VAN-115/230AC-K13-EFD<br />

Masters and<br />

Gateways<br />

Power Supplies,<br />

Extender, Repeaters<br />

Safety at work<br />

I/O Modules<br />

Control cabinet<br />

I/O Modules<br />

Field application<br />

Analogue modules<br />

Other modules<br />

Inductive sensors<br />

Photoelectric<br />

sensors<br />

Rotary encoders<br />

Accessories<br />

<strong>AS</strong>-<strong>Interface</strong> power supply<br />

Order code<br />

VAN-115/230AC-K13-EFD<br />

<strong>AS</strong>-<strong>Interface</strong> power supply<br />

Features<br />

62<br />

<strong>AS</strong>-<strong>Interface</strong> certificate<br />

PELV<br />

LED operating display<br />

2.4 A output load<br />

115 V AC to 230 V AC<br />

<strong>AS</strong>-<strong>Interface</strong> filter integrated<br />

Power factor correction<br />

Earh fault detection<br />

Dimensions<br />

135<br />

Electrical connection<br />

L<br />

N<br />

PE<br />

Indicating/operating means<br />

N<br />

L<br />

Reset<br />

LED-EFD<br />

LED-Dc o.k.<br />

<strong>AS</strong>-<strong>Interface</strong> +<br />

GND<br />

<strong>AS</strong>-<strong>Interface</strong> -<br />

13(+)<br />

14<br />

60 110<br />

VAN-115/230AC-K13-EFD<br />

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany<br />

Pepperl+Fuchs Group Tel.: Germany +49 621 776-0 USA +1 330 4253555 Singapore +65 67799091 Internet http://www.pepperl-fuchs.com<br />

EFD<br />

EFD<br />

D<br />

A<br />

T<br />

A<br />

D<br />

E<br />

C<br />

O<br />

U<br />

P<br />

L<br />

I<br />

N<br />

G<br />

<strong>AS</strong>-<strong>Interface</strong> +<br />

GND<br />

<strong>AS</strong>-<strong>Interface</strong> -<br />

13 (+)<br />

EFD<br />

switch<br />

output<br />

14<br />

Auxiliary Power<br />

+ -<br />

Reset button<br />

Press briefly (< 2 sec.) - Earth fault simulation<br />

Press long (> 2 sec.) - Reset of earth fault indication<br />

EFD-switch output<br />

Earth fault detection-selector switch<br />

EFD ext. - Earth fault only signalled<br />

EFD int. - Earth fault switches off power pack<br />

Issue date 2004-11-19 - Catalogue <strong>AS</strong>-<strong>Interface</strong> 2004/2005