should have facility <strong>of</strong> Timer in minutes or hours or<br />

continuous operation<br />

• It should have 0 – 59 seconds pause time<br />

• It should have Speed range 1 % to 100 %<br />

• Reverse on load in steps (motor A <strong>and</strong> B separately)1 – 25<br />

/ patient safety feature<br />

• It should have facility <strong>of</strong> plantar flexion/extension or<br />

pronation/supination<br />

• It should have Plantar extension/flexion -5° / 0° / 140°<br />

• It should have pronation/supination 90° / 0° / 90°<br />

• It should have facility <strong>for</strong> gradual <strong>and</strong> smooth increase <strong>of</strong><br />

the range <strong>of</strong> motion<br />

• It should have higher rate <strong>of</strong> motion in EROM<br />

• It should display graphic presentation <strong>of</strong> the overall<br />

treatment cycle<br />

• It should have warm-up protocol <strong>for</strong> gradual progression<br />

to the maximum range <strong>of</strong> motion<br />

• It should separate exercising in both directions<br />

• It should have Patient chip card storage facility <strong>for</strong> store<br />

patient-specific therapy parameters<br />

• It should have less than 30kgs Weight<br />

• It should supply with dedicated fix chair <strong>for</strong> CPM<br />

4 Microwave Diathermy<br />

• It should have Easy touch button control.<br />

• It should have Adjustable arm<br />

• It should have Overheating (80ºC) is prevented with<br />

magnetron protective circuit.<br />

• System Operation start only at zero intensity.<br />

• System should supply with circular irradiator.<br />

• It should have facility to give treatment to any part <strong>of</strong><br />

body by set direction <strong>and</strong> angle <strong>of</strong> arm<br />

Technical Specification:<br />

• Power : AC 220V, 50Hz<br />

• Output Power : 0 – 240W<br />

• Output Frequency : 2450Mhz<br />

• Wavelength : 124.4 nm<br />

• Output modes : (1) Continuous (2) Intermittent<br />

• Timer : 5 to 30 Minute<br />

5 Exercise Bike<br />

System should have facility <strong>of</strong> integrated chip card system so<br />

that all parameter should set according patient condition.<br />

Biotech/<br />

Physiomed<br />

Proxomed/Scifit


• Clear access <strong>for</strong> easy positioning <strong>for</strong> training<br />

• It should have Horizontal seat adjustment according patient<br />

height.<br />

• It should have Transport rollers <strong>for</strong> moving facility.<br />

• Maximum patient weight capacity should be 190kg.<br />

• Accuracy 5% to 400 W, from 400 W 10%<br />

• It should have Induction brake system<br />

• It should have Speed range from 25-115 rpm<br />

• It should have Power range 20-500 W<br />

• Power should Increment in 5 W steps<br />

• It should have following Training Programs<br />

1. Quick start,<br />

2. pulse-based programs,<br />

3. constant watt programs,<br />

4. Isokinetic,<br />

5. hill training<br />

• It should have facility <strong>of</strong> POLAR pulse measurement single<br />

channel ECG accuracy<br />

• It should have facility <strong>of</strong> Adjustable pedals<br />

6 Trapeze<br />

Mounts easily to most metal frame headboards (use the<br />

Trapeze Base, below, <strong>for</strong> nonmetal headboards) <strong>and</strong> is<br />

constructed from chromeplated, heavy gauge two-piece<br />

square steel tubing <strong>for</strong> maximum support. Easy to install<br />

without tools (mounting brackets included).Easy to adjust <strong>for</strong><br />

height, length, <strong>and</strong> horizontal position. Can hold up to 250<br />

lbs.<br />

7 4 Channel TENS<br />

Features :-<br />

� should have Micro controller based plat<strong>for</strong>m <strong>for</strong> optimum<br />

accuracy<br />

� Should have Back Light LCD Display <strong>for</strong> clear viewing.<br />

� Should have Various Modes like Continuous, Burst, Pulse<br />

Width & Frequency Modulation.<br />

� Should have 4 channel to cover more patient at a time<br />

with different Intensity control.<br />

� ABS Shock Pro<strong>of</strong> cabinet.<br />

� Portable & Light Weight.<br />

Specification:-<br />

Biotech/Alay/ Dev<br />

rehab<br />

Biotech/Alay<br />

Medins/ Dev<br />

Rehab/ Bionics


OUTPUT CHANNELS : 4<br />

MODE : a) Continuous : Variable Frequency from 4 to<br />

150 Hz<br />

b) Burst – Variable from 0.5 to 4 Sec<br />

c) FM – It automatically generates impulses from 4<br />

to 150 Hz<br />

d) PWM – It automatically generates impulses <strong>of</strong><br />

variable pulse width from 30 to 250 micro second<br />

INTENSITY: Adjustable from Zero to 120 volts <strong>for</strong> each<br />

channel.<br />

DISPLAY : Back Light LCD Display.<br />

WAVE SHAPE : Biphasic<br />

MAINS SUPPLY : 230 V A.C.<br />

8 Bolsters<br />

• It should make from good quality <strong>for</strong>ms without any<br />

sharp corner.<br />

• It should have three different size<br />

1. Small<br />

2. Medium<br />

3. Large<br />

9 Wobble Board<br />

• It should have aggressive anti-slip base design with a<br />

sensory stimulation surface to <strong>of</strong>fer a new per<strong>for</strong>mance<br />

level to balance training.<br />

• It should have rounded bottom that moves in all<br />

directions.<br />

• It should made from lightweight molded plastic.<br />

10 High Frequency Chest Wall Oscillations – Adult &<br />

Pediatric<br />

A system to remove excess mucus from lungs.<br />

Should have full coverage pulsation<br />

Should have a garment system <strong>and</strong> pump system to generate<br />

high frequency pulsation<br />

Unit should be programmable to suit individual patient needs<br />

System should be supplied with three different size garments<br />

to cover patients from pediatric to adults.<br />

11 Positive Expiratory Pressure Measurement System- Adult<br />

& Pediatric<br />

• System should measure combined, mouth <strong>and</strong> nasal<br />

pressure measurements<br />

• System should have digital display <strong>of</strong> the results<br />

• It should small, portable <strong>and</strong> lightweight<br />

Biotech/Alay<br />

Medins/ Dev<br />

Rehab<br />

Therab<strong>and</strong>/ Alay<br />

Medins/ Dev rehab<br />

Biotech/<br />

Electromed/<br />

Respironics/<br />

Philips<br />

Biotech/Micro


• System should used latest piezo resistive pressure<br />

sensing technology<br />

• System should battery operated<br />

Technical Specifications<br />

• System should Measure Maximum Expiratory<br />

Pressure (MEP),Maximum Inspiratory Pressure (MIP)<br />

<strong>and</strong> Sniff Nasal Inspiratory Pressure (SNIP)<br />

• System should have operating pressure +/-300 cmH20<br />

(+/-5PSID)<br />

• System should have burst pressure +/-700 cmH2O (+/-<br />

20PSID)<br />

• System should have resolution 1 cmH2O<br />

• System should have Accuracy +/-3%<br />

• Power Supply Single 9 volt battery<br />

12 Heavy Duty percussion System<br />

• System should provide percussion, oscillation <strong>and</strong><br />

vibration.<br />

• It should use <strong>for</strong> physical therapy, respiratory therapy<br />

<strong>and</strong> sports medicine application.<br />

• It should provide directional stroking action combines<br />

both Horizontal <strong>and</strong> Vertical Forces is must.<br />

• Variable frequency controls 10 to 60 cycles per second<br />

• It should have facility <strong>of</strong> dial controls with visual<br />

display <strong>of</strong> CPS, time <strong>and</strong> pulsation range.<br />

• It should have high quality 1/17 horse power motor<br />

• Should have the international safety st<strong>and</strong>ard like CE.<br />

• It should supply with following different applicators<br />

1. Percussion adaptor<br />

2. Small sponge adaptor<br />

3. Large sponge adaptor<br />

4. Round firm adaptor<br />

5. Curved sponge adaptor<br />

• It should supply with rolling caster st<strong>and</strong> <strong>and</strong><br />

accessory tray.<br />

• It should operated on 230Volts/50 Hz<br />

• St<strong>and</strong>ard Scope <strong>of</strong> supply is included.<br />

Biotech/G5


Annexure – 8<br />

Department <strong>of</strong> ENT<br />

S.N Technical Specifications <strong>of</strong> Equipment Mfg. Co. Preferred<br />

1 Operating Microscope <strong>for</strong> ENT, Plastic, Neuro <strong>and</strong><br />

Spine<br />

Apochromatic Optics:<br />

Motorized focus, working distance 200-500mm<br />

Motorized zoom; 1:6 zoom ratio<br />

10x magnetic widefield eyepiece with integrated<br />

eyecups<br />

12.5x magnetic widefield with integrated eyecups<br />

Illumination:<br />

180W Xenon light source<br />

Automatic Iris Control <strong>for</strong> adjusting the illumination to<br />

the field <strong>of</strong> view<br />

Display <strong>of</strong> remaining lamp life time<br />

System Setup:<br />

Manual Balance with guidance via user interface<br />

General Video: Integrated 17” digital display<br />

Connectivity/data Management:<br />

Video-in <strong>for</strong> external SD video sources<br />

Can be integrated with external 3 chip CCD camera<br />

System Operation:<br />

Multifunctional programmable h<strong>and</strong>grips<br />

Magnetic clutches <strong>for</strong> all system axes<br />

Central user interface<br />

Overhead display <strong>for</strong> showing important system<br />

parameters<br />

St<strong>and</strong>ard Scope <strong>of</strong> Supply will include:<br />

1. Microscope with support arm<br />

2. Electrical components<br />

3. Xenon Illumination<br />

4. Dust Cover<br />

5. Light guide 2.5m with 90° connector<br />

6. Floor st<strong>and</strong> with fixed column<br />

7. Tiltable binocular tube f=170mm, 180 degrees<br />

8. Widefield pushin eyepiece 10x<br />

9. Pack <strong>of</strong> 5 sterile drapes, type 71<br />

10. Pack <strong>of</strong> 20 sterile drapes, type 88<br />

11. Coupling <strong>for</strong> microscope<br />

Karl Zeiss/Karl<br />

Kaps/Olympus


12. Pack <strong>of</strong> 6 asespsis caps <strong>for</strong> PD adjustment <strong>of</strong><br />

180° tube<br />

13. Pack <strong>of</strong> 6 asespsis caps 27mm<br />

14. Pack <strong>of</strong> 6 asespsis caps 12 mm<br />

15. Pack <strong>of</strong> 6 asespsis caps 22 mm<br />

2 Nasal endoscope Adult 0 degree 4 mm<br />

• Should have Wide angled field <strong>of</strong> vision.<br />

• Should have 3 types <strong>of</strong> adaptors <strong>for</strong> fiber optic<br />

cable.<br />

• Should have working length <strong>of</strong> 175 mm<br />

• Should be Autoclavable.<br />

3 Nasal Endoscope Pediatric 0 degree 2.7 mm<br />

• Should have Wide angled field <strong>of</strong> vision.<br />

• Should have 3 types <strong>of</strong> adaptors <strong>for</strong> fiber optic<br />

cable.<br />

• Should have working length <strong>of</strong> 50 mm<br />

• Should be Autoclavable.<br />

4 Nasal Endoscope Adult 30 degree 4 mm<br />

• Should have Wide angled field <strong>of</strong> vision.<br />

• Should have 3 types <strong>of</strong> adaptors <strong>for</strong> fiber optic<br />

cable.<br />

• Should have working length <strong>of</strong> 175 mm<br />

• Should be Autoclavable.<br />

5 Nasal Endoscope Pediatric 30 degree 2.7mm<br />

• Should have Wide angled field <strong>of</strong> vision.<br />

• Should have 3 types <strong>of</strong> adaptors <strong>for</strong> fiber optic<br />

cable.<br />

• Should have working length <strong>of</strong> 50 mm<br />

• Should be Autoclavable.<br />

Olympus/Richard<br />

Wolf/Karl<br />

Storz/Maxer/Fujinon<br />

Olympus/Richard<br />

Wolf/Karl<br />

Storz/Maxer/Fujinon<br />

Olympus/Richard<br />

Wolf/Karl<br />

Storz/Maxer/Fujinon<br />

Olympus/Richard<br />

Wolf/Karl<br />

Storz/Maxer/Fujinon


Annexure – 9<br />

Department <strong>of</strong> Laparoscopy & Urology<br />

S.N Technical Specifications <strong>of</strong> Equipment Mfg. Co. Preferred<br />

1 Ureteroscope<br />

Fiber-Uretero-Reno scope, compact 7.5 / 9,8 Fr.<br />

Oval irrigation <strong>and</strong> instrument channel: <strong>for</strong> accessory<br />

instruments <strong>of</strong> max 5 Fr.<br />

Angle <strong>of</strong> view : 12° with <strong>of</strong>fset eyepiece<br />

Distal tip <strong>of</strong> sheath: 8 Fr. WL 425 mm<br />

2 Neonatal/Pediatric Resectoscope<br />

PANOVIEW-Telescope PANOVIEW-Telescope,<br />

diameter 2,7 mm angle <strong>of</strong> view 0°, working length<br />

185 mm with Universal-eyepiece, autoclavable<br />

2. Sheath 12 Fr. with Obturator Cysto- Urethroscope<br />

<strong>for</strong> telescope 2,7 mm, <strong>for</strong> small children<br />

3. Grasping Forcep flexible Flexible grasping <strong>for</strong>ceps<br />

with overload protection <strong>for</strong> Cysto-Urethroscope, 4<br />

Fr., WL 230 mm<br />

4. Sheath 11,5 Fr. with Obturator <strong>for</strong> Resectoscope<br />

with telescope <strong>for</strong> small children<br />

5. Attachment without instrument port <strong>for</strong><br />

Resectoscope with telescope <strong>for</strong> small children<br />

6. Working element passive cutting action <strong>for</strong><br />

Resectoscope with telescope <strong>for</strong> small children<br />

7. Cutting electrode<br />

8. Coagulating electrode<br />

9. HF Monopolar connecting cable<br />

Olympus/Fujinon/ Karl<br />

Storz/Richard Wolf<br />

Olympus/Fujinon/ Karl<br />

Storz/Richard Wolf


Annexure – 10<br />

Department <strong>of</strong> CSSD<br />

S.N Technical Specifications <strong>of</strong> Equipment Mfg. Co. Preferred<br />

1 Drying Machine<br />

Physical characteristics<br />

1. Manufactured in stainless steel AISI 304<br />

2. Temperature control password protected<br />

3. Temperature setting from 1 up to 99 min, or continuous<br />

4. 16 luer lock air connection <strong>for</strong> laparoscopic instruments,<br />

Optional<br />

5. 8 shelves capacity<br />

6. Glass door<br />

7. Lockable door<br />

8. Doors can be configured right or left opening<br />

9. Single <strong>and</strong> double door (pass-through) versions<br />

10. Indirect UV air treatment during the whole cycle Optional<br />

Drying characteristics <strong>and</strong> control<br />

1. One drying circuits double speed <strong>for</strong> cabinet<br />

2. Flashing air flow visual alarm indicators if either drying<br />

circuit fails<br />

3. Air flow alarm with re-settable audible alarm, (flashing<br />

alarm indication remains until the air flow is restored)<br />

4. HEPA filtration on drying circuit<br />

5. Pressure sensors <strong>for</strong> monitoring HEPA filter replacement<br />

6. Indicator on panel advising when HEPA filter replacement<br />

is required<br />

7. Drying temperature settable from ambient to 90ºC<br />

(password protected)<br />

8. Temperature alarms is disabled when door is open, <strong>and</strong><br />

<strong>for</strong> time required to re-equilibrate temperatures in cabinet<br />

after door is closed.<br />

9. Visual indicator to indicate when door is open.<br />

Optional<br />

1. 16 luer lock air connections<br />

2. UV air treatment<br />

TECHNICAL INFORMATION<br />

DIMENSIONS<br />

- Width………approx 710 mm<br />

- Depth …… approx 790 mm<br />

- Height ……approx 1930 mm<br />

- Net weight………approx 190 kg<br />

Tuttaneur / Steridium/<br />

Steelco/ Taxus


CONNECTIONS<br />

- Electric connection…………… 230V/50Hz<br />

Power……………… 2200 W<br />

- Max room temperature admitted……… + 5°C ÷ +40°C<br />

Should carry ISO 13485:2003, ISO 9001:2008, CE, EC <strong>and</strong><br />

should Comply with latest European Guidelines<br />

2 Incubator<br />

1. Interior : approx Size 295 mm X 262 mm X 300<br />

mm.(hxwxd)<br />

2. Exterior: ST Powder coated<br />

3. External Dimensions: approx 620 mm high, 370mm Wide,<br />

420 mm deep.<br />

4. Shelving: (3) Shelf positions (2) shelves supplied.<br />

5. Shelf Spacing : Useable space between shelves 80 mm.<br />

6. Heating: 0.7KW Stainless sheathed element.<br />

7. Control system: Microprocessor control System with large<br />

bright<br />

8. Digital temperature display system incorporates control<br />

9. Failsafe functions.<br />

10. Temperature Range: 50 to 200 Degree C max. (Other<br />

Ranges available).<br />

11. Accuracy: + 0.1 degree C at sensor.<br />

3 Full automatic Ethylene Oxide Sterilizer<br />

This equipment is an ethylene oxide gas sterilizer used <strong>for</strong><br />

the sterilization <strong>of</strong> medical disposables <strong>for</strong> heat sensitive<br />

products like probes, catheters, endoscopes etc. The<br />

chamber <strong>and</strong> all contact parts are made from Stainless Steel<br />

304. It has a single door arrangement with a silicon gasket<br />

<strong>for</strong> leak pro<strong>of</strong> operation.<br />

EQUIPMENT DESCRIPTION<br />

The sterilizer consists <strong>of</strong>:<br />

Chamber: Single door, stainless steel<br />

Chamber Size : 5CFT (140 Ltr)<br />

With Following Systems.<br />

· heating system,<br />

· vacuum system<br />

· humidity system<br />

· 0.2 micron ultra fine air inlet filter,<br />

· programmable controller.<br />

· alphanumeric LCD display<br />

· ENVIRO-PRO system<br />

Steridium /<br />

Charmie/Memmert/<br />

Medicraft Ept.<br />

Taxus/Steridium/3M/<br />

PCI


The chamber as well as the door should made from stainless<br />

steel. The door is provided with a silicon rubber gasket to<br />

ensure leak pro<strong>of</strong> operation.<br />

The entire machinery should housed inside a single cabinet.<br />

Easy access <strong>for</strong> maintenance is obtained by opening the<br />

doors <strong>of</strong> the cabinet the system temperature is selectable<br />

<strong>and</strong> the chamber is electrically heated.<br />

The chamber has a cartridge breaking system, which breaks<br />

the gas-containing cartridge inside the chamber during the<br />

process.<br />

The electrical <strong>and</strong> electronic control <strong>and</strong> indicating<br />

equipment should housed in the same cabinet. Audiovisual<br />

indication <strong>and</strong> a powerful <strong>and</strong> sturdy microprocessor ensure<br />

reliable <strong>and</strong> safe operation every time; <strong>and</strong> in case <strong>of</strong> fault<br />

provide the operator with correct in<strong>for</strong>mation regarding the<br />

fault.<br />

Control Facility:<br />

The Machine should provide two types <strong>of</strong> controls <strong>for</strong> our<br />

sterilizer: Automatic as well as Manual<br />

In AUTO MODE :<br />

In AUTO mode , the sterilization is a one – touch operation ;<br />

where the operator loads the material in the trolley provided<br />

along with<br />

the machine , closes the door <strong>and</strong> then presses the Start<br />

button to initiate the cycle; the cycle then its own <strong>and</strong> after<br />

sterilizing <strong>and</strong> aerating the load; in<strong>for</strong>ms the operator that<br />

the cycle is complete.<br />

The sterilizer automatically per<strong>for</strong>ms all stages <strong>of</strong><br />

sterilization treatment using ethylene oxide, with control <strong>of</strong><br />

the essential parameters:<br />

· vacuum / pressure / humidification / contact time<br />

(exposure period) / chamber temperature / aeration <strong>of</strong><br />

load<br />

In MANUAL MODE :<br />

In case <strong>of</strong> un<strong>for</strong>eseen problems occurring in the machine,<br />

there is a provision to changeover from AUTO mode to<br />

MANUAL mode; <strong>for</strong> operating the machine in Manual Mode.<br />

A separate set <strong>of</strong> operating switches are provided to enable<br />

the operator to take a cycle in manual mode also.<br />

Display & Printouts<br />

The alphanumeric green display shows the various cycle<br />

statuses <strong>and</strong> displays the current time, the date, the batch<br />

no., the time remaining in Gas exposure phase, the time<br />

remaining in the Aeration phase. Besides this the display also<br />

shows the various parameters, <strong>and</strong> the actual error <strong>and</strong> also<br />

the error code as <strong>and</strong> when applicable.


The printer indicates the various parameters like the Start<br />

time, End time, Date, the batch no. <strong>and</strong> the operator’s ID<br />

mark, errors <strong>and</strong> error codes, the various parameters, Gas<br />

exposure time, Aeration Time as <strong>and</strong> when applicable.<br />

Safety Features:<br />

·All sensors linked to the automation ensure reliability <strong>and</strong><br />

failsafe operation.<br />

·Every cycle there is a Leak test period; which checks the<br />

leakage <strong>and</strong> aborts the cycle if there is a leakage in the<br />

system.<br />

·Locked door sensor during cycle<br />

·Constant watch over entries <strong>and</strong> break diagnostic from<br />

automation, which warns the operator, by means <strong>of</strong><br />

messages on indicator <strong>and</strong> buzzer.<br />

·Cycle completion record is shown on the printout.<br />

·Auto - Abort facility in case <strong>of</strong> abnormal conditions.<br />

·Three degassing cycles, be<strong>for</strong>e aeration starts, to enhance<br />

removal <strong>of</strong> residual EO.<br />

Special Features<br />

·Stainless steel chamber <strong>and</strong> fittings.<br />

·Special easily operable flat door with interlock <strong>for</strong> added<br />

safety.<br />

·Evacuation <strong>of</strong> chamber during washing cycle <strong>and</strong> aeration is<br />

programmable.<br />

·Auto – Manual Changeover possible in case <strong>of</strong> failure <strong>of</strong><br />

auto system.<br />

·Password Protection to change <strong>of</strong> instructions.<br />

Disposable Items:<br />

1. ETO Cartridge – 10 Nos.<br />

2. Sterie Roll – 5cm, 7.5cm, 10cm, 15cm, 20cm,& 25cm. – 2<br />

each<br />

4 Auto Control Panel <strong>for</strong> Autoclave (two nos.)<br />

• st<strong>and</strong>ard plc control system based on the hi-tech<br />

state <strong>of</strong> the art micro-processor circuit technology,<br />

ensuring a complete automatic operations along with<br />

high efficiency <strong>and</strong> great reliability.<br />

• 100% automatic operation throughout the sterilization<br />

cycle <strong>of</strong> both the horizontal autoclave ( Surgikraft &<br />

Medicare Eqpt. make).<br />

• No intermediary human intervention should be<br />

required after choosing the parameters <strong>and</strong> initiating<br />

the sterilization process in the autoclaves..<br />

• The primary cycle phase <strong>and</strong> the actual parameters <strong>of</strong><br />

the horizontal autoclave <strong>and</strong> along with set values<br />

should be displayed on the LCD panel during the entire<br />

cycle progress.<br />

Modi /Shrijee Surgical


• The main parameters <strong>of</strong> the process such as,<br />

temperature, pressure, time should be controlled <strong>and</strong><br />

displayed, on the LCD panel <strong>of</strong> the system.<br />

• Ergonomically designed keyboard located on the front<br />

level should enable the user to choose the desired<br />

program, initiate <strong>and</strong> terminate the cycle, <strong>and</strong> allow a<br />

trained technician to preset the main parameters using<br />

an access code.<br />

• Easy to use, user friendly <strong>and</strong> fully programmable.<br />

• For a elaborate <strong>and</strong> presentable documentation <strong>of</strong><br />

cycle process, the logic control unit should be<br />

provided with a diligent wipro/epson dot matrix<br />

printer, which is connected to the central<br />

microprocessor system.. The printer should generate<br />

a hard copy <strong>of</strong> the printout <strong>of</strong> the relevant or<br />

desired in<strong>for</strong>mation relating to the cycle operation like<br />

the pressure , sterilization time, temperature at any<br />

given/preset time interval, vacuum, <strong>and</strong> drying time,<br />

number <strong>of</strong> cycles, number <strong>of</strong> pulsing etc.<br />

• The PLC control system is designed to operate up to six<br />

st<strong>and</strong>ard sterilization programs between 105oC <strong>and</strong><br />

137oC <strong>and</strong> two test programs optional <strong>and</strong> selectable<br />

through keyboard on the panel. Other parameters such<br />

as air removal, sterilization <strong>and</strong> drying stages should be<br />

programmable.<br />

• Fully Automatic operation; cycle begins by press <strong>of</strong> the<br />

START button.<br />

• Initial air purging cycle; at the beginning air is<br />

automatically removed from the chamber.<br />

• Microprocessor based Digital Temperature Indicator<br />

Controller. Controls temperature / pressure precisely<br />

at set value.<br />

• In built adjusted digital timer; programmable as per<br />

sterilization load requirement.<br />

• Automatic steam exhaust at the end <strong>of</strong> cycle.<br />

• Unique microprocessor temperature controller<br />

provides facility to program the cycle, with a feather<br />

touch panel.<br />

• Auto control Panel with LCD Display<br />

• Shows Down Times<br />

• Display <strong>of</strong> Status<br />

• Easy setting <strong>of</strong> Six type <strong>of</strong> different Programs in six<br />

different temperature<br />

• 10 Memory Save Cycle<br />

• Online printing & Self-Temperature setup.


Annexure – 11<br />

Department <strong>of</strong> General OPD & Wards<br />

S.N Technical Specifications <strong>of</strong> Equipment Mfg. Co. Preferred<br />

1 Fogging Machine<br />

Specifications:<br />

• Tank Capacity: 7.5 ltrs (HDPE – Engg. Plastic grade non<br />

corrosive).<br />

• Tank with graduated marking <strong>and</strong> liquid level visibility<br />

from outside. Range from 1 litre ~ 7.5 litres in step <strong>of</strong><br />

0.5 litres.<br />

• With Attached “Electronic Timer Device” to run <strong>for</strong> 60<br />

mins. in absence <strong>of</strong> attender.<br />

• Aluminium Power Head Housing corrosion resistant &<br />

SS304 fittings.<br />

• Nozzle Assembly: Non rotating, Non clogging & Vortex<br />

design.<br />

• Liquid line connectors/Strainers & Wire mesh SS 304.<br />

• Air-Filter with attached rubber ring & SS clamp.<br />

• Area coverage: Upto 10,000 cu. fts.<br />

• Liquid discharge rate: 0 ~ 300 ml/min. (Adjustable with<br />

“Flow Control Mechanism).<br />

• Volume <strong>of</strong> Airflow: 3.00 ~ 4.00 cubic mtr/min.<br />

• Pressure Clamp <strong>and</strong> leak pro<strong>of</strong> fittings.<br />

• Reach: > 10 mtrs distance & > 5 mtrs height.<br />

• Particle Size: 1 ~ 40 microns (Adjustable with “Flow<br />

Control Mechanism”).<br />

• Rotating Knob: Available in SS 304 & Plastic Make.<br />

• 230 volts / 50 Hz. AC current.<br />

• Motor speed: 20,000 RPM.<br />

• Motor Type: High Thrust Double Stage/Impellor motor<br />

with Class B insulation, inbuilt circuit <strong>for</strong> thermal<br />

overload protection.<br />

• Motor CFM: 105 Cubic Fts/min.<br />

• Motor Rating: 120 minutes.<br />

• 7 Kgs. Light weight <strong>and</strong> portable.<br />

• All fitting components SS304 only.<br />

• Spares: Extra Air Filter.<br />

Galtron/J&J/PCI/<br />

Radiant/Idealine/Skan/<br />

Aspee


2 Nebulizer<br />

•With V.V.T. (Virtual Valve Technology) nebulizer kit, <strong>for</strong><br />

efficient delivery <strong>of</strong> medication<br />

•without silicon valve<br />

•High Nebulization rate ensuring optimized treatment<br />

duration<br />

•Leaves minimal residual medication<br />

•Easy to operate <strong>and</strong> maintain, with easy-to-clean<br />

Nebulizer kit without silicon valves<br />

V.V.T. Nebulizer kit- 2 Nos.<br />

3 Fetal Doppler<br />

1. Doppler should display beat to beat measurement <strong>of</strong> FHR <strong>of</strong><br />

Foetus & Adult.<br />

2. It Should have 1 TRANDUCERS Clinical H<strong>and</strong> Probe <strong>of</strong> Plastic<br />

body with Crystal <strong>and</strong> Metal H<strong>and</strong>le.<br />

3. Individually adjustable Bradycardia/Tachycardia FHR limits<br />

with audio /visuals Alarms.<br />

4. Alarms Silence Facility.<br />

5. On power OFF alarms settings should remain unchanged.<br />

6. It should have facility to measure Foetal & adult heart rate.<br />

7. It should have clamp <strong>for</strong> holding the transducer probe.<br />

8. Mains as well as battery operated.<br />

9. Feather touch key operated volume control.<br />

10. Highly sensitive ultrasonic beam permits hearing the Foetal<br />

heart beats clearly from 10-12th week <strong>of</strong> pregnancy.<br />

11. The output can be presented in two different ways:<br />

a. Built in speaker b. Display readout<br />

12. Compact, lightweight, portable ABS cabinet.<br />

Applications:<br />

Detection <strong>of</strong> foetal heart at 10 to 12 weeks<br />

Localization <strong>of</strong> Placenta.<br />

Detects Foetal Distress & Intrauterine death.<br />

Determine multiple pregnancies<br />

Accessories:<br />

Transducer Probe with cable, Oil Bottle<br />

Carrying case, Mains Adaptor<br />

Technical Specifications:<br />

1] Body: Shock pro<strong>of</strong><br />

2] Battery: 6 X 1.5 v D size<br />

3] Mains adaptor<br />

4] Frequency: 2 MHz<br />

5] Weight: 1kg<br />

Omron/Nulife/<br />

Morepen/Philips<br />

Galtron/BPL/Teksonic


4 Electric Needle Destroyer<br />

With Needle Cutting <strong>and</strong> cap burning facility<br />

5 Electric Suction Machine LIPO fully stainless steel body<br />

Rotary High-Vac are double stage pumps <strong>of</strong> larger capacities,<br />

which are known as Lipo <strong>for</strong> fats extraction <strong>and</strong> full in cosmetics<br />

surgery, the main assembly <strong>of</strong> the pump consist <strong>of</strong> a stator with<br />

a rotor mounted eccentrically in it. The rotor is fitted with two<br />

spring loaded diametrically opposed vanes, which move in <strong>and</strong><br />

out <strong>of</strong> their slots pressing against the inner surface <strong>of</strong> the stator<br />

these are oil sealed self lubricated, silent running, it is designed<br />

to achieve maximum vacuum in a very short time, it reduce the<br />

wear <strong>and</strong> tear <strong>of</strong> its components <strong>and</strong> makes it suitable <strong>for</strong><br />

noiseless <strong>and</strong> trouble free per<strong>for</strong>mance <strong>for</strong> years <strong>and</strong> thus helps<br />

in reduction <strong>of</strong> repair bills, these are very compact but so simple<br />

in design that all minor repairs in case <strong>of</strong> need can be carried<br />

out easily, it run continuously <strong>for</strong> many hours at a time. The<br />

entire pump <strong>and</strong> motor are placed in an attractive solid<br />

STAINLESS STEEL cabinet having steel top, which is giving extra<br />

protection, reduces heat noise <strong>and</strong> vibration to the minimum<br />

the suction mechanism is oil immersed. The unit is mounted on<br />

smooth moving ball bearing heavy-duty castors, <strong>and</strong> noiseless. It<br />

crates vacuum <strong>of</strong> 700 to 760mm <strong>of</strong> Hg (28” to 30”) the suction<br />

system is accurately controlled <strong>and</strong> precisely regulated by knob<br />

this unit is fitted with filter <strong>and</strong> automatic cut <strong>of</strong>f by float<br />

mechanism, vacuum gauge, pilot light <strong>and</strong> protection fuse, this<br />

unit is fitted with 1/2HP ball bearing double shaft motor<br />

working on 220-250V single phase 50cycle Suction Capacity:<br />

25Lts /p minutes Max Vacuum: 700mm to 760mm <strong>of</strong> Hg<br />

Consumption: ½ HP Voltage: 220 V 50 Cycles Castors: 5cm<br />

Antistatic Weight: Approx 43kg Dimensions: 38cmx38cmx85cm<br />

with castor Sound: almost whispers Finish: SS cabinet Suction<br />

Jar: 2nos 2500ml with over flow safety device<br />

6 Autoprocessor<br />

1. should process sheet films.<br />

2. film size min-4x4 ad max 14x17.<br />

3. Tank volume 5litres.<br />

4.Developer temp 30 to 37 deg adjustable<br />

5. fixer temp 30 to 37 deg adjustable.<br />

6. Direr temp 70 deg max.<br />

7. Replenishment tanks-25 litres.<br />

8. Facility <strong>for</strong> anti crystallization ad anti oxidation<br />

programme.<br />

9. it should have international st<strong>and</strong>ards ad safety<br />

requirements.<br />

10. should be light weight 40 to 50 kgs.<br />

11. dimension app:80cmsx60x44 or less.<br />

12.heat emission should be less than1.5kj/sec<br />

Omron/Nulife/Metco/<br />

Mehta Surg.<br />

Brightlite/Supreme/<br />

Hira/Galtron/SPI/<br />

An<strong>and</strong><br />

Chhayagraphics/<br />

Prognosys <strong>Medical</strong>


13. power consumption less than 1.5kwh during<br />

processing.<br />

14. auto manual filling <strong>of</strong> chemicals.<br />

15chemical circulation continuous.<br />

16film in feed by detection switch.<br />

17. Processing time100/167 sec.<br />

18. Special requirements: manufactures ad suppliers<br />

should have own manufacturing unit in India with good<br />

service backup.<br />

Company should have iso9001 st<strong>and</strong>ards <strong>and</strong> CE<br />

certification also.<br />

19. Machine should have two piece body shell.


Annexure – 12<br />

Solar Water Heater System<br />

Sr.<br />

No.<br />

Description Quantity*<br />

1.<br />

Labor room/NICU<br />

Solar water heating system<br />

Capacity 1500 liters per day<br />

1 no.<br />

2. Cold water hdpe tank capacity 1000 ltrs isi<br />

1 no.<br />

3 St<strong>and</strong> <strong>for</strong> cold water tank<br />

1 no.<br />

4 Cold water piping gi b class / kitec<br />

20 mtrs<br />

5 Hot water piping<br />

Gi b class / kitec<br />

Insulation: rockwool 48 kg/ cum aluminium<br />

cladding<br />

35mtrs<br />

6 Electrical backup tank capacity: 500 liters with<br />

control panel<br />

Gynecology ward<br />

1 no.<br />

1. Solar water heating system<br />

Capacity 2500 liters per day<br />

1 no.<br />

2. Cold water hdpe tank capacity 500 ltrs isi<br />

1 no.<br />

3 St<strong>and</strong> <strong>for</strong> cold water tank 1 no.<br />

4 Cold water piping gi b class / kitec<br />

22 mtrs<br />

5 Hot water piping<br />

Gi b class / kitec<br />

Insulation: rockwool 48 kg/ cum aluminium<br />

cladding<br />

45 mtrs<br />

6 Electrical backup tank capacity: 500 liters with<br />

control panel<br />

Surgical/OT<br />

1 no.<br />

1. Solar water heating system<br />

Capacity 800 liters per day<br />

1 no.<br />

2. Cold water hdpe tank capacity 500 ltrs isi<br />

1 no.<br />

3 St<strong>and</strong> <strong>for</strong> cold water tank 1 no.


4 Cold water piping gi b class / kitec<br />

5 Hot water piping<br />

Gi b class / kitec<br />

Insulation: rockwool 48 kg/ cum aluminium<br />

cladding<br />

6 Electrical backup tank capacity: 250 liters with<br />

control panel<br />

Deluxe/Male medical ward<br />

1. Solar water heating system<br />

Capacity 3000 liters per day<br />

20 mtrs<br />

30mtrs<br />

1 no.<br />

1 no.<br />

2. Cold water hdpe tank capacity 500 ltrs isi<br />

3 St<strong>and</strong> <strong>for</strong> cold water tank<br />

1 no.<br />

1 no.<br />

4 Cold water piping gi b class /kitec<br />

30 mtrs<br />

5 Hot water piping<br />

Gi b class / kitec<br />

Insulation: rockwool 48 kg/ cum aluminium<br />

cladding<br />

94 mtrs<br />

6 Electrical backup tank capacity: 500 liters with<br />

1 no.<br />

control panel<br />

Pediatric/ orthopedic/Female medical<br />

1. Solar water heating system<br />

Capacity 2500 liters per day<br />

1 no.<br />

2. Cold water hdpe tank capacity 500 ltrs isi<br />

3 St<strong>and</strong> <strong>for</strong> cold water tank<br />

1 no.<br />

1 no.<br />

4 Cold water piping gi b class<br />

30 mtrs<br />

5 Hot water piping<br />

Gi b class<br />

Insulation: rockwool 48 kg/ cum aluminium<br />

cladding<br />

90 mtrs<br />

6 Electrical backup tank capacity: 500 liters with<br />

1 no.<br />

control panel<br />

Trauma<br />

1. Solar water heating system<br />

Capacity 800 liters per day<br />

2. Cold water hdpe tank capacity 500 ltrs isi<br />

1 no.<br />

1 no.


3 St<strong>and</strong> <strong>for</strong> cold water tank 1 no.<br />

4 Cold water piping gi b class /kitec<br />

20 mtrs<br />

5 Hot water piping<br />

Gi b class / kitec<br />

Insulation: rockwool 48 kg/ cum aluminium<br />

cladding<br />

45 mtrs<br />

6 Electrical backup tank capacity: 250 liters with<br />

control panel<br />

1 no.<br />

*The above quantities are approximate <strong>and</strong> hence may differ slightly at the<br />

time <strong>of</strong> installation which will be under the scope <strong>of</strong> the successful bidder.<br />

SCOPE OF WORK:<br />

A) Supply & installation <strong>of</strong> solar collectors on flat surface.<br />

B) Supply & installation <strong>of</strong> insulated hot water tank <strong>of</strong> mentioned<br />

capacity.<br />

C) Supply & installation <strong>of</strong> system piping.<br />

D) System designing.<br />

E) Testing & commissioning <strong>of</strong> the system.


Annexure – 13<br />

General Instruments<br />

Sr. No Particulars Total Mfg Company<br />

1 Needle Holder 8" 112<br />

2 Needle Holder 6" 127<br />

3 Needle Holder 4" 20<br />

4 Needle Holder 10" 15<br />

5 Gauze Cutting Scissor 35<br />

6 Artery <strong>for</strong>cep(curved)6' 243<br />

7 Cockers 8" 40<br />

8 S.S Drum12*15 50<br />

9 S.S Drum10*9 55<br />

10 S.S Drum10*5 24<br />

11 Tooth Forcep6" 110<br />

12 Sponge Holder 8" 118<br />

13 Speculum 20<br />

14 S.S tray 12*8" 63<br />

15 S.S tray 9*6" 40<br />

16 S.S tray 12*10" 25<br />

17 Enema set 3<br />

18 x-ray Hanger12*15" 30<br />

19 x-ray Hanger11*15" 30<br />

20 x-ray Hanger10*12" 30<br />

21 x-ray Hanger10*8" 30<br />

22<br />

x-ray Devloping tank cover,22.5<br />

ltr<br />

3<br />

23 Mayo scissor 8" 89<br />

24 Mayo scissor 6" 35<br />

25 Mosquito artery curved 4" 97<br />

26 Scoop 19<br />

27 Suture cutting scissor 38<br />

28 Skin stappler remover 14<br />

29 s. s Bowl small 201<br />

30 s. s Bowl 4" diameter 55<br />

31 Metzen bone scissor straight 20<br />

32 b.p. h<strong>and</strong>le No. 3 27<br />

33 b.p. h<strong>and</strong>le No. 4 25<br />

34 mosquito artery straight 4" 35<br />

35 Allies 6" 95


Sr. No Particulars Total Mfg Company<br />

36 Allies 4" 20<br />

37 Hammer 11<br />

38 paed. Ambu bag 1 Liter 7<br />

39 Adson tooth <strong>for</strong>ceps 22<br />

40 E.T Tube stilet (adult) 32<br />

41 laryngoscope bulb 65<br />

42 Bipap mask( adult) 3<br />

Portabale ventilator circuit-<br />

Double Water Trap<br />

1<br />

43 (Autoclavable)<br />

44 linen trolley 1<br />

45 mayo trolley four rails big 1<br />

46 F.B.Hook 2<br />

47 Hookson Hook 1<br />

48 Fine Scissor 20<br />

49 Tuff scissor 10<br />

50<br />

Tracheostomy set (single<br />

puncture)<br />

51 Bone holding <strong>for</strong>cep(humerous)<br />

2<br />

52 Bone holding <strong>for</strong>cep(tibia) 1<br />

53 Bone holding <strong>for</strong>cep(Femur) 2<br />

54 Flexible fix head reamer no. 11<br />

1<br />

55 O2 Mask paed 5<br />

56<br />

laparoscopic trocar<br />

(versapotNo.10)<br />

2<br />

57<br />

laparoscopic trocar<br />

(versapotNo.12)<br />

2<br />

58 Maril<strong>and</strong> 2<br />

59 Laparoscopic bap Cock 4<br />

60 Laparoscopic alliz 2<br />

61 Monopolar cautry cord 50<br />

62 Bipolar Cautry (curved point) 2<br />

63 Formalin chamber big 2<br />

64 Formalin chamber smol 2<br />

65<br />

H<strong>and</strong> reamer 8 to 13<br />

(tibia/Femur)<br />

53<br />

1 set<br />

66 H<strong>and</strong> reamer 4 to 7 (Humurous)<br />

1set<br />

67 Punch 3


Sr. No Particulars Total Mfg Company<br />

68 Periosteum Small 2<br />

69 Periosteum Small Curved 2<br />

70 Periosteum Large 2<br />

71<br />

Intestinal clamp non crushing<br />

curved<br />

6<br />

72<br />

Intestinal clamp non crushing<br />

straigst<br />

6<br />

73 Bur per<strong>for</strong>ator <strong>for</strong> cramiotimy 1 set<br />

74 Reservoir bag 2 Ltr 5<br />

75 Reservoir bag 2.5 Ltr 5<br />

76 Turp loop (indian) 10<br />

77 Bain circuit <strong>for</strong> troley 5<br />

78 JRO circurt Paed 2<br />

79 Retrograbe Dialator 1<br />

80 Uretic cathetor fr. 3,4,5 2 each<br />

81 Double D. J .Stent Fr 3,4,5 2 each<br />

82 Sclero Therapy Needle 10<br />

83 Plier 5<br />

84<br />

Nibbler (Rounger) 30 Degree<br />

Bent<br />

5<br />

85 Nibbler (Rounger) Straigst 5<br />

86 Nibbler (Rounger) Large 5<br />

87 Nibbler (Rounger) Small 5<br />

88 Man Man Key 10<br />

89 Awl <strong>for</strong> tibia 2<br />

90 Awl <strong>for</strong> femur 2<br />

91 Awl Long H<strong>and</strong>el For femur 1<br />

92 Awl For Radius 2<br />

93 Blunt Disscetor 5<br />

94 Hammer <strong>for</strong> Ortho Small 2<br />

95 Hammer <strong>for</strong> Ortho Midium 2<br />

96 Hammer <strong>for</strong> Ortho heavy 2<br />

97 Homan Retractor 2 set<br />

98 T.H<strong>and</strong>le For K-Wire 5<br />

99 H<strong>and</strong> Dril 1<br />

100 Shanez Pin T. h<strong>and</strong>le 2<br />

101 Uterin Holding <strong>for</strong> ceps 3<br />

102 Deavers Medium Sige 5<br />

103 Tongue Deprassor 12<br />

104 Fistila Probe 5<br />

105 Mixtard 3 Pair


Sr. No Particulars Total Mfg Company<br />

106 Suprapubic Trocher 2<br />

107 Suctiom Tip Multipores 4 To 1<br />

2 Set<br />

108<br />

Scissor For Plastic Suragiry<br />

3"(metzenbaum)<br />

5<br />

109 Towel Clip 65<br />

110 Cannulated Screw Driver 4.5 2<br />

111 Cannulated Dril Bit 6.5 3<br />

112 Bone Marrow Needle no. 16 S.S<br />

113<br />

Small Size Spike For<br />

R/U/Humerous<br />

2 Set<br />

114<br />

Plate Holding Forceps<br />

R/U/Humerous<br />

1 Set<br />

115 Proseal LMA No. 3-4 2 Each<br />

116<br />

Combined Spinal 27G Epidural<br />

Needle16 G<br />

20<br />

117 Epidural needle 16G 10<br />

118 Epidural Catheter No.16 20<br />

119 Cord Holding For ceps 4<br />

Non scalpal Vasectomy NSV Hook 4 Each<br />

120 Vas Holding Forceps<br />

121 AO Drill Bit 3.5 3<br />

122 AO Drill Bit 4.5 3<br />

123 AO Drill Bit 2.5 3<br />

124 Counter synk 3.5 1<br />

125 Counter synk 4.5 1<br />

126 Acetabulum Retractor (all Sizes)<br />

127<br />

Wire cutter (Tumy Sleeve tip) For<br />

2 mm<br />

128<br />

Wire cutter (Tumy Sleeve tip) For<br />

5 mm<br />

1<br />

129 AO Tap 3.5 mm 1<br />

130 AO Tap 4.5 mm 1<br />

131<br />

Dissecting sleeve With Tumy<br />

Sleeve Tip<br />

3<br />

132 Bone Cutter Small 2<br />

133 Bone Cutter Heavy 2<br />

20<br />

1<br />

1


Sr. No Particulars Total Mfg Company<br />

134<br />

Osteotome set All Sizes With<br />

Wooden H<strong>and</strong>le (AO)<br />

1<br />

135 Adaptor For Suction (Steel) 2<br />

136 IDL Mirror 4<br />

137 Siegels Pneumetic Speculum 2<br />

138 T Elevator 8<br />

139 Mouth Mirror 45<br />

140 Upper Anterior <strong>for</strong>ceps 10<br />

141 Third Molar Forceps 9<br />

142 Hockey stick (Dental) 7<br />

143 Mouth Gag 3<br />

144 Magles <strong>for</strong>cep 6<br />

145 Nasal Speculun 5<br />

146 Plastic kidney tray (blue) 148<br />

147 IOL Manipulater( Blunt edge) 4<br />

148 Lim's tooth Forceps 5<br />

149 Plain <strong>for</strong>ceps (Opthalmic) 5<br />

150 Wire Vectis 4<br />

151 Phaco Choppper Sharp end 1<br />

152 Tunnel Knife 50<br />

153 Phaco Sleeve 5<br />

154 Phaco Tubing Set 2<br />

155 Keratoplasty set 1<br />

156 Diamond knipe 1<br />

157 Endocapsuler Tension Rings 10<br />

158 Iris Hook (self Retaining) 4<br />

159 Silicon Sling <strong>for</strong> Ptosis 5<br />

160 Rhexcis Forceps 2<br />

161 Vitrectomy cutter 1<br />

162 Glass Syringe 10 ml,5ml,2ml 20 each<br />

163 AC Maintainer 5<br />

164<br />

165<br />

V P Shunt Introducer (Adult)<br />

All Size<br />

V P Shunt Introducer (Paed)<br />

All Size<br />

Preferred Manufacturing Company is mentioned by the department on<br />

Schedule <strong>of</strong> Requirement, Specification <strong>and</strong> allied technical Details.<br />

1<br />

1


Annexure – 14<br />

(FORMAT OF AUTHORIZATION LETTER FOR AUTHORIZED<br />

DISTRIBUTOR)<br />

I / We hereby declare that....<br />

1. M/s.<br />

________________________________________________________________<br />

___is our authorized distributor <strong>for</strong> our products in India from date <strong>and</strong> they<br />

are authorized to quote <strong>and</strong> follow up on our behalf <strong>and</strong> the said agreement is<br />

valid in <strong>for</strong>ce as on date;<br />

2. I/We undertake to supply the drugs / items <strong>for</strong> which the quotations <strong>of</strong><br />

following items are submitted by<br />

M/s.__________________________________________on our behalf in<br />

respect <strong>of</strong> <strong>Tender</strong> Enquiry # :___________________________<br />

Sr.No. Item No. Name <strong>of</strong> Item<br />

(1)<br />

(2)<br />

3. I / We have read all the terms <strong>and</strong> conditions <strong>of</strong> the tender enquiry <strong>and</strong> the<br />

same are irrevocably binding upon us till the expiry <strong>of</strong> the contract signed &<br />

executed on our behalf;<br />

4. I/We shall notify the <strong>Medical</strong> Superintendent, Shree Vinoba Bhave Civil<br />

Hospital, Silvassa. immediately if there is any change in the agreement<br />

between M/s. _____________________________<strong>and</strong> me/us regarding<br />

authorized distributorship <strong>of</strong> our products <strong>and</strong> further undertake to supply the<br />

items quoted by the distributor on my / our behalf at the quoted in the tender<br />

enquiry in case <strong>of</strong> such a change <strong>of</strong> agreement.<br />

5. This authority is applicable only <strong>for</strong> <strong>Tender</strong> Enquiry <strong>of</strong> Shree Vinoba Bhave<br />

Civil Hospital, Silvassa. Annual E <strong>Tender</strong> <strong>for</strong> Year 2012-13 due on<br />

______________.<br />

Date:-<br />

Signature <strong>of</strong> Authorized Signatory


Annexure - 15<br />

Specifications <strong>of</strong> <strong>Medical</strong> <strong>Equipments</strong> <strong>for</strong> Department <strong>of</strong><br />

__________________________________________<br />

(Department name to be filled by the bidder)<br />

S.N Name <strong>of</strong><br />

Equipment<br />

Mfg<br />

Company<br />

Preferred<br />

Mfg<br />

Company<br />

quoted<br />

Y/N/D Deviation if any


Annexure – 16<br />

Price Schedule <strong>of</strong> Solar Water Heater System<br />

Sr.<br />

No.<br />

Description<br />

Labor room/NICU<br />

Quantity* Unit Rate<br />

1. Solar water heating system<br />

Capacity 1500 liters per day<br />

1 no.<br />

2. Cold water hdpe tank capacity 1000 ltrs<br />

isi<br />

1 no.<br />

3 St<strong>and</strong> <strong>for</strong> cold water tank<br />

1 no.<br />

4 Cold water piping gi b class / kitec<br />

20 mtrs<br />

5 Hot water piping<br />

Gi b class / kitec<br />

Insulation: rockwool 48 kg/ cum<br />

aluminium cladding<br />

35mtrs<br />

6 Electrical backup tank capacity: 500 1 no.<br />

liters with control panel<br />

1.<br />

Gynecology ward<br />

Solar water heating system<br />

Capacity 2500 liters per day<br />

1 no.<br />

2. Cold water hdpe tank capacity 500 ltrs<br />

isi<br />

1 no.<br />

3 St<strong>and</strong> <strong>for</strong> cold water tank 1 no.<br />

4 Cold water piping gi b class / kitec<br />

22 mtrs<br />

5 Hot water piping<br />

Gi b class / kitec<br />

Insulation: rockwool 48 kg/ cum<br />

aluminium cladding<br />

45 mtrs<br />

6 Electrical backup tank capacity: 500<br />

liters with control panel<br />

Surgical/OT<br />

1 no.<br />

1. Solar water heating system<br />

Capacity 800 liters per day<br />

1 no.<br />

2. Cold water hdpe tank capacity 500 ltrs<br />

isi<br />

1 no.<br />

3 St<strong>and</strong> <strong>for</strong> cold water tank 1 no.


4 Cold water piping gi b class / kitec<br />

20 mtrs<br />

5 Hot water piping<br />

Gi b class / kitec<br />

Insulation: rockwool 48 kg/ cum<br />

aluminium cladding<br />

30mtrs<br />

6 Electrical backup tank capacity: 250<br />

liters with control panel<br />

Deluxe/Male medical ward<br />

1 no.<br />

1. Solar water heating system<br />

Capacity 3000 liters per day<br />

1 no.<br />

2. Cold water hdpe tank capacity 500 ltrs<br />

isi<br />

1 no.<br />

3 St<strong>and</strong> <strong>for</strong> cold water tank 1 no.<br />

4 Cold water piping gi b class /kitec<br />

30 mtrs<br />

5 Hot water piping<br />

Gi b class / kitec<br />

Insulation: rockwool 48 kg/ cum<br />

aluminium cladding<br />

94 mtrs<br />

6 Electrical backup tank capacity: 500<br />

liters with control panel<br />

Pediatric/ orthopedic/Female medical<br />

1 no.<br />

1. Solar water heating system<br />

Capacity 2500 liters per day<br />

1 no.<br />

2. Cold water hdpe tank capacity 500 ltrs<br />

isi<br />

1 no.<br />

3 St<strong>and</strong> <strong>for</strong> cold water tank 1 no.<br />

4 Cold water piping gi b class<br />

30 mtrs<br />

5 Hot water piping<br />

Gi b class<br />

Insulation: rockwool 48 kg/ cum<br />

aluminium cladding<br />

90 mtrs<br />

6 Electrical backup tank capacity: 500<br />

liters with control panel<br />

Trauma<br />

1 no.<br />

1. Solar water heating system<br />

Capacity 800 liters per day<br />

1 no.<br />

2. Cold water hdpe tank capacity 500 ltrs<br />

isi<br />

1 no.


3 St<strong>and</strong> <strong>for</strong> cold water tank 1 no.<br />

4 Cold water piping gi b class /kitec<br />

20 mtrs<br />

5 Hot water piping<br />

Gi b class / kitec<br />

Insulation: rockwool 48 kg/ cum<br />

aluminium cladding<br />

45 mtrs<br />

6 Electrical backup tank capacity: 250<br />

liters with control panel<br />

1 no.<br />

The total Cost <strong>of</strong> the Solar water Heater Plant is<br />

___________________(in figures)<br />

___________________________________________________________<br />

__________________________________________________(in words)<br />

The above cost includes all the installation, commissioning,<br />

transportation <strong>and</strong> training charges. No other charges will be borne by<br />

the Hospital other than the rates mentioned above.<br />

Signature:<br />

Stamp:


Annexure – 17<br />

Price Schedule <strong>for</strong> General Instruments<br />

Sr. No Particulars Total Unit Rate Total<br />

1 Needle Holder 8" 112<br />

2 Needle Holder 6" 127<br />

3 Needle Holder 4" 20<br />

4 Needle Holder 10" 15<br />

5 Gauze Cutting Scissor 35<br />

6 Artery <strong>for</strong>cep(curved)6' 243<br />

7 Cockers 8" 40<br />

8 S.S Drum12*15 50<br />

9 S.S Drum10*9 55<br />

10 S.S Drum10*5 24<br />

11 Tooth Forcep6" 110<br />

12 Sponge Holder 8" 118<br />

13 Speculum 20<br />

14 S.S tray 12*8" 63<br />

15 S.S tray 9*6" 40<br />

16 S.S tray 12*10" 25<br />

17 Enema set 3<br />

18 x-ray Hanger12*15" 30<br />

19 x-ray Hanger11*15" 30<br />

20 x-ray Hanger10*12" 30<br />

21 x-ray Hanger10*8" 30<br />

22<br />

x-ray Devloping tank cover,22.5<br />

ltr<br />

3<br />

23 Mayo scissor 8" 89<br />

24 Mayo scissor 6" 35<br />

25 Mosquito artery curved 4" 97<br />

26 Scoop 19<br />

27 Suture cutting scissor 38<br />

28 Skin stappler remover 14<br />

29 s. s Bowl small 201<br />

30 s. s Bowl 4" diameter 55<br />

31 Metzen bone scissor straight 20<br />

32 b.p. h<strong>and</strong>le No. 3 27<br />

33 b.p. h<strong>and</strong>le No. 4 25<br />

34 mosquito artery straight 4" 35<br />

35 Allies 6" 95


Sr. No Particulars Total Unit Rate Total<br />

36 Allies 4" 20<br />

37 Hammer 11<br />

38 paed. Ambu bag 1 Liter 7<br />

39 Adson tooth <strong>for</strong>ceps 22<br />

40 E.T Tube stilet (adult) 32<br />

41 laryngoscope bulb 65<br />

42 Bipap mask( adult) 3<br />

Portabale ventilator circuit-<br />

Double Water Trap<br />

1<br />

43 (Autoclavable)<br />

44 linen trolley 1<br />

45 mayo trolley four rails big 1<br />

46 F.B.Hook 2<br />

47 Hookson Hook 1<br />

48 Fine Scissor 20<br />

49 Tuff scissor 10<br />

50<br />

Tracheostomy set (single<br />

puncture)<br />

51 Bone holding <strong>for</strong>cep(humerous)<br />

2<br />

52 Bone holding <strong>for</strong>cep(tibia) 1<br />

53 Bone holding <strong>for</strong>cep(Femur) 2<br />

54 Flexible fix head reamer no. 11<br />

1<br />

55 O2 Mask paed 5<br />

56<br />

laparoscopic trocar<br />

(versapotNo.10)<br />

2<br />

57<br />

laparoscopic trocar<br />

(versapotNo.12)<br />

2<br />

58 Maril<strong>and</strong> 2<br />

59 Laparoscopic bap Cock 4<br />

60 Laparoscopic alliz 2<br />

61 Monopolar cautry cord 50<br />

62 Bipolar Cautry (curved point) 2<br />

63 Formalin chamber big 2<br />

64 Formalin chamber smol 2<br />

65<br />

H<strong>and</strong> reamer 8 to 13<br />

(tibia/Femur)<br />

53<br />

1 set<br />

66 H<strong>and</strong> reamer 4 to 7 (Humurous)<br />

1set<br />

67 Punch 3


Sr. No Particulars Total Unit Rate Total<br />

68 Periosteum Small 2<br />

69 Periosteum Small Curved 2<br />

70 Periosteum Large 2<br />

71<br />

Intestinal clamp non crushing<br />

curved<br />

6<br />

72<br />

Intestinal clamp non crushing<br />

straigst<br />

6<br />

73 Bur per<strong>for</strong>ator <strong>for</strong> cramiotimy 1 set<br />

74 Reservoir bag 2 Ltr 5<br />

75 Reservoir bag 2.5 Ltr 5<br />

76 Turp loop (indian) 10<br />

77 Bain circuit <strong>for</strong> troley 5<br />

78 JRO circurt Paed 2<br />

79 Retrograbe Dialator 1<br />

80 Uretic cathetor fr. 3,4,5 2 each<br />

81 Double D. J .Stent Fr 3,4,5 2 each<br />

82 Sclero Therapy Needle 10<br />

83 Plier 5<br />

84<br />

Nibbler (Rounger) 30 Degree<br />

Bent<br />

5<br />

85 Nibbler (Rounger) Straigst 5<br />

86 Nibbler (Rounger) Large 5<br />

87 Nibbler (Rounger) Small 5<br />

88 Man Man Key 10<br />

89 Awl <strong>for</strong> tibia 2<br />

90 Awl <strong>for</strong> femur 2<br />

91 Awl Long H<strong>and</strong>el For femur 1<br />

92 Awl For Radius 2<br />

93 Blunt Disscetor 5<br />

94 Hammer <strong>for</strong> Ortho Small 2<br />

95 Hammer <strong>for</strong> Ortho Midium 2<br />

96 Hammer <strong>for</strong> Ortho heavy 2<br />

97 Homan Retractor 2 set<br />

98 T.H<strong>and</strong>le For K-Wire 5<br />

99 H<strong>and</strong> Dril 1<br />

100 Shanez Pin T. h<strong>and</strong>le 2<br />

101 Uterin Holding <strong>for</strong> ceps 3<br />

102 Deavers Medium Sige 5<br />

103 Tongue Deprassor 12<br />

104 Fistila Probe 5<br />

105 Mixtard 3 Pair


Sr. No Particulars Total Unit Rate Total<br />

106 Suprapubic Trocher 2<br />

107 Suctiom Tip Multipores 4 To 1<br />

2 Set<br />

108<br />

Scissor For Plastic Suragiry<br />

3"(metzenbaum)<br />

5<br />

109 Towel Clip 65<br />

110 Cannulated Screw Driver 4.5 2<br />

111 Cannulated Dril Bit 6.5 3<br />

112 Bone Marrow Needle no. 16 S.S<br />

113<br />

Small Size Spike For<br />

R/U/Humerous<br />

2 Set<br />

114<br />

Plate Holding Forceps<br />

R/U/Humerous<br />

1 Set<br />

115 Proseal LMA No. 3-4 2 Each<br />

116<br />

Combined Spinal 27G Epidural<br />

Needle16 G<br />

20<br />

117 Epidural needle 16G 10<br />

118 Epidural Catheter No.16 20<br />

119 Cord Holding For ceps 4<br />

Non scalpal Vasectomy NSV Hook 4 Each<br />

120 Vas Holding Forceps<br />

121 AO Drill Bit 3.5 3<br />

122 AO Drill Bit 4.5 3<br />

123 AO Drill Bit 2.5 3<br />

124 Counter synk 3.5 1<br />

125 Counter synk 4.5 1<br />

126 Acetabulum Retractor (all Sizes)<br />

127<br />

Wire cutter (Tumy Sleeve tip) For<br />

2 mm<br />

128<br />

Wire cutter (Tumy Sleeve tip) For<br />

5 mm<br />

1<br />

129 AO Tap 3.5 mm 1<br />

130 AO Tap 4.5 mm 1<br />

131<br />

Dissecting sleeve With Tumy<br />

Sleeve Tip<br />

3<br />

132 Bone Cutter Small 2<br />

133<br />

Bone Cutter Heavy<br />

2<br />

20<br />

1<br />

1


Sr. No Particulars Total Unit Rate Total<br />

134<br />

Osteotome set All Sizes With<br />

Wooden H<strong>and</strong>le (AO)<br />

1<br />

135 Adaptor For Suction (Steel) 2<br />

136 IDL Mirror 4<br />

137 Siegels Pneumetic Speculum 2<br />

138 T Elevator 8<br />

139 Mouth Mirror 45<br />

140 Upper Anterior <strong>for</strong>ceps 10<br />

141 Third Molar Forceps 9<br />

142 Hockey stick (Dental) 7<br />

143 Mouth Gag 3<br />

144 Magles <strong>for</strong>cep 6<br />

145 Nasal Speculun 5<br />

146 Plastic kidney tray (blue) 148<br />

147 IOL Manipulater( Blunt edge) 4<br />

148 Lim's tooth Forceps 5<br />

149 Plain <strong>for</strong>ceps (Opthalmic) 5<br />

150 Wire Vectis 4<br />

151 Phaco Choppper Sharp end 1<br />

152 Tunnel Knife 50<br />

153 Phaco Sleeve 5<br />

154 Phaco Tubing Set 2<br />

155 Keratoplasty set 1<br />

156 Diamond knipe 1<br />

157 Endocapsuler Tension Rings 10<br />

158 Iris Hook (self Retaining) 4<br />

159 Silicon Sling <strong>for</strong> Ptosis 5<br />

160 Rhexcis Forceps 2<br />

161 Vitrectomy cutter 1<br />

162 Glass Syringe 10 ml,5ml,2ml 20 each<br />

163 AC Maintainer 5<br />

164<br />

165<br />

V P Shunt Introducer (Adult)<br />

All Size<br />

V P Shunt Introducer (Paed)<br />

All Size<br />

The above mentioned rates are including all freight & taxes.<br />

Sign:<br />

Stamp:<br />

1<br />

1