Issue date 2004-11-19 - Catalogue <strong>AS</strong>-<strong>Interface</strong> 2004/2005<br />
<strong>AS</strong>-<strong>Interface</strong> gateway<br />
Technical data<br />
General specifications<br />
<strong>AS</strong>-<strong>Interface</strong> specification<br />
Indicators/operating means<br />
V2.11<br />
LED display, two-digit address display, error message<br />
LED BUS ACTIVE PROFIBUS master detected; LED green<br />
LED <strong>AS</strong>-i ACTIVE <strong>AS</strong>-<strong>Interface</strong> operation normal; LED green<br />
LED CONFIG ERR configuration error; LED red<br />
LED PRG ENABLE autom. programming; LED green<br />
LED ENERGY voltage ON; LED green<br />
LED PRJ MODE projecting mode active; LED yellow<br />
LED U <strong>AS</strong>-i <strong>AS</strong>-<strong>Interface</strong> voltage; LED green<br />
Switch SET Selection and setting of a slave address<br />
Button MODE<br />
Electrical specifications<br />
Mode selection/save configuration<br />
Insulation voltage Ui ≥ 500 V<br />
Rated operational voltage Ue from <strong>AS</strong>-<strong>Interface</strong><br />
Rated operational current Ie ≤ 180 mA from <strong>AS</strong>-<strong>Interface</strong><br />
<strong>Interface</strong><br />
Protocol PROFIBUS<br />
<strong>Interface</strong> type RS 485<br />
Transfer rate<br />
Connection<br />
9.6 kBit/s ... 12 MBit/s self-synchronising<br />
PROFIBUS Cable gland M16 x 1.5 and cage spring terminals<br />
<strong>AS</strong>-<strong>Interface</strong><br />
Ambient conditions<br />
cable piercing technique<br />
Ambient temperature 0 ... 55 °C (273 ... 328 K)<br />
Storage temperature<br />
Mechanical specifications<br />
-25 ... 85 °C (248 ... 358 K)<br />
Protection degree IP65 according to EN 60529<br />
Mass approx. 355 g<br />
Software<br />
The device is supplied with the configuration data files (GSD) as well as a restricted version of<br />
the <strong>AS</strong>-i Control Tools software. The software performs the addressing, programming and<br />
monitoring of the <strong>AS</strong>-<strong>Interface</strong> network. The full version of the <strong>AS</strong>-i Control Tool is available<br />
as an accessory and features an expanded diagnostics monitor as well as a larger program<br />
memory for <strong>AS</strong>-<strong>Interface</strong> Control which makes it possible to detect faulty telegrams of slaves.<br />
A GSD file can be easily created for the PROFIBUS DP using the GSD assistant, whereby<br />
the size of the I/O windows can be conveniently adapted to the <strong>AS</strong>-<strong>Interface</strong> circuit's load and<br />
the <strong>AS</strong>-<strong>Interface</strong> configuration can be stored within the GSD file. A text file is also created,<br />
which documents the status of <strong>AS</strong>-<strong>Interface</strong> data in the gateway's I/O window.<br />
Note:<br />
The VAZ-PB-SIM accessory is required for the <strong>AS</strong>-i Control Tool.<br />
Function<br />
VBG-PB-G4F-R4<br />
The VBG-PB-G4F-R4 is a complete PROFI-<br />
BUS slave with an IP67 rating designed for<br />
use in the field. The G4 field housing of the<br />
PROFIBUS gateway offers all the advantages<br />
of the serial master in this design.<br />
The VBG-PB-G4F-R4 is a modular PROFI-<br />
BUS slave. This means that the user can use<br />
the PROFIBUS configuration tool to specify<br />
what data will be transferred via the PROFI-<br />
BUS. This makes it possible to adjust the<br />
amount of data to be transferred via PROFI-<br />
BUS.<br />
In addition, this gateway supports acyclical<br />
communication of the PROFIBUS DP V1.<br />
These acyclical services can be used to<br />
access a mailbox in the gateway that provide<br />
access to all the data that are made available<br />
by the <strong>AS</strong>-<strong>Interface</strong>/PROFIBUS Gateway.<br />
Two push buttons are used for address<br />
assignment, acceptance of the desired configuration<br />
and for adjustment of the PROFI-<br />
BUS address and baud rate. In configuration<br />
mode, all detected <strong>AS</strong>-<strong>Interface</strong> slaves are<br />
displayed on the 2-digit LCD. In normal operation,<br />
the LCD is blank unless the master<br />
detects a faulty <strong>AS</strong>-<strong>Interface</strong> slave. There are<br />
7 LEDs on the front panel, showing the current<br />
status of the <strong>AS</strong>-<strong>Interface</strong> line.<br />
Accessories<br />
VAZ-SW-ACT32<br />
Full version of the <strong>AS</strong>-i Control Tools<br />
VAZ-PB-SIM<br />
PROFIBUS master simulator<br />
VAZ-G4-R4<br />
<strong>Interface</strong> cable for direct connection of<br />
the master to a PC<br />
U-G1P<br />
Base for connection to round cable<br />
(EMS;<br />
<strong>AS</strong>-<strong>Interface</strong> only)<br />
VAZ-G4-B<br />
Blind plug PG7<br />
Note<br />
U-G1F<br />
base is included with delivery<br />
Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany<br />
Pepperl+Fuchs Group Tel.: Germany +49 621 776-0 USA +1 330 4253555 Singapore +65 67799091 Internet http://www.pepperl-fuchs.com 39<br />
Masters and<br />
Gateways<br />
Power Supplies,<br />
Extender, Repeaters<br />
Safety at work<br />
I/O Modules<br />
Control cabinet<br />
I/O Modules<br />
Field application<br />
Analogue modules<br />
Other modules<br />
Inductive sensors<br />
Photoelectric<br />
sensors<br />
Rotary encoders<br />
Accessories